Skip to main content

Performance Parameters of Gamma Cameras

  • Chapter
  • First Online:

Abstract

The quality and detail of an image obtained by gamma cameras are affected by several parameters associated with these imaging systems. These parameters include spatial resolution, sensitivity, uniformity, and contrast, and they are described here in detail. A brief description of the quality control tests for gamma cameras is also included.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   79.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   99.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   139.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References and Suggested Readings

  • Bushberg JT, Seibert JA, Leidholdt EM Jr, Boone JM. The essential physics of medical imaging. 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2011.

    Google Scholar 

  • Cherry SR, Sorensen JA, Phelps ME. Physics in nuclear medicine. 3rd ed. Philadelphia: W.B. Saunders; 2003.

    Google Scholar 

  • Erickson J. Imaging systems. In: Harbert J, da Rocha AFG, ed. Textbook of nuclear medicine. Volume I. Basic science. Philadelphia: Lea & Febiger; 1984:105.

    Google Scholar 

  • Groch MW, Erwin WD. Single-photon emission computed tomography in the year 2001: Instrumentation and quality control. J Nucl Med Technol. 2001;29:12.

    PubMed  CAS  Google Scholar 

  • Murphy PH. Acceptance testing and quality control of gamma cameras, including SPECT.J Nucl Med 1987;28:1221.

    Google Scholar 

  • Rollo FD. Evaluating imaging devices. In: Rollo FD, ed. Nuclear physics, instrumentation and agents. St. Louis: Mosby; 1977:436.

    Google Scholar 

  • Rollo FD, Harris CC. Factors affecting image formation. In: Rollo FD, ed. Nuclear physics, instrumentation and agents. St. Louis: Mosby; 1977:387.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Gopal B. Saha Ph.D. .

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer Science+Business Media New York

About this chapter

Cite this chapter

Saha, G.B. (2013). Performance Parameters of Gamma Cameras. In: Physics and Radiobiology of Nuclear Medicine. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-4012-3_10

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-4012-3_10

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-4011-6

  • Online ISBN: 978-1-4614-4012-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics