Abstract
Multiple single-unit recording has become one of the most powerful in vivo electro-physiological techniques for investigating neural circuits. The demand for small and lightweight chronic recording devices with large number of electrodes has been increasing. However, conventional techniques do not allow fine adjustments to be made over large number of electrodes across multiple brain regions without disturbing the recording subject. Here, we have developed a large-scale motorized microdrive array to record from freely behaving animals. It has design flexibility and allows for remote adjustment of a large number of electrodes at a very fine resolution. Versions of the microdrive array were chronically implanted on both rats (21 microdrives) and mice (7 microdrives) and relatively long term recordings were taken. In this talk, current status of the new technology and future directions will be presented.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
O’Keefe, J., Dostrovsky, J.: The hippocampus as a spatial map. Preliminary evidence from unit activity in the freely-moving rat. Brain Res. 34 (1971) 171–175.
McNaughton, B.L., O’Keefe, J., Barnes, C.A.: The stereotrode: a new technique for simultaneous isolation of several single units in the central nervous system from multiple unit records. J. Neurosci. Methods. 8 (1983) 391–397.
Wilson, M.A., McNaughton, B.L.: Dynamics of the hippocampal ensemble code for space. Science. 261 (1993) 1055–1058.
Yamamoto, J., Wilson, M.A.: Large-scale chronically implantable precision motorized microdrive array for freely behaving animals. J. Neurophysiol. 100(4) (2008) 2430–2440.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media B.V.
About this paper
Cite this paper
Yamamoto, J. (2011). Next Generation Large-Scale Chronically Implantable Precision Motorized Microdrive Arrays for Freely Behaving Animals. In: Wang, R., Gu, F. (eds) Advances in Cognitive Neurodynamics (II). Springer, Dordrecht. https://doi.org/10.1007/978-90-481-9695-1_9
Download citation
DOI: https://doi.org/10.1007/978-90-481-9695-1_9
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-9694-4
Online ISBN: 978-90-481-9695-1
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)