Skip to main content
Log in

Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management?

  • Neonatal and Pediatric Intensive Care
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Objective: Transoesophageal Doppler (TOD) has been used in adults to optimise left ventricular filling on the basis of the waveform parameters. We wished to see if a similar relationship exists in children, specifically: (a) whether change in thermodilution stroke volume (SV) following a fluid bolus corresponded to change in Doppler stroke distance, Doppler corrected flow time (FTc), or central venous pressure (CVP); (b) whether a response to fluid challenge (defined as an increase in SV of greater than 10%) can be predicted on the basis of an absolute value for FTc or CVP prior to fluid bolus; and (c) the relationship between FTc and systemic vascular resistance index. Design: Prospective, comparison study. Setting: Sixteen-bed paediatric intensive care unit of a university hospital. Patients: Ninety-four ventilated children were studied, median (range) age 25 months (4 days–16 years). Diagnoses included: post-cardiac surgery (n=58), sepsis/multi-organ failure (n=29), respiratory disease (n=5), and other (n=2). Interventions: A 4-MHz, 5.5-mm diameter, flexible TOD probe was placed when patients were haemodynamically stable. Five consecutive measurements of stroke distance and FTc were made and averaged, concurrently with five SV measurements by femoral artery thermodilution. SV was then augmented by administration of fluid (10 ml/kg), and haemodynamic recordings were repeated. Measurements and main results: The median (range) SV was 17 ml (2–64 ml). The median coefficients of variation were 3.9% for SV, 3.5% for stroke distance, and 3.1% for FTc. Changes in SV were accurately tracked by changes in stroke distance (mean bias1.8%, limits of agreement±17%), but not by FTc or CVP. FTc was weakly inversely correlated with systemic vascular resistance (r=–0.15, P<0.05). Among non-cardiac patients (n=36), the optimal FTc that predicted an improvement in SV following fluid bolus was 0.394 s (area under ROC curve 0.756), giving a sensitivity of 90%, specificity of 62%, positive predictive value of 47%, and a negative predictive value of 94%. CVP was a poor predictor for all patient groups. Conclusions: TOD stroke distance is able to follow changes in SV following fluid bolus amongst ventilated children, and can predict when further volume loading is unlikely to improve SV amongst general, but not cardiac ICU patients. CVP is a poor discriminator of volume status in this group of patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Final revision received: 6 September 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tibby, S., Hatherill, M., Durward, A. et al. Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management?. Intensive Care Med 27, 201–205 (2001). https://doi.org/10.1007/s001340000795

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001340000795

Navigation