Presentation of Laboratory and Sonoclot Variables Using Principal Component Analysis: Identification of Hypo- and Hypercoagulation in the Hellp Syndrome

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

The HELLP (Hemolysis, Elevated Liver enzyme, and Low Platelet) syndrome requires close monitoring of rapid changes in hemostasis. A bedside viscoelastic test – Sonoclot – was used together with coagulation, liver and hemolysis laboratory analyses in three parturients with the HELLP syndrome up to 10 days postpartum. Principal component analysis (PCA) was used to reduce the dimensionality of this multivariate problem and to visualize this process in a two-dimensional plot. It was possible to follow changes in these variables over time and to show how they changed in relation to 10 typical healthy parturients with normal laboratory and Sonoclot values as well as 20 simulated patients with hypo- or hypercoagubility. The effects of emergency delivery, correction of low plasma-antithrombin with plasma and antithrombin factor concentrate, plasma exchange and individualized dosages of low molecular weight heparin to counteract postpartum Sonoclot detected hypercoagulation were evaluated. The efficiency of each treatment strategy was visualized in the PCA plot by movement towards an area with normocoagulation. In conclusion, PCA of viscoelastic and laboratory coagulation analysis data facilitated the detection of both hypo- and hypercoagulative events and represents an alternative way to evaluate treatment strategies in patients with complex coagulative disorders, like the HELLP syndrome.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sibai BM, Ramadan MK, Usta I, et al, Maternal morbidity and mortality in 442 pregnancies with hemolysis, elevated liver enzymes, and low platelets (HELLP syndrome). Am J Obstet Gynecol 1993; 169: 1000–1063.

    Google Scholar 

  2. Fish R, The HELLP syndrome: Case report and review of the literature. J Emerg Med 1993; 11: 169–174.

    Google Scholar 

  3. Stevenson JT, Graham DJ, Hepatic hemorrhage and the HELLP syndrome: A surgeon’s perspective. Am Surgeon 1995; 61: 756–760.

    Google Scholar 

  4. Barton JR, Riely CA, Adamec TA, et al, Hepatic histopathology condition does not correlate with laboratory abnormalities in HELLP syndrome (hemolysis elevated liver enzymes, and low platelet count). Am J Obstet Gynecol 1992; 167: 1538-1543.

    Google Scholar 

  5. Steer PL, Krantz HB, Thromboelastography and Sonoclot analysis in the healthy parturient. J Clin Anesth 1993; 5: 419–424.

    Google Scholar 

  6. Whitta RK, Cox DJ, Mallet SV, Thrombelastography reveals two causes of haemorrhage in HELLP syndrome. Br J Anaesth 1995; 74: 464–468.

    Google Scholar 

  7. Wong CA, Liu S, Glassenberg R, Comparison of thrombelastography with common coagulation tests in preeclamptic and healthy parturients. Reg Anesth 1995; 20: 521–527.

    Google Scholar 

  8. Orlikowski CEP, Rocke DA, Murray WB et al, Thrombelastography changes in pre-eclampsia and eclampsia. Br J Anesth 1996; 77: 157–161.

    Google Scholar 

  9. Steer PL, Finley BE, Blumenthal LA, Abruptio placentae and disseminated intravascular coagulation: Use of thrombelastography and sonoclot analysis. Int J Obstet Anesth 1994; 3: 229-233.

    Article  PubMed  Google Scholar 

  10. Kjellberg U, Hellgren M, Sonoclot signature during normal pregnancy. Int Care Med 2000; 26: 206–211.

    Article  Google Scholar 

  11. Meherg L, Jeffrey B, Riley BA, Wolk DR, Do sonoclot coagulation parameters correlate with thromboelastograph parameters. J Extra-Corp Tech 1993; 24: 145–151.

    Google Scholar 

  12. Chatfield C, Introduction to multivariate analysis. London: Chapman & Hall, 1992.

    Google Scholar 

  13. Liszka-Hackzell J, Ekback G, Analysis of the information content in sonoclot data and reconstruction of coagulation test variables. J Med Syst 2002; 26: 1–8.

    Article  PubMed  Google Scholar 

  14. Romeo M, Burden F, Quinn M, Wood B, McNaughton D, Infrared microspectroscopy and artificial neural networks in the diagnosis of cervical cancer. Cell Mol Biol 1998; 44(1): 179–187.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to John J. Liszka-Hackzell MD, PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Liszka-Hackzell, J.J., Schött, U. Presentation of Laboratory and Sonoclot Variables Using Principal Component Analysis: Identification of Hypo- and Hypercoagulation in the Hellp Syndrome. J Clin Monit Comput 18, 247–252 (2004). https://doi.org/10.1007/s10877-005-9046-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-005-9046-0

Keywords

Navigation