Abstract
Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologist may determine the cup and disc areas and diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. The edge of optic disc was then detected by use of a canny edge detection filter. The profile was then obtained around the center of the optic disc in the vertical direction. Subsequently, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Iwase, A., Suzuki, Y., Araie, M., Yamamoto, T., Abe, H., Shirato, S., Kuwayama, Y., Mishima, H., Shimizu, H., Tomita, G.: The prevalence of primary open-angle glaucoma in Japanese: The Tajimi study. Ophthalmology 111, 1641–1648 (2004)
Yamamoto, T., Iwase, A., Araie, M., Suzuki, Y., Abe, H., Shirato, S., Kuwayama, Y., Mishima, H., Shimizu, H., Tomita, G.: The Tajimi study report 2 prevalence of primary angle closure and secondary glaucoma in a Japanese population. Ophthalmology 112, 1661–1669 (2005)
Quigley, H., Broman, A.: The number of people with glaucoma worldwide in 2010 and 2020. British J. Ophthalmology 90, 262–267 (2006)
Hatanaka, Y., Hara, T., Fujita, H., Aoyama, M., Uchida, H., Yamamoto, Y.: Automatic distribution and shape analysis of blood vessels on retinal images. In: Proc. SPIE, vol. 5370, pp. 1621–1628. SPIE, Bellingham (2004)
Takahashi, R., Hatanaka, Y., Nakagawa, T., Hayashi, Y., Aoyama, A., Mizukusa, Y., Fujita, A., Kakogawa, M., Hara, T., Fujita, H.: Automated analysis of blood vessel intersections in retinal images for diagnosis of hypertension. Medical Imaging Technology 24, 270–276 (2006)
Hayashi, T., Nakagawa, T., Hatanaka, Y., Hayashi, Y., Aoyama, A., Mizukusa, Y., Fujita, A., Kakogawa, M., Hara, T., Fujita, H.: An artery-vein classification using top-hat image and detection of arteriolar narrowing on retinal images. IEICE Technical Report, vol. 107, pp. 127—132. IEICE, Tokyo (2007)
Hatanaka, Y., Nakagawa, T., Hayashi, Y., Fujita, A., Kakogawa, M., Kawase, K., Hara, T., Fujita, H.: CAD scheme to detect hemorrhages and exudates in ocular fundus images. In: Proc. SPIE, vol. 6514, pp. 65142M-1–65142M-8 (2007)
Hatanaka, Y., Nakagawa, T., Hayashi, Y., Kakogawa, M., Sawada, A., Kawase, K., Hara, T., Fujita, H.: Improvement of automatic hemorrhages detection methods using brightness correction on fundus images. In: Proc. SPIE, vol. 6915, pp. 69153E-1–69153E-10. SPIE, Bellingham (2008)
Mizutani, A., Muramatsu, C., Hatanaka, Y., Suemori, S., Hara, T., Fujita, H.: Automated microaneurysms detection method based on double ring filter in retinal fundus images. In: Proc. SPIE, vol. 7260, pp. 72601N-1–72601N-8. SPIE, Bellingham (2009)
Muramatsu, C., Hayashi, Y., Sawada, A., Hatanaka, Y., Yamamoto, T., Fujita, H.: Detection of retinal nerve fiber layer defects on retinal fundus images for early diagnosis of glaucoma. J. Biomedical Optics 15, 016021-1–7 (2010)
Nakagawa, T., Hayashi, Y., Hatanaka, Y., Aoyama, A., Mizukusa, Y., Fujita, A., Kakogawa, M., Hara, T., Fujita, H., Yamamoto, T.: Recognition of optic nerve head using blood-vessel-erased image and its application to production of simulated stereogram in computer-aided diagnosis system for retinal images. IEICE Transactions on Information and Systems J89-D, 2491–2501 (2006)
Nakagawa, T., Suzuki, T., Hayashi, Y., Mizukusa, Y., Hatanaka, Y., Ishida, K., Hara, T., Fujita, H., Yamamoto, T.: Quantitative depth analysis of optic nerve head using stereo retinal fundus image pair. J. Biomedical Optics 13, 064026-1-10 (2008)
Muramatsu, C., Nakagawa, T., Sawada, A., Hatanaka, Y., Hara, T., Yamamoto, T., Fujita, H.: Determination of cup and disc ratio of optical nerve head for diagnosis of glaucoma on stereo retinal fundus image pairs. In: Proc. SPIE, vol. 7260, pp. 72603L-1–72603L-8. SPIE, Bellingham (2009)
Lalonde, M., Beaulieu, M., Gagnon, L.: Fast and robust optic disc detection using pyramidal decomposition and Hausdorff-based template matching. IEEE Transactions on Medical Imaging 20, 1193–1200 (2001)
Li, H., Chutatape, O.: Automated feature extraction in color retinal images by a model based approach. IEEE Transactions on Biomed. Engineering 51, 246–254 (2004)
Chrastek, R., Wolf, M., Donath, K., Niemann, H., Paulus, D., Hothorn, T., Lausen, B., Lammer, R., Mardin, C.Y., Michelson, G.: Automated segmentation of the optic nerve head for diagnosis of glaucoma. Medical Image Analysis 9, 297–314 (2005)
Merickel, M.B., Wu, X., Sonka, M., Abramoff, M.D.: Optimal segmentation of the optic nerve head from stereo retinal images. In: Proc. SPIE, vol. 6143, pp. 61433B-1–61433B-8. SPIE, Bellingham (2006)
Xu, J., Ishikawa, H., Wollstein, G., Bilonick, R.A., Sung, K.R., Kagemann, L., Townsend, K.A., Schuman, J.S.: Automated assessment of the optic nerve head on stereo disc photographs. Investigative Ophthalmology & Visual Science 49, 2512–2517 (2008)
Abramoff, M.D., Alward, W.L.M., Greenlee, E.C., Shuba, L., Kim, C.Y., Fingert, J.H., Kwon, Y.H.: Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features. Investigative Ophthalmology & Visual Science 48, 1665–1673 (2007)
Corona, E., Mitra, S., Wilson, M., Krile, T., Kwon, Y.H., Soliz, P.: Digital stereo image analyzer for generating automated 3-D measures of optic disc deformatin in glaucoma. IEEE Transactions on Medical Imaging 21, 1244–1253 (2002)
Mikelberg, F.S., Parfitt, C.M., Swindale, N.V., Graham, S.L., Drance, S.M., Gosine, R.: Ability of the Heidelberg Retina Tomograph to detect early glaucomatous visual field loss. J. Glaucoma 4, 242–247 (1995)
Wong, D.W.K., Liu, J., Lim, J.H., Li, H., Wong, T.Y.: Automated detection of kinks from blood vessels for optic cup segmentation in retinal images. In: Proc. SPIE, vol. 7260, pp. 72601J-1–72601J-8. SPIE, Bellingham (2009)
Parker, J.R.: Algorithms for image processing and computer vision. Wiley Computer Publishing, New York (1997)
Canny, J.: A computational approach to edge detection. IEEE Transactions on Pattern Analysis and Machine Intelligence 8, 679–698 (1986)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Hatanaka, Y. et al. (2010). Automatic Measurement of Vertical Cup-to-Disc Ratio on Retinal Fundus Images. In: Zhang, D., Sonka, M. (eds) Medical Biometrics. ICMB 2010. Lecture Notes in Computer Science, vol 6165. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-13923-9_7
Download citation
DOI: https://doi.org/10.1007/978-3-642-13923-9_7
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-13922-2
Online ISBN: 978-3-642-13923-9
eBook Packages: Computer ScienceComputer Science (R0)