Summary
We report a patient with bow hunter’s syndrome who was treated by anterior decompression of the vertebral artery (VA) using an ultrasonic bone curette (SONOPET). This 60-year-old man reported almost losing consciousness upon head rotation. Although the right VA appeared normal at the natural head position, upon left head rotation it became completely occluded at the transverse foramen of C2. We performed anterior decompression of the right VA at the axis using a high-speed drill and SONOPET. For anterior decompression of the VA in a deep and narrow operative field, we recommend use of SONOPET, which permits safe, easy bone dissection.
References
MW Fox DG Piepgras JD Bartleson (1995) ArticleTitleAnterolateral decompression of the atlanto-axial vertebral artery for symptomatic positional occlusion of the vertebral artery. Case report J Neurosurg 83 737–740 Occurrence Handle7674027 Occurrence Handle1:STN:280:DyaK2MvgsVeiuw%3D%3D
J Hanakita H Miyake S Nagayasu S Nishi T Suzuki (1988) ArticleTitleAngiographic examination and surgical treatment of bow hunter’s stroke Neurosurgery 23 228–232 Occurrence Handle3185883 Occurrence Handle10.1097/00006123-198808000-00018 Occurrence Handle1:STN:280:DyaL1M%2FktVGitw%3D%3D
K Kim T Isu R Matsumoto M Isobe K Kogure (2006) ArticleTitleSurgical pitfalls of an ultrasonic bone curette (SONOPET) in spinal surgery Neurosurgery 59 ONS390-3
T Matsuyama T Morimoto T Sakaki (1997) ArticleTitleComparison of C1–2 posterior fusion and decompression of the vertebral artery in the treatment of bow hunter’s stroke J Neurosurg 86 619–623 Occurrence Handle9120624 Occurrence Handle1:STN:280:DyaK2s3jsVWgtw%3D%3D Occurrence Handle10.3171/jns.1997.86.4.0619
H Nakagawa SD Kim J Mizuno Y Ohara K Ito (2005) ArticleTitleTechnical advantages of an ultrasonic bone curette in spinal surgery J Neurosurg Spine 2 431–435 Occurrence Handle15871482
T Seki K Hida M Akino Y Iwasaki (2001) ArticleTitleAnterior decompression of the atlanto-axial vertebral artery to treat bow hunter’s stroke: Technical case report Neurosurgery 49 1474–1476 Occurrence Handle11859829 Occurrence Handle10.1097/00006123-200112000-00037 Occurrence Handle1:STN:280:DC%2BD387isVamtQ%3D%3D
T Shimizu S Waga T Kojima S Niwa (1988) ArticleTitleDecompression of the vertebral artery for bow-hunter’s stroke. Case report J Neurosurg 69 127–131 Occurrence Handle3379466 Occurrence Handle1:STN:280:DyaL1c3ksVyjsg%3D%3D
BF Sorensen (1978) ArticleTitleBow hunter’s stroke Neurosurgery 2 259–261 Occurrence Handle732978 Occurrence Handle10.1097/00006123-197805000-00013 Occurrence Handle1:STN:280:DyaE1M%2FpsVaisg%3D%3D
Author information
Authors and Affiliations
Corresponding author
Additional information
None of the authors has any financial agreements or relationships with Miwatec Co. Ltd., Kawasaki, Japan, the manufacturer of the SONOPET. None of the authors is, or has been, an employee of Miwatec, and none collaborated in the design of the instrument. We purchased the instruments used through the regular purchasing channels of our institute.
Correspondence: Kyongsong Kim, M.D., Department of Neurosurgery, Chiba Hokuso Hospital, Nippon Medical School, 1715 Kamagari, Inba, Chiba, Japan.
Rights and permissions
About this article
Cite this article
Kim, K., Isu, T., Morimoto, D. et al. Anterior vertebral artery decompression with an ultrasonic bone curette to treat bow hunter’s syndrome. Acta Neurochir (Wien) 150, 301–303 (2008). https://doi.org/10.1007/s00701-008-1491-8
Received: