Abstract
Two of the Poisson's ratio compliances have been determined for oriented polyethylene terephthalate (PET) sheet. The method adopted was to determine the fringe shift under load when the specimens were placed in one arm of a Michelson interferometer operating in a vertical fringe mode. Data obtained for the specimens in air and in a water bath, with two polarization directions, can be used to provide two independent measurements of each compliance. Good agreement was shown between these measurements, and the values for the compliance constants are reasonable on physical grounds, as well as being consistent with previous work on PET fibres.
Similar content being viewed by others
References
M. W. Darlington andD. W. Saunders,J. Phys. E. 3 (1970) 511.
Idem, J. Phys. D. 3 (1970) 535.
D. Clayton, M. W. Darlington andM. M. Hall,J. Phys. E. 6 (1973) 218.
N. H. Ladizesky andI. M. Ward,J. Macromol. Sci. Phys. B5 (1971) 661.
V. Davis,J. Text. Inst. 50 (1960) 1688.
F. I. Frank andA. L. Ruoff,Text. Res. J. 28 (1958) 213.
D. W. Hadley, I. M. Ward andJ. Ward,Proc. Roy. Soc. A285, (1965) 275.
P. R. Pinnock, I. M. Ward andJ. M. Wolfe,ibid. A291 (1966) 267.
D. W. Hadley, P. R. Pinnock andI. M. Ward,J. Mater. Sci. 4 (1969) 152.
N. H. Ladizesky andI. M. Ward,ibid. 8 (1973) 980.
M. Kashiwagi, A. Cunningham, A. J. Manuel andI. M. Ward,Polymer 14, (1973) 111.
J. F. Nye, “Physical Properties of Crystals” (Clarendon Press, Oxford, 1957).
I. Wilson, N. H. Ladizesky andI. M. Ward J. Mater. Sci. 11 (1976) 2177.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wilson, I., Cunningham, A. & Ward, I.M. The determination of Poisson's ratio compliances for polyethylene terephthalate sheets using a Michelson interferometer. J Mater Sci 11, 2181–2188 (1976). https://doi.org/10.1007/BF00752081
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00752081