Skip to main content

Advertisement

Log in

Precision luminosity for Z\(^0\) lineshape measurements with a silicon-tungsten calorimeter

  • Experimental physics
  • Published:
The European Physical Journal C - Particles and Fields Aims and scope Submit manuscript

Abstract.

The measurement of small–angle Bhabha scattering is used to determine the luminosity at the OPAL interaction point for the LEP I data recorded between 1993 and 1995. The measurement is based on the OPAL Silicon-Tungsten Luminometer which is composed of two calorimeters encircling the LEP beam pipe, on opposite sides of the interaction point. The luminometer detects electrons from small–angle Bhabha scattering at angles between 25 and 58 mrad. At LEP center-of-mass energies around the Z\(^0\), about half of all Bhabha electrons entering the detector fall within a 79 nb fiducial acceptance region. The electromagnetic showers generated in the stack of 1 radiation length tungsten absorber plates are sampled by 608 silicon detectors with 38,912 radial pads of 2.5 mm width. The fine segmentation of the detector, combined with the precise knowledge of its physical dimensions, allows the trajectories of incoming 45 GeV electrons or photons to be determined with a total systematic error of less than 7 microns. We have quantified all significant sources of systematic experimental error in the luminosity determination by direct physical measurement. All measured properites of the luminosity event sample are found to be in agreement with current theoretical expectations. The total systematic measurement uncertainty is \(3.4 \times 10^{-4}\), significantly below the theoretical error of \(5.4 \times 10^{-4}\) currently assigned to the QED calculation of the Bhabha acceptance, and contributes negligibly to the total uncertainty in the OPAL measurement of \(\Gamma_{\rm inv}/ \Gamma_{\ell^+\ell^-}\), a quantity of basic physical interest which depends crucially on the luminosity measurement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Consortia

Additional information

Received: 28 September 1999 / Published online: 14 April 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

The OPAL Collaboration., Abbiendi et al., G. Precision luminosity for Z\(^0\) lineshape measurements with a silicon-tungsten calorimeter. Eur. Phys. J. C 14, 373–425 (2000). https://doi.org/10.1007/s100520000353

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s100520000353

Keywords

Navigation