Abstract
Since the late 1980 s, essentially all Fontan operations at Children’s Hospital Boston have been done using a fenestrated technique. The rationale behind this modification is as follows: For a Fontan circulation to function properly, it is critical that the pulmonary vascular resistance be low and that the mean PA pressures also be low. In particular, it is desirable to have a mean PA pressure below 20 mmHg. Cardiopulmonary bypass invariably results in an increase in PVR in the immediate postoperative period. To increase cardiac output and possibly reduce the pressure in the Fontan pathway, a small hole is created in the Gore-Tex baffle that makes up part of the lateral tunnel. This fenestration is 4 mm in diameter and is directed anteriorly and leftward. It allows some of the systemic venous return to enter the systemic circulation (right-to-left shunt across the baffle) and bypass the lungs. This results in maintenance of forward cardiac output at the expense of oxygen saturation. The fenestration technique has resulted in a much more stable postoperative ICU course as well as a decreased incidence and duration of pleural effusion following Fontan surgery (1).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bridges ND. Fenestration of the Fontan baffle: Benefits and complications. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 1998;1:9–14.
Bridges ND, Lock JE, Mayer JE, Jr., Burnett J et al. Cardiac catheterization and test occlusion of the interatrial communication after the fenestrated Fontan operation. J Amer Coll Cardiol. 1995;25:1712–1717.
Bridges ND, Lock JE, Castaneda AR. Baffle fenestration with subsequent transcatheter closure. Modification of the Fontan operation for patients at increased risk. Circulation. 1990;82:1681–1689.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer Science+Business Media, LLC
About this chapter
Cite this chapter
Bergersen, L., Foerster, S., Marshall, A.C., Meadows, J. (2009). Device Closure of Fontan Fenestrations. In: Bergersen, L., Foerster, S., Marshall, A.C., Meadows, J. (eds) Congenital Heart Disease. Springer, Boston, MA. https://doi.org/10.1007/978-0-387-77292-9_16
Download citation
DOI: https://doi.org/10.1007/978-0-387-77292-9_16
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-387-77291-2
Online ISBN: 978-0-387-77292-9
eBook Packages: MedicineMedicine (R0)