Abstract

To date, the only way to directly measure intraocular pressure (IOP) is by manometry. The true pressure inside the eye cannot be determined by pressing on the outside of the eye (tonometry). At present, there are two problems with our current clinical methods of measuring IOP: namely, the lack of true accuracy and the inability to detect variations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 219.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Leske MC. The epidemiology of open-angle glaucoma: a review. Am J Epidemiol. 1983;118:166–191.

    CAS  PubMed  Google Scholar 

  2. Sommer A. Intraocular pressure and glaucoma. Am J Ophthalmol. 1989;107:186–188.

    CAS  PubMed  Google Scholar 

  3. Collaborative Normal-Tension Glaucoma Study Group. Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressures. Am J Ophthalmol. 1998;126(6):487–497.

    Google Scholar 

  4. Goldmann H, Schmidt TH. Über applanations tonometrie. Ophthalmologica. 1957;134:221–242.

    Article  CAS  PubMed  Google Scholar 

  5. Moses RA, Tarkkanen A. Tonometry: the pressure-volume relationship in the intact human eye at low pressures. Am J Ophthalmol. 1937;20:985.

    Google Scholar 

  6. Moses RA. The Goldmann applanation tonometer. Am J Ophthalmol. 1958;46:865.

    CAS  PubMed  Google Scholar 

  7. Grolman B. A new tonometer system. Am J Optom Arch Am Acad Optom. 1972;49:646.

    CAS  PubMed  Google Scholar 

  8. Detry-Morel M, Jamart J, Detry MB, et al. Clinical evaluation of the Pascal dynamic contour tonometer. J Fr Ophthalmol. 2007;20:260–270.

    Article  Google Scholar 

  9. Montard R, Kopito R, Touzeau O, et al. Ocular response analyzer: feasibility study and correlation with normal eyes. J Fr Ophthalmol. 2007;30:978–984.

    Article  CAS  Google Scholar 

  10. Brusini P, Salvetat M, Zeppieri M, et al. Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients. J Glaucoma. 2006;15:213–217.

    Article  PubMed  Google Scholar 

  11. Nouri-Mahdavi K, Hoffman D, Coleman AL, et al. Predictive factors for glaucomatous visual field progression in the Advanced Glaucoma Intervention Study. Ophthalmology. 2004;111:1627–1635.

    Article  PubMed  Google Scholar 

  12. Caprioli J. Intraocular pressure fluctuation: an independent risk factor for glaucoma? Arch Ophthalmol. 2007;125:1124–1125.

    Article  PubMed  Google Scholar 

  13. Asrani S, Zeimer R, Wilensky J, Gieser D, Vitale S, Lindenmuth K. Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J Glaucoma. 2000;9(2):134–142.

    CAS  PubMed  Google Scholar 

  14. Mosaed S, Liu J, Weinreb RN. Correlation between office and peak nocturnal intraocular pressures in healthy subjects and glaucoma patients. Am J Ophthalmol. 2005;139(2):320–324.

    Article  PubMed  Google Scholar 

  15. Wilensky JT, Gandhi N, Pan T. Racial influences in open-angle glaucoma. Ann Ophthalmol. 1978;10:1398.

    CAS  PubMed  Google Scholar 

  16. David R, Livingston D, Luntz MH. Ocular hypertension: a comparative follow-up of Black and White patients. Br J Ophthalmol. 1978;62:676.

    Article  CAS  PubMed  Google Scholar 

  17. Armaly MF. The genetic determination of ocular pressure in the normal eye. Arch Ophthalmol. 1967;78:187.

    CAS  PubMed  Google Scholar 

  18. Armaly MF, Monstavicius BF, Sayegh RE. Ocular pressure and aqueous outflow facility in siblings. Arch Ophthalmol. 1968;80:354.

    CAS  PubMed  Google Scholar 

  19. Armaly MF. On the distribution of applanation pressure. I. Statistical features and the effect of age, sex, and family history of glaucoma. Arch Ophthalmol. 1965;73:11.

    CAS  PubMed  Google Scholar 

  20. Ruprecht KW, Wulle KG, Christl HL. Applanation tonometry within medical diagnostic “check-up” programs. Klin Monatsbl Augenheilkd. 1976;169:754.

    Google Scholar 

  21. Carel RS, Korczyn AD, Rock M, Goya I. Association between ocular pressure and certain health parameters. Ophthalmology. 1984;91:311.

    CAS  PubMed  Google Scholar 

  22. Shoise Y, Kawase Y. A new approach to stratified normal intraocular pressure in a general population. Am J Ophthalmol. 1986;101:714.

    Google Scholar 

  23. Schulzer M, Drance SM. Intraocular pressure, systemic blood pressure, and age: a correlation study. Br J Ophthalmol. 1987;71:245.

    Article  CAS  PubMed  Google Scholar 

  24. Shoise Y. The aging effect on intraocular pressure in an apparently normal population. Arch Ophthalmol. 1984;102:883.

    Google Scholar 

  25. Sidler-Huguenin A. Die Spaterfolge der Glaukombehandlung bei 76 Privatpatienten von Prof Haab. Beitr Z Augenheilkd. 1898;32:1.

    Google Scholar 

  26. Katavisto M. The diurnal variations of ocular tension in glaucoma. Acta Ophthalmol Suppl. 1964;78:1–130.

    Google Scholar 

  27. Kitazawa Y, Horie T. Diurnal variation of intraocular pressure in primary open-angle glaucoma. Am J Ophthalmol. 1975;79:557.

