Abstract
An electrooptical sensor for the detection of muscle contraction is described. Infrared light is injected into the muscle, the backscattering is observed, and the contraction is detected by measuring the change, that occurs during muscle contraction, between the light scattered in the direction parallel and perpendicular to the muscle cells. With respect to electromyography and to optical absorption-based sensors, our device has the advantage of lower invasiveness, of lower sensitivity to electromagnetic noise and to movement artifacts, and of being able to distinguish between isometric and isotonic contractions.
References
Andreasen LNS, Struijk UJJ (2003) Artefact reduction with alternative cuff configurations. IEEE Trans Biomed Eng 50:1160–1166
Bianchi T, Zambarbieri D, Beltrami G, Verni G (1999) NIRS monitoring of muscle contraction to control a prosthetic device. SPIE Proc 3570:157–163
Fomenko VN, Shwarts FM, Shwarts MA (1998) Exact description of the photon migration in anisotropically scattering media. SPIE Proc 3566:47–56
Gelmetti A, Giardini ME, Lago P, Pavesi R, Zambarbieri D, Maestri R, Felicetti G (1997) Preliminary study of muscle contraction assessment by NIR spectroscopy. SPIE Proc 3199:61–67
Lai JCK, Schoen MP, Gracia AP, Naidu DS, Leung SW (2007) Prosthetic devices: challenges and implications of robotic implants and biological interfaces. Proc Inst Mech Eng H—J Eng Med 221:173–183
Lopez NM, di Sciascio F, Soria CM, Valentinuzzi ME (2009) Robust EMG sensing system based on data fusion for myoelectric control of a robotic arm. Biomed Eng Online 8: Art. No. 5
Merletti R, Parker PA (eds) (2004) Electromyography: physiology, engineering and noninvasive applications. Wiley-IEEE, USA
Parker P, Englehart K, Hudgins B (2006) Myoelectric signal processing for control of powered limb prostheses. J Electromyogr Kinesiol 16:541–548
Reaz MBI, Hussain MS, Mohd-Yasin F (2006) Techniques of EMG signal analysis: detection, processing, classification and applications. Biol Proced Online 8:11–35
Sood A, Taylor JS, Billock JN (2003) Contact dermatitis to a limb prosthesis. Am J Contact Dermat 14:169–171
Tuchin V (2000) Tissue optics. SPIE Publishing, USA
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Chianura, A., Giardini, M.E. An electrooptical muscle contraction sensor. Med Biol Eng Comput 48, 731–734 (2010). https://doi.org/10.1007/s11517-010-0626-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-010-0626-x