Helical 4D CT and Comparison with Cine 4D CT

  • Chapter
  • First Online:

Part of the book series: Biological and Medical Physics, Biomedical Engineering ((BIOMEDICAL))

Abstract

4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Somatom Sensation Open Reference Manual, pp. 159–177

    Google Scholar 

  2. Quick Steps for Retrospective Spiral Respiratory Correlated Imaging with Varian RPM (2007). For the Brilliance CT Big Bore v2.2.2 system and the Brilliance 16–64 v2.2.5

    Google Scholar 

  3. Coolens, C., Bracken, J., Driscoll, B., Hope, A., Jaffray, D.: Dynamic volume versus respiratory correlated 4DCT for motion assessment in radiation therapy simulation. Med. Phys. 39(5), 2669–2681 (2012)

    Article  Google Scholar 

  4. Dewey, M., Zimmermann, E., Laule, M., Rutsch, W., Hamm, B.: Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography. Eur. Heart J. 29(13), 1669 (2008)

    Article  Google Scholar 

  5. Flohr, T.G., McCollough, C.H., Bruder, H., Petersilka, M., Gruber, K., Suss, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., Primak, A.N., Kuttner, A., Achenbach, S., Becker, C., Kopp, A., Ohnesorge, B.M.: First performance evaluation of a dual-source CT (DSCT) system. Eur. Radiol. 16(2), 256–268 (2006)

    Article  Google Scholar 

  6. Flohr, T.G., Stierstorfer, K., Ulzheimer, S., Bruder, H., Primak, A.N., McCollough, C.H.: Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med. Phys. 32(8), 2536–2547 (2005)

    Article  Google Scholar 

  7. Ford, E.C., Mageras, G.S., Yorke, E., Ling, C.C.: Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med. Phys. 30(1), 88–97 (2003)

    Article  Google Scholar 

  8. Han, D., Bayouth, J., Bhatia, S., Sonka, M., Wu, X.: Characterization and identification of spatial artifacts during 4D-CT imaging. Med. Phys. 38(4), 2074–2087 (2011)

    Article  Google Scholar 

  9. Hurkmans, C.W., van Lieshout, M., Schuring, D., van Heumen, M.J., Cuijpers, J.P., Lagerwaard, F.J., Widder, J., van der Heide, U.A., Senan, S.: Quality assurance of 4D-CT scan techniques in multicenter phase III trial of surgery versus stereotactic radiotherapy (radiosurgery or surgery for operable early stage (stage 1A) non-small-cell lung cancer [ROSEL] study). Int. J. Radiat. Oncol. Biol. Phys. 80(3), 918–927 (2011)

    Article  Google Scholar 

  10. Kalender, W.A., Seissler, W., Klotz, E., Vock, P.: Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176(1), 181–183 (1990)

    Google Scholar 

  11. Keall, P.J., Starkschall, G., Shukla, H., Forster, K.M., Ortiz, V., Stevens, C.W., Vedam, S.S., George, R., Guerrero, T., Mohan, R.: Acquiring 4D thoracic CT scans using a multislice helical method. Phys. Med. Biol. 49(10), 2053–2067 (2004)

    Article  Google Scholar 

  12. Klahr, P., Subramanian, P., Yanof, J.H.: Respiratory-correlated multislice CT for radiation therapy planning: imaging and visualization methods. Medicamundi 49(3), 34–37 (2005)

    Google Scholar 

  13. Kubo, H.D., Hill, B.C.: Respiration gated radiotherapy treatment: a technical study. Phys. Med. Biol. 41(1), 83–91 (1996)

    Article  Google Scholar 

  14. Li, X.A., Stepaniak, C., Gore, E.: Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system. Med. Phys. 33(1), 145–154 (2006)

    Article  Google Scholar 

  15. Low, D.A., Nystrom, M., Kalinin, E., Parikh, P., Dempsey, J.F., Bradley, J.D., Mutic, S., Wahab, S.H., Islam, T., Christensen, G., Politte, D.G., Whiting, B.R.: A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med. Phys. 30(6), 1254–1263 (2003)

    Article  Google Scholar 

  16. Pan, T.: Comparison of helical and cine acquisitions for 4D-CT imaging with multislice CT. Med. Phys. 32(2), 627–634 (2005)

    Article  Google Scholar 

  17. Pan, T., Lee, T.Y., Rietzel, E., Chen, G.T.: 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. Med. Phys. 31(2), 333–340 (2004)

    Article  Google Scholar 

  18. Parker, D.L.: Optimal short scan convolution reconstruction for fanbeam CT. Med. Phys. 9(2), 254–257 (1982)

    Article  Google Scholar 

  19. Siebert, E., Bohner, G., Dewey, M., Masuhr, F., Hoffmann, K.T., Mews, J., Engelken, F., Bauknecht, H.C., Diekmann, S., Klingebiel, R.: 320-slice CT neuroimaging: initial clinical experience and image quality evaluation. Br. J. Radiol. 82(979), 561–570 (2009)

    Article  Google Scholar 

  20. Vedam, S.S., Keall, P.J., Kini, V.R., Mostafavi, H., Shukla, H.P., Mohan, R.: Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys. Med. Biol. 48(1), 45–62 (2003)

    Article  Google Scholar 

  21. Zamora, D.A., Riegel, A.C., Sun, X., Balter, P., Starkschall, G., Mawlawi, O., Pan, T.: Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning. Med. Phys. 37(11), 5811–5820 (2010)

    Article  Google Scholar 

Download references

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tinsu Pan .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Pan, T. (2013). Helical 4D CT and Comparison with Cine 4D CT. In: Ehrhardt, J., Lorenz, C. (eds) 4D Modeling and Estimation of Respiratory Motion for Radiation Therapy. Biological and Medical Physics, Biomedical Engineering. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-36441-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-36441-9_2

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-36440-2

  • Online ISBN: 978-3-642-36441-9

  • eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)

Publish with us

Policies and ethics