    CAS  PubMed  Google Scholar 

  28. Newell FW, Krill AE. Diurnal tonography in normal and glaucomateous eyes. Trans Am Ophthalmol Soc. 1964;62:349.

    CAS  PubMed  Google Scholar 

  29. Wilensky JT, Gieser DK, Mori MT, et al. Self-tonometry to manage patients with glaucoma and apparently controlled intraocular pressure. Arch Ophthalmol. 1987;105:1072.

    CAS  PubMed  Google Scholar 

  30. Zeimer R. Circadian variations in intraocular pressure. In: Ritch R, Shields MB, Krupin T, eds. The Glaucomas. St Louis: C.V. Mosby; 1989.

    Google Scholar 

  31. Wilensky JT. Diurnal variations in intraocular pressure. Trans Am Ophthalmol Soc. 1991;89:757–790.

    CAS  PubMed  Google Scholar 

  32. Noel C, Kabo AM, Romanet JP, Montmayeur A, Buguet A. Twenty-four-hour time course of intraocular pressure in healthy and glaucomatous Africans: relation to sleep patterns. Ophthalmology. 2001;108(1):139–144.

    Article  CAS  PubMed  Google Scholar 

  33. Zeimer RC, Wilensky JT, Gieser DK. Presence and rapid decline of early morning intraocular pressure peaks in glaucoma patients. Ophthalmology. 1990;97(5):547–550.

    CAS  PubMed  Google Scholar 

  34. Drance SM. The significance of the diurnal tension variations in normal and glaucomateous eyes. Arch Ophthalmol. 1960;64:494.

    CAS  PubMed  Google Scholar 

  35. Drance SM. Diurnal variation of intraocular pressure in treated glaucoma: significance in patients with chronic simple glaucoma. Arch Ophthalmol. 1963;70:302.

    CAS  PubMed  Google Scholar 

  36. Starrels ME. The measurement of intraocular pressure. Int Ophthalmol Clin. 1979;19:9.

    Article  CAS  PubMed  Google Scholar 

  37. Kass MA, Gordon MO, Hoff MR, et al. Topical timolol administration reduces the incidence of glaucomatous damage in ocular hypertensive individuals: a randomized, double-masked, long-term clinical trial. Arch Ophthalmol. 1989;107:1590–1598.

    CAS  PubMed  Google Scholar 

  38. Epstein DL, Krug JH, Hertzmark E, et al. A long-term clinical trial of timolol therapy versus no treatment in management of glaucoma suspects. Ophthalmalogy. 1989;96:1460–1467.

    CAS  Google Scholar 

  39. American Academy of Ophthalmology. Quality of Care Committee Review Panel, Preferred Practice Pattern. Primary Open-Angle Glaucoma. San Francisco: American Academy of Ophthalmology; 1989.

    Google Scholar 

  40. Roth SM, Spaeth GL, Starita RJ, et al. The effects of postoperative corticosteroids on trabeculectomy and the clinical course of glaucoma: five-year follow-up study. Ophthalmic Surg. 1991;22:724–729.

    CAS  PubMed  Google Scholar 

  41. Zeimer RC, Wilensky JT. An instrument for self-measurement of intraocular pressure. IEEE Trans Biomed Eng. 1982;29:178.

    Article  CAS  PubMed  Google Scholar 

  42. Zeimer RC, Wilensky JT, Gieser DK, Mori MM, Baker JP. Evaluation of a self-tonometer for home use. Arch Ophthalmol. 1983;101:1791.

    CAS  PubMed  Google Scholar 

  43. Herse P, Hans A, Hall J, et al. The proview eye pressure monitor: influence of clinical factors on accuracy and agreement with the Goldmann tonometer. Ophthalmic Physiol Opt. 2005;25:416–420.

    Article  PubMed  Google Scholar 

  44. Jensen AD, Maumenee AE. Home tonometry. Am J Ophthalmol. 1973;76:929.

    CAS  PubMed  Google Scholar 

  45. Chen P, Rodger D, Saati S, Humayun M, Tai Y. Implantable parylene-based wireless intraocular pressure sensor. In: MEMS; 2008:58–61.

    Google Scholar 

  46. Backlund Y, Rosengren L, Hok B, Svedbergh B. Passive silicone transensor intended for biomedical, remote pressure monitoring. Sens Actuators. 1990;A21-A23:58–61.

    Article  Google Scholar 

  47. Eklund A, Linden C, Backlund T, et al. Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies. Med Biol Eng Comput. 2003;41:190–197.

    Article  CAS  PubMed  Google Scholar 

  48. Hallberg P, Linden C, Backlund T, Eklund A. Symmetric sensor for applanation resonance tonometry of the eye. Med Biol Eng Comput. 2006;44:54–60.

    Article  PubMed  Google Scholar 

  49. Pressure-Sensing Contact Lenses. A tiny electrical circuit built into contact lenses may provide 24-hour monitoring for glaucoma. Available at: http://www.technologyreview.com/biomedicine/21170/.

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Science+Business Media, LLC

About this chapter

Cite this chapter

Frenkel, R.E.P., Frenkel, M.P.C., Haji, S.A. (2010). Continuous Monitoring of Intraocular Pressure. In: Schacknow, P., Samples, J. (eds) The Glaucoma Book. Springer, New York, NY. https://doi.org/10.1007/978-0-387-76700-0_6

Download citation

  • DOI: https://doi.org/10.1007/978-0-387-76700-0_6

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-0-387-76699-7

  • Online ISBN: 978-0-387-76700-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics