Summary
On the basis of an experience of more than 400 recordings, we demonstrate the usefulness of the anterior fontanelle pressure monitoring (AFP) in several clinical conditions. Main indications for AFP monitoring are the evaluation and the differential diagnosis of neonatal encephalopathy and the assessment of infants with enlarged ventricular spaces, ventriculo-peritoneal derivation or increased head growth rate. Further technical progress is needed to permit AFP recordings in infants with small anterior fontanelle and to reduce the time necessary for the AFP measurement and interpretation procedure. We conclude that it is technically possible and clinically helpful to obtain accurate information about ICP and changes in cerebral compliance in a wide range of clinical conditions without the use of invasive techniques.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Archer LNJ, Levene MI, Evans DH (1986) Cerebral artery doppler ultrasonography for prediction of outcome after perinatal asphyxia. Lancet ii: 1116–1117
de Jong DA, Maas A, van de Voort E (1984) Non-invasive intracranial pressure monitoring. A technique for reproducible fontanelle pressure measurements. Z Kinderchir 39: 274–276
Di Rocco C, Mc Lone DG, Shimoji T, Raimondi AJ (1975) Continuous intraventricular cerebrospinal fluid pressure recording in hydrocephalic children during wakefulness and sleep. J Neurosurg 51: 206–210
Finer N, Robertson C, Richards R, Pinnell R, Peters K (1981) Hypoxic-ischemic encephalopathy in term neonates: perinatal factors and outcome. J Pediatr 98: 112–119
Hanlo PW, Gooskens RH, Van der Knaap MS, Schooneveld M, Faber JAJ, Tulleken CAF, Willemse J (1996) The effect of ICP on myelination and the relationship with neurodevelopment in infantile hydrocephalus. In: Thesis Universiteit Utrecht. Koninklijke Bibliotheek, Den Haag
Hanlo PW, Gooskens RH, Van der Meulen JHP, Braun KP, Vandertap WP, Tulleken CAF, Willemse J (1996) Noninvasive measurements of ICP in infantile hydrocephalus: the relationships between raised ICP, shunt implantation and outcome. In: Thesis Universiteit Utrecht. Koninklijke Bibliotheek, Den Haag
Levene M, Evans D, Forde A, Archer L (1987) Value of ICP monitoring of asphyxiated newborn infants. Dev Med Child Neurol 29: 311–319
Massager N, Wayenberg JL, Vermeylen D, Brotchi (1998) Anterior fontanelle pressure recordings with the Rotterdam teletransducer: variation of parameters with age in healthy infants. Acta Neurochir (Wien) [Suppl] 71: 53–55
Wayenberg JL, Raftopoulos C, Vermeylen D, Pardou A (1993) Non-invasive measurement of ICP in the newborn and the infant: the Rotterdam Teletransducer. Arch Dis Child 69: 493–497
Wayenberg JL, Hasaerts D, Franco P, Valente F, Massager N (1995) Anterior fontanelle pressure monitoring during sleep in healthy infants. Sleep 18: 223–228
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer-Verlag Wien
About this paper
Cite this paper
Wayenberg, JL. (1998). Non-Invasive Measurement of Intracranial Pressure in Neonates and Infants: Experience with the Rotterdam Teletransducer. In: Marmarou, A., et al. Intracranial Pressure and Neuromonitoring in Brain Injury. Acta Neurochirurgica Supplements, vol 71. Springer, Vienna. https://doi.org/10.1007/978-3-7091-6475-4_22
Download citation
DOI: https://doi.org/10.1007/978-3-7091-6475-4_22
Publisher Name: Springer, Vienna
Print ISBN: 978-3-7091-7331-2
Online ISBN: 978-3-7091-6475-4
eBook Packages: Springer Book Archive