Abstract
Monoblock acetabular cups represent a subtype of uncemented cups with the polyethylene liner molded into a metal shell, thus eliminating or at least minimizing potential backside wear. We hypothesized that the use of monoblock cups could reduce the incidence of osteolysis and aseptic loosening, and thus improve survival compared with modular designs.
All 210 primary total hip arthroplasty (THA) procedures in the Swedish Hip Arthroplasty Register using uncemented monoblock cups during 1999-2010 were identified. Kaplan-Meier and Cox-regression analysis with adjustment for age, sex, and other variables were used to calculate survival rates and adjusted hazard ratios (HR) of the revision risk for any reason. 1,130 modular cups, inserted during the same time period were used as a control group.
There was a nearly equal sex distribution in both groups. The median age at index operation was 47 years in the monoblock group and 56 years in the control group (p<0.001). The cumulative 5-year survival with any revision as the endpoint was 95% (95% CI 91-98) for monoblock cups and 97% (CI 96-98) for modular cups (p=0.6). The adjusted HR of monoblock cups for revision compared with modular cups was 2 (CI 0.8-6; p=0.1). The use of 28 mm prosthesis heads compared with 22 mm heads decreased the risk of cup revision (HR 0.2, CI 0.1-0.5; p=0.001).
Both cups showed good mid-term survival rates. There was no statistically significant difference in revision risk between the cup designs. Further review of the current patient population is warranted to determine the long-term durability and risk of revision of monoblock cup designs.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ali MS, Kumar A (2003) Hydroxyapatite-coated RM cup in primary hip arthroplasty. Int Orthop 27:90–93
AOA. Australian Orthopaedic Association National Joint Replacement Registry annual report 2009. http://www.dmac.adelaide.edu.au/aoanjrr/publications.jsp
Baad-Hansen T, Kold S, Nielsen PT, Laursen MB, Christensen PH, Soballe K (2011) Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips. Acta Orthop 82:155–160
Berli BJ, Ping G, Dick W, Morscher EW (2007) Nonmodular flexible press-fit cup in primary total hip arthroplasty: 15-year followup. Clin Orthop Relat Res 461:114–121
Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau M (2007) Minimum 6-year followup of highly cross-linked polyethylene in THA. Clin Orthop Relat Res 465:122–127
Bystrom S, Espehaug B, Furnes O, Havelin LI (2003) Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register. Acta Orthop Scand 74:514–524
Conroy JL, Whitehouse SL, Graves SE, Pratt NL, Ryan P, Crawford RW (2008) Risk factors for revision for early dislocation in total hip arthroplasty. J Arthroplasty 23:867–872
Dorr LD, Wan Z, Shahrdar C, Sirianni L, Boutary M, Yun A (2005) Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg Am 87:1816–1821
Garavaglia G, Lubbeke A, Barea C, Roussos C, Peter R, Hoffmeyer P (2011) Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws. Int Orthop 35:957–963
González Della Valle A, Su E, Zoppi A, Sculco TP, Salvati EA (2004) Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups. J Arthroplasty 19:972–977
Gwynne-Jones DP, Garneti N, Wainwright C, Matheson JA, King R (2009) The Morscher Press Fit acetabular component: a nine- to 13-year review. J Bone Joint Surg Br 91:859–864
Hailer NP, Garellick G, Karrholm J (2010) Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register. Acta Orthop 81:34–41
Ihle M, Mai S, Pfluger D, Siebert W (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg Br 90:1284–1290
Kostakos AT, Macheras GA, Frangakis CE, Stafilas KS, Baltas D, Xenakis TA (2010 Jan) Migration of the trabecular metal monoblock acetabular cup system. J Arthroplasty 25(1):35–40
Lazarinis S, Karrholm J, Hailer NP (2010) Increased risk of revision of acetabular cups coated with hydroxyapatite. Acta Orthop 81:53–59
Lie SA, Engesaeter LB, Havelin LI, Gjessing HK, Vollset SE (2004) Dependency issues in survival analyses of 55,782 primary hip replacements from 47,355 patients. Stat Med 23:3227–3240
Macheras G, Kateros K, Kostakos A, Koutsostathis S, Danomaras D, Papagelopoulos PJ (2009) Eight- to ten-year clinical and radiographic outcome of a porous tantalum monoblock acetabular component. J Arthroplasty 24:705–709
Malizos KN, Bargiotas K, Papatheodorou L, Hantes M, Karachalios T (2008) Survivorship of monoblock trabecular metal cups in primary THA: midterm results. Clin Orthop Relat Res 466:159–166
Meneghini RM, Ford KS, McCollough CH, Hanssen AD, Lewallen DG (2010) Bone remodeling around porous metal cementless acetabular components. J Arthroplasty 25:741–747
Morscher E, Masar Z (1988) Development and first experience with an uncemented press-fit cup. Clin Orthop Relat Res 1988:96–103
Morscher E, Berli B, Jockers W, Schenk R (1997) Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures. Clin Orthop Relat Res 341:42–50
National Joint Registry (NJR) of England and Wales (2010) Seventh annual report (April 2009–March 2010). http://www.njrcentre.org.uk
Ranstam J, Karrholm J, Pulkkinen P, Makela K, Espehaug B, Pedersen AB, Mehnert F, Furnes O (2011) Statistical analysis of arthroplasty data. II. Guidelines. Acta Orthop 82:258–267
Sculco TP (2002) The acetabular component: an elliptical monoblock alternative. J Arthroplasty 17:118–120
Swedish Hip Arthroplasty Register (2010) Annual report 2010. http://www.jru.orthop.gu.se
Weiss RJ, Hailer NP, Stark A, Kärrholm J (2012 Jun) Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register. Acta Orthop 83(3):214–219
Young AM, Sychterz CJ, Hopper RH Jr, Engh CA (2002) Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84-A:58–63
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 EFORT
About this chapter
Cite this chapter
Weiss, R.J., Kärrholm, J., Stark, A., Hailer, N.P. (2013). Survival of Monoblock Acetabular Cups Versus an Uncemented Modular Cup Design: A Population-Based Study from the Swedish Hip Arthroplasty Register. In: Knahr, K. (eds) Total Hip Arthroplasty. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-35653-7_20
Download citation
DOI: https://doi.org/10.1007/978-3-642-35653-7_20
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-35652-0
Online ISBN: 978-3-642-35653-7
eBook Packages: MedicineMedicine (R0)