Abstract
MR examinations (Achieva 3 T, Philips, Best, The Netherlands) were performed at five different occasions in a healthy volunteer (male 60 years) and in one renal cancer patient (male 78 years) with normal renal function (creatinine 88 μmol/L). Intravoxel incoherent motion (IVIM) coefficients D + D* were measured using respiratory-triggered diffusion-weighted spin-echo echo-planar imaging. Perfusion data of the patient were acquired using a saturation-recovery gradient-echo sequence and with the bolus of Gd-BOPTA (Multihance). D + D* were computed by monoexponential fitting of MR signal intensity attenuation versus b for b = 0, 50, 100, 150 s/mm2. Perfusion parameters were evaluated with “NordicICE” software. The map of D + D* was compared qualitatively with the perfusion map computed from the Gd scan. D + D* values of the cortex and medulla were in the range 2.3–2.7 and 1.1–1.6 × 10-3 mm2/s, respectively. In conclusion, in this pilot study a good qualitative relation between IVIM variables D + D* and renal perfusion has been found.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Le Bihan D et al (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168(2):497–505
Thoeny HC et al (2005) Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. Radiology 235(3):911–917
Michaely HJ et al (2008) Temporal constraints in renal perfusion imaging with a 2-compartment model. Invest Radiol 43(2):120–128
NordicNeuroLab, NordicICE, NordicNeuroLab AS (2011). Bergen, Norway
Pickens DR III et al (1992) Magnetic resonance perfusion/diffusion imaging of the excised dog kidney. Invest Radiol 27(4):287–292
Muller MF, Prasad PV, Edelman RR (1998) Can the IVIM model be used for renal perfusion imaging? Eur J Radiol 26(3):297–303
Wirestam R et al (2001) Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique. Acta Radiol 42(2):123–128
Yamada I et al (1999) Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 210(3):617–623
Acknowledgments
The work was supported by the Swedish Society for Medical Research, the Swedish Diabetes Foundation, and the Swedish Research Council.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media New York
About this paper
Cite this paper
Eckerbom, P., Hansell, P., Bjerner, T., Palm, F., Weis, J., Liss, P. (2013). Intravoxel Incoherent Motion MR Imaging of the Kidney: Pilot Study. In: Welch, W.J., Palm, F., Bruley, D.F., Harrison, D.K. (eds) Oxygen Transport to Tissue XXXIV. Advances in Experimental Medicine and Biology, vol 765. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-4989-8_8
Download citation
DOI: https://doi.org/10.1007/978-1-4614-4989-8_8
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-4771-9
Online ISBN: 978-1-4614-4989-8
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)