Non-Invasive Measurement of Intracranial Pressure in Neonates and Infants: Experience with the Rotterdam Teletransducer

  • Conference paper
Intracranial Pressure and Neuromonitoring in Brain Injury

Part of the book series: Acta Neurochirurgica Supplements ((NEUROCHIRURGICA,volume 71))

  • 603 Accesses

Summary

On the basis of an experience of more than 400 recordings, we demonstrate the usefulness of the anterior fontanelle pressure monitoring (AFP) in several clinical conditions. Main indications for AFP monitoring are the evaluation and the differential diagnosis of neonatal encephalopathy and the assessment of infants with enlarged ventricular spaces, ventriculo-peritoneal derivation or increased head growth rate. Further technical progress is needed to permit AFP recordings in infants with small anterior fontanelle and to reduce the time necessary for the AFP measurement and interpretation procedure. We conclude that it is technically possible and clinically helpful to obtain accurate information about ICP and changes in cerebral compliance in a wide range of clinical conditions without the use of invasive techniques.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Archer LNJ, Levene MI, Evans DH (1986) Cerebral artery doppler ultrasonography for prediction of outcome after perinatal asphyxia. Lancet ii: 1116–1117

    Article  Google Scholar 

  2. de Jong DA, Maas A, van de Voort E (1984) Non-invasive intracranial pressure monitoring. A technique for reproducible fontanelle pressure measurements. Z Kinderchir 39: 274–276

    PubMed  Google Scholar 

  3. Di Rocco C, Mc Lone DG, Shimoji T, Raimondi AJ (1975) Continuous intraventricular cerebrospinal fluid pressure recording in hydrocephalic children during wakefulness and sleep. J Neurosurg 51: 206–210

    Google Scholar 

  4. Finer N, Robertson C, Richards R, Pinnell R, Peters K (1981) Hypoxic-ischemic encephalopathy in term neonates: perinatal factors and outcome. J Pediatr 98: 112–119

    Article  PubMed  CAS  Google Scholar 

  5. Hanlo PW, Gooskens RH, Van der Knaap MS, Schooneveld M, Faber JAJ, Tulleken CAF, Willemse J (1996) The effect of ICP on myelination and the relationship with neurodevelopment in infantile hydrocephalus. In: Thesis Universiteit Utrecht. Koninklijke Bibliotheek, Den Haag

    Google Scholar 

  6. Hanlo PW, Gooskens RH, Van der Meulen JHP, Braun KP, Vandertap WP, Tulleken CAF, Willemse J (1996) Noninvasive measurements of ICP in infantile hydrocephalus: the relationships between raised ICP, shunt implantation and outcome. In: Thesis Universiteit Utrecht. Koninklijke Bibliotheek, Den Haag

    Google Scholar 

  7. Levene M, Evans D, Forde A, Archer L (1987) Value of ICP monitoring of asphyxiated newborn infants. Dev Med Child Neurol 29: 311–319

    Article  PubMed  CAS  Google Scholar 

  8. Massager N, Wayenberg JL, Vermeylen D, Brotchi (1998) Anterior fontanelle pressure recordings with the Rotterdam teletransducer: variation of parameters with age in healthy infants. Acta Neurochir (Wien) [Suppl] 71: 53–55

    CAS  Google Scholar 

  9. Wayenberg JL, Raftopoulos C, Vermeylen D, Pardou A (1993) Non-invasive measurement of ICP in the newborn and the infant: the Rotterdam Teletransducer. Arch Dis Child 69: 493–497

    Article  PubMed  CAS  Google Scholar 

  10. Wayenberg JL, Hasaerts D, Franco P, Valente F, Massager N (1995) Anterior fontanelle pressure monitoring during sleep in healthy infants. Sleep 18: 223–228

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer-Verlag Wien

About this paper

Cite this paper

Wayenberg, JL. (1998). Non-Invasive Measurement of Intracranial Pressure in Neonates and Infants: Experience with the Rotterdam Teletransducer. In: Marmarou, A., et al. Intracranial Pressure and Neuromonitoring in Brain Injury. Acta Neurochirurgica Supplements, vol 71. Springer, Vienna. https://doi.org/10.1007/978-3-7091-6475-4_22

Download citation

  • DOI: https://doi.org/10.1007/978-3-7091-6475-4_22

  • Publisher Name: Springer, Vienna

  • Print ISBN: 978-3-7091-7331-2

  • Online ISBN: 978-3-7091-6475-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics