Abstract

Background

As the anatomical three-dimensional (3D) positional relationship around the anterior clinoid process (ACP) is complex, experience of many surgeries is necessary to understand anterior clinoidectomy (AC). We prepared a 3D synthetic image from computed tomographic angiography (CTA) and magnetic resonance imaging (MRI) data and a rapid prototyping (RP) model from the imaging data using a 3D printer. The objective of this study was to evaluate anatomical reproduction of the 3D synthetic image and intraosseous region after AC in the RP model. In addition, the usefulness of the RP model for operative simulation was investigated.

Methods

The subjects were 51 patients who were examined by CTA and MRI before surgery. The size of the ACP, thickness and length of the optic nerve and artery, and intraosseous length after AC were measured in the 3D synthetic image and RP model, and reproducibility in the RP model was evaluated. In addition, 10 neurosurgeons performed AC in the completed RP models to investigate their usefulness for operative simulation.

Results

The RP model reproduced the region in the vicinity of the ACP in the 3D synthetic image, including the intraosseous region, at a high accuracy. In addition, drilling of the RP model was a useful operative simulation method of AC.

Conclusions

The RP model of the vicinity of ACP, prepared using a 3D printer, showed favorable anatomical reproducibility, including reproduction of the intraosseous region. In addition, it was concluded that this RP model is useful as a surgical education tool for drilling.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Choi JY, Choi JH, Kim NK, Kim Y, Lee JK, Kim MK, Lee JH, Kim MJ (2002) Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg 31:23–32

    Article  CAS  PubMed  Google Scholar 

  2. Csókay A, Papp A, Imreh D, Czabajszky M, Valálik I, Antalfi B (2013) Modelling pathology from autolog fresh cadaver organs as a novel concept in neurosurgical training. Acta Neurochir (Wien) 155:1993–1995

    Article  Google Scholar 

  3. Dagtekin A, Avci E, Uzmansel D, Kurtoglu Z, Kara E, Uluc K, Akture E, Baskaya MK (2014) Microsurgical anatomy and variations of the anterior clinoid process. Turk Neurosurg 24:484–493

    PubMed  Google Scholar 

  4. Dolenc VV (1985) A combined epi- and subdural direct approach to carotid-ophthalmic artery aneurysms. J Neurosurg 62:667–672

    Article  CAS  PubMed  Google Scholar 

  5. Harada N, Kondo K, Miyazaki C, Nomoto J, Kitajima S, Nemoto M, Uekusa H, Harada M, Sugo N (2011) Modified three-dimensional brain model for study of the trans-sylvian approach. Neurol Med Chir (Tokyo) 51:567–571

    Article  Google Scholar 

  6. Huotilainen E, Jaanimets R, Valášek J, Marcián P, Salmi M, Tuomi J, Mäkitie A, Wolff J (2014) Inaccuracies in additive manufactured medical skull models caused by the DICOM to STL conversion process. J Craniomaxillofac Surg 42:259–265

    Article  Google Scholar 

  7. Kondo K, Nemoto M, Masuda H, Okonogi S, Nomoto J, Harada N, Sugo N, Miyazaki C (2015) Anatomical reproducibility of a head model molded by a three-dimensional printer. Neurol Med Chir (Tokyo) 55:592–598

    Article  Google Scholar 

  8. Kondo K, Harada N, Masuda H, Sugo N, Terazono S, Okonogi S, Sakaeyama Y, Fuchinoue Y, Ando S, Fukushima D, Nomoto J, Nemoto M (2016) A neurosurgical simulation of skull base tumors using a 3D printed rapid prototyping model containing mesh structures. Acta Neurochir (Wien) 158:1213–1219

    Article  Google Scholar 

  9. Konno T, Mashiko T, Oguma H, Kaneko N, Otani K, Watanabe E (2016) Rapid 3-dimensional models of cerebral aneurysm for emergency surgical clipping. No Shinkei Geka 44:651–660

    PubMed  Google Scholar 

  10. Kulwin C, Tubbs RS, Cohen-Gadol AA (2011) Anterior clinoidectomy: description of an alternative hybrid method and a review of the current techniques with an emphasis on complication avoidance. Surg Neurol Int 2:140

    Article  PubMed  PubMed Central  Google Scholar 

  11. Lehmberg J, Krieg SM, Meyer B (2014) Anterior clinoidectomy. Acta Neurochir (Wien) 156:415–419

    Article  CAS  Google Scholar 

  12. Mashiko T, Otani K, Kawano R, Konno T, Kaneko N, Ito Y, Watanabe E (2015) Development of three-dimensional hollow elastic model for cerebral aneurysm clipping simulation enabling rapid and low cost prototyping. World Neurosurg 83:351–361

