Abstract
In the article methods for verifying the dimensional and material properties like GS, GF i GG on industrial CT scanners according to VDI/VDE 2630 Blatt 1.3. “Computertomografie in der dimensionellen Messtechnik” guidelines were described. The proposed gauges in the form of a stepped cylinder were presented. In studies two types of different materials of gauges with different X-ray absorption coefficients were used. The study on METROTOM CT 800 manufactured by C. Zeiss with the X-ray tube voltage of 130 kV was performed. As the material for the gauges aluminum (aluminum alloy PA6) and ertacetal was selected. Both gauges in an accredited laboratory were calibrated.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
De Chiffre, L., Carmignato, S., Kruth, J.P., Schmitt, R., Weckenmann, A.: Industrial applications of computed tomography. CIRP Annals - Manufacturing Technology. 63 (2014) 655–677
Kruth, J.P., Bartscher, M., Carmignato, S., Schmitt, R., De Chiffre, L., Weckenmann A.: Computed tomography for dimensional metrology. CIRP Annals - Manufacturing Technology. 60 (2011), pp. 821–842
Müller P., Hiller J., Cantatore A., Tosello G., De Chiffre L.: „New reference object for metrological performance testing of industrial CT systems”. Departement of Mechanical Engineering, Technical University of Denmark (DTU), Kgs. Lyngby (Dania), 2012
Ryniewicz A.: „Accuracy assessment of shape mapping using Computer Tomography”. Metrology and Measuring Systems. Quarterly of Polish Academy of Sciences. Vol.XVII, No.3/2010.482-491
VDI/VDE 2617 Blatt 13: Accuracy of coordinate measuring machines - Characteristics and their testing - Guideline for the application of DIN EN ISO 10360 for coordinate measuring machines with CT-sensors.
Acknowledgements
The research described in the article have been financed with funds from the National Research and Development Centre. Grant NCBiR no. PBS2/B6/16/2013.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this paper
Cite this paper
Kowaluk, T., Woźniak, A. (2016). Methods for verifying the dimensional and material properties on industrial CT scanners according to VDI / VDE 2630 Blatt 1.3.. In: Jabłoński, R., Brezina, T. (eds) Advanced Mechatronics Solutions. Advances in Intelligent Systems and Computing, vol 393. Springer, Cham. https://doi.org/10.1007/978-3-319-23923-1_52
Download citation
DOI: https://doi.org/10.1007/978-3-319-23923-1_52
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-23921-7
Online ISBN: 978-3-319-23923-1
eBook Packages: EngineeringEngineering (R0)