Skip to main content
Log in

234U and 238U in mineral water: reference value and uncertainty evaluation in the frame of an interlaboratory comparison

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

In 2007/2008 the Institute for Reference Materials and Measurements (IRMM) organised an interlaboratory comparison (ILC) on the determination of 226Ra, 228Ra, 234U and 238U activity concentrations in mineral water. This paper describes the determination of the reference values for the activity concentrations of 234U and 238U by radiochemical separation and α-particle spectrometry performed at two independent laboratories. The experimental uncertainty of the reference values is discussed in detail.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. ISO: International Standard ISO 13528, Statistical methods for use in proficiency testing by interlaboratory comparisons. Geneva, Switzerland (2005)

  2. Der Bundesminister für Umwelt: Naturschutz und Reaktorsicherheit: „Messanleitungen für die Überwachung der Radioaktivität in der Umwelt und zur Erfassung radioaktiver Emissionen aus kerntechnischen Anlagen”. Elsevier-Urban & Fischer Verlag, Lieferungen 1 – 7, Stand 2006, ISBN 3-437-11456-5 und ISBN 3-437-21599-x

  3. Horwitz, E.P., Chiarizia, R., Dietz, M.L., Diamond, H.: Separation and preconcentration of actinides from acidic media by extraction chromatography. Anal. Chim. Acta 281, 361–372 (1993)

    Article  CAS  Google Scholar 

  4. Benedik, L., Spasova, Y., Vasile, M., Wätjen, U.: Determination of 234U, 238U and 226Ra in bottled drinking water by alpha spectrometry. CD Proceedings of the 7th International Conference on Nuclear and Radiochemistry (NRC-7), Budapest, Hungary, 24–29 August 2008

  5. Sill, C.W., Williams, R.L.: Preparation of actinides for alpha spectrometry without electrodeposition. Anal. Chem. 53, 415–421 (1981)

    Article  Google Scholar 

  6. Sibbens, G., Pommé, S., Altzitzoglou, T.: Standardisation of low-activity actinide solutions by alpha-particle counting at a defined solid angle. Appl. Radiat. Isot. 61, 405–408 (2004)

    Article  CAS  Google Scholar 

  7. ISO/IEC: ISO Guide 43-1, Proficiency testing by interlaboratory comparisons. Part I: Development and operation of proficiency testing schemes. Geneva, Switzerland (1997)

  8. Pommé, S., Spasova, Y.: A practical procedure for assigning a reference value and uncertainty in the frame of an interlaboratory comparison. Accred. Qual. Assur. 13, 83–89 (2008)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Y. Spasova.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Spasova, Y., Benedik, L., Vasile, M. et al. 234U and 238U in mineral water: reference value and uncertainty evaluation in the frame of an interlaboratory comparison. J Radioanal Nucl Chem 281, 113–117 (2009). https://doi.org/10.1007/s10967-009-0069-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-009-0069-8

Keywords

Navigation