Abstract
The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance.
To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
International Electrotechnical Commission. Medical electrical equipment—characteristics of digital X-ray imaging devices. Part 1: Determination of the detective quantum efficiency. In: International Standard IEC62220-1, Geneva; 2003.
Samei E. Performance of digital radiographic detectors: quantification and assessment methods. In: Samei E, Flynn MJ, editors. Syllabus: advances in digital radiography—categorical course in diagnostic radiology physics. Oak Brook, IL: Radiological Society of North America; 2003. p. 37–47.
Dobbins JT. Image quality metrics for digital systems. In: Beutel J, Kundel H, Van Metter RL, editors. Handbook of medical imaging. Washington, DC: SPIE Press; 2003.
Samei E, Buhr E, Granfors P, Vandenbroucke D, Wang X. Comparison of edge analysis techniques for the determination of the MTF of digital radiographic systems. Phys Med Biol. 2005;50:3613–25.
Lawinsky C, Mackenzie A, Cole H, Blake P, Honey I. Digital detectors for general radiography. A comparative report. In: KCARE. Centre for Evidence-based Purchase. Available at www.pasa.nhs.uk (2005).
Doyle P. Assessment and optimization of digital radiography systems for clinical use [doctoral dissertation]. Glasgow: Department of Clinical Physics, Glasgow University; 2009.
Mackenzie A, Honey I, Emerton D, Blake P, Cole H, Lawinsky C. Computed radiography systems for general radiography. In: KCARE. Centre for Evidence-based Purchase. Available at: www.pasa.nhs.uk (2006).
Rampado O, Isoardi P, Ropolo R. Quantitative assessment of computed radiography quality control parameters. Phys Med Biol. 2006;51:1577–93.
Samei E. Performance of digital radiographic detectors: factors affecting sharpness and noise. In: Samei E, Flynn MJ, editors. Syllabus: advances in digital radiography-categorical course in diagnostic radiology physics. Oak Brook, IL: Radiological Society of North America; 2003. p. 49–61.
Rowlands JA, Ji WG, Zhao W, Lee DL. Direct conversion flat panel X-ray imaging: reduction of noise by presampling filtration. Proc SPIE. 2000;3977:446–55.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media New York
About this chapter
Cite this chapter
Lança, L., Silva, A. (2013). Digital Radiography Detector Performance. In: Digital Imaging Systems for Plain Radiography. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-5067-2_3
Download citation
DOI: https://doi.org/10.1007/978-1-4614-5067-2_3
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-5066-5
Online ISBN: 978-1-4614-5067-2