Abstract
Several factors in noninvasive positive pressure ventilation (NIPPV) have proved to be potential causes of failure when this kind of mechanical respiratory assistance is used in patients who suffer from acute (ARF) or chronic (CRF) respiratory failure [1–3]. One such factor is carbon dioxide (CO2) rebreathing [1–4]. This phenomenon consists of rebreathing part of the CO2 expired by the patient during the ventilatory cycle as a result of an accumulation of this gas in the mask or the circuit. Such rebreathing takes place mainly in single-limb circuits (inspiration and expiration into the same tube). Besides the use of such a circuit, there are technical circumstances that play an active role in the presence or elimination of expired CO2: the ventilatory mode [4, 5], type of mask and expiratory port [6–12], as well as the level of positive end-expiratory pressure (PEEP) used [4, 10, 11]. Since 1995, when Ferguson and his collaborators first described such a phenomenon, little research has been done on this issue. The development of technological innovations, mainly in interfaces, has restricted the potential clinical implications of this deleterious phenomenon. Likewise, research works conducted so far have not confirmed whether CO2 rebreathing does have a significant influence on patients’ clinical evolution or is just a potentially, but rarely, harmful phenomenon.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Hill NS (2001) Problems, remedies, and strategies to optimize the success of noninvasive ventilation. In: Hill NS (ed) Non invasive positive pressure ventilation. Futura, Armonk, NY, pp 187–213
Kacmarek RM, Hill N (2001) Ventilators for NIPPV: technical aspects. Eur Resp Mon 16:76–105
Frades SH, Peces Barba G (2007) In: Lucas Ramos P, Jareño Esteban JJ (eds) Ventilacion mecanica no invasiva: ineficacia y complicaciones. Monografias de la Sociedad Madrileña de Neumologia y Cirugia toracica (NeumoMadrid), volumen IX: Ventilacion no invasiva. Madrid, pp 45–61
Ferguson GT, Gilmartin M (1995) CO2 rebreathing during BiPAP ventilatory assistance. Am J Respir Crit Care Med 151:1126–1135
Lofaso F, Brochard L, Touchard D, Hang T, Harf A, Isabey D (1995) Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices. Chest 108:772–778
Zhang X, Chen R, He G (2000) Modification of facial mask on the dead space effect in non invasive mask ventilation. Zhonghua Jie He He Hu Xi Za Zhi 23(12):734–736
Schettino GP, Chatmongkolchart S, Hess DR, Kacmarek R (2003) Position of exhalation port and mask design affect CO2 rebreathing during non-invasive positive pressure ventilation. Crit Care Med 31(8):2178–2182
Taccone P, Hess D, Caironi P, Bigatello LM (2004) Continuous positive airway pressure delivered with a helmet. Effects on carbon dioxide rebreathing. Crit Care Med 32(10):2090–2096
Racca F, Appendini L, Gregoretti C (2005) Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in human model of resistive breathing. J Appl Physiol 99:1262–1271
Mediano O, Garcia Rio F, Villasante C (2006) Comparacion de la reinhalación de anhídrido carbónico originada por 3 mascarillas durante la aplicacion de CPAP. Arch Bronconeumol 42(4):189–193
Samolski D, Calaf N, Guell R, Casan P, Anton A (2008) Carbon dioxide rebreathing in non-invasive ventilation. Analysis of masks, expiratory ports and ventilatory modes. Monaldi Arch Chest Dis 69(3):114–118
Racca F, Appendini L, Gregoretti C et al (2008) Helmet ventilation and carbon dioxide rebreathing: effects of adding a leak at the helmet ports. Intensive Care Med 34:1461–1468
Saatci E, Miller DM, Stell IM, Lee KC, Moxham J (2004) Dynamic dead space in face masks used with non-invasive ventilators: a lung model study. Eur Respir J 23:129–135
Samolski D, Guell R, Calaf N et al. (2006) Analysis of CO2 rebreathing in hypercapnic patients while using different expiratory devices in non-invasive ventilation. Eur Resp J 28(S50)
Hill NS, Carlisle C, Kramer N (2002) Effect of a nonrebreathing exhalation valve on long term nasal ventilation using a bilevel device. Chest 122:84–91
Farre R, Montserrat JM, Ballester E, Navajas D (2002) Potential rebreathing after CPAP failure during sleep. Chest 121(1):196–200
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Samolski, D., Antón, A. (2010). Carbon Dioxide Rebreathing in Noninvasive Ventilation. In: Esquinas, A. (eds) Noninvasive Mechanical Ventilation. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-11365-9_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-11365-9_14
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-11364-2
Online ISBN: 978-3-642-11365-9
eBook Packages: MedicineMedicine (R0)