    Article  PubMed  Google Scholar 

  13. Matsushima T, Kawashima M, Matsushima K, Wanibuchi M (2015) Japanese neurosurgeons and microsurgical anatomy: a historical review. Neurol Med Chir (Tokyo) 55:276–285

    Article  Google Scholar 

  14. Oishi M, Fukuda M, Yajima N, Yoshida K, Takahashi M, Hiraishi T, Takao T, Saito A, Fujii Y (2013) Interactive presurgical simulation applying advanced 3D imaging and modeling techniques for skull base and deep tumors. J Neurosurg 119:94–105

    Article  PubMed  Google Scholar 

  15. Olszewski R, Szymor P, Kozakiewicz M (2014) Accuracy of three-dimensional, paper-based models generated using a low-cost, three-dimensional printer. J Craniomaxillofac Surg 42:1847–1852

    Article  PubMed  Google Scholar 

  16. Pluim JP, Maintz JB, Viergever MA (2000) Image registration by maximization of combined mutual information and gradient information. IEEE Trans Med Imaging 19:809–814

    Article  CAS  PubMed  Google Scholar 

  17. Sai Kiran NA, Furtado SV, Hegde AS (2013) How I do it: anterior clinoidectomy and optic canal unroofing for microneurosurgical management of ophthalmic segment aneurysms. Acta Neurochir (Wien) 155:1025–1029

    Article  Google Scholar 

  18. Son HE, Park MS, Kim SM, Jung SS, Park KS, Chung SY (2010) The avoidance of microsurgical complications in the extradural anterior clinoidectomy to paraclinoid aneurysms. J Korean Neurosurg Soc 48:199–206

    Article  PubMed  PubMed Central  Google Scholar 

  19. Spektor S, Dotan S, Mizrahi CJ (2013) Safety of drilling for clinoidectomy and optic canal unroofing in anterior skull base surgery. Acta Neurochir (Wien). 155:1017–1024

    Article  PubMed  Google Scholar 

  20. Sumida M, Arita K, Migita K, Iida K, Kurisu K, Uozumi T (1998) Demonstration of the optic pathway in sellar/juxtasellar tumours with visual disturbance on MR imaging. Acta Neurochir (Wien) 140:541–548

    Article  CAS  Google Scholar 

  21. Suri A, Patra DP, Meena RK (2016) Simulation in neurosurgery: past, present, and future. Neurol India 64:387–395

    Article  PubMed  Google Scholar 

  22. Tai BL, Rooney D, Stephenson F, Liao PS, Sagher O, Shih AJ, Savastano LE (2015) Development of a 3D-printed external ventricular drain placement simulator: technical note. J Neurosurg 123:1070–1076

    Article  PubMed  Google Scholar 

  23. Vakharia VN, Vakharia NN, Hill CS (2016) Review of 3-dimensional printing on cranial neurosurgery simulation training. World Neurosurg 88:188–198

    Article  PubMed  Google Scholar 

  24. Watanabe K, Kakeda S, Yamamoto J, Watanabe R, Nishimura J, Ohnari N, Nishizawa S, Korogi Y (2012) Delineation of optic nerves and chiasm in close proximity to large suprasellar tumors with contrast-enhanced FIESTA MR imaging. Radiology 264:852–858

    Article  PubMed  Google Scholar 

  25. Yokoi T, Soma T, Shinohara H, Matsuda H (2004) Accuracy and reproducibility of co-registration techniques based on mutual information and normalized mutual information for MRI and SPECT brain images. Ann Nucl Med 18:659–667

    Article  PubMed  Google Scholar 

  26. Yonekawa Y, Ogata N, Imhof HG, Olivecrona M, Strommer K, Kwak TE, Roth P, Groscurth P (1997) Selective extradural anterior clinoidectomy for supra- and parasellar processes. J Neurosurg 87:636–642

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Chiaki Nishimura, PhD, Professor Emeritus of Toho University, for helping us with the statistical processing. We also thank Kazuhiro Tachiki, RT, at Toho University Medical Center for molding the RP models in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shinichi Okonogi.

Ethics declarations

This article does not contain any studies with human participants performed by any of the authors.

Funding

No funding was received for this research.

Conflicts of interest

All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers’ bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or nonfinancial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Okonogi, S., Kondo, K., Harada, N. et al. Operative simulation of anterior clinoidectomy using a rapid prototyping model molded by a three-dimensional printer. Acta Neurochir 159, 1619–1626 (2017). https://doi.org/10.1007/s00701-017-3202-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00701-017-3202-4

Key word

Navigation