Abstract
A 70-year-old woman was referred for possible coronary intervention for an ostial right coronary stenosis discovered during a workup for chest pain where an abnormal nuclear stress study had revealed inferior wall ischemia (Figure 6-1). The coronary intervention was performed using a 7 French Judkins right guiding catheter with predilatation of the area, followed by subsequent stent implantation of a 4.0 = 18-mm stent (Figure 6-2). An additional inflation was performed at 14atm with a short balloon to assure good stent deployment. The patient left the laboratory without any complaints, but 3 hours later, she developed some moderate chest discomfort, unlike her previous angina. She was given sublingual nitroglycerin, and subsequently developed sinus bradycardia and mild hypotension. An electrocardiogram obtained during that time was normal. She was given intravenous fluids with some response, but soon developed progressive hypotension and bradycardia. Cardiopulmonary resuscitation was begun when she lost both pulse and consciousness. Urgent echocardiography followed by bedside surgical subxyphoid exploration confirmed the suspected hemopericardium.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
USA Today. A new stent for angioplasty: use of drug-coated device is ballooning. March 4,2004:Life section.
Morice M-C, Serruys PW, Sousa JE, et al., for the RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773–1778.
Kimmel SE, Berlin JA, Strom BL, Laskey WK. Development and validation of simplified predictive index for major complications in contemporary percutaneous transluminal coronary angioplasty practice. The Registry Committee of the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol. 1995;26:931–938.
Hong MK, Popma JJ, Bairn DS, et al. Frequency and predictors of major in-hospital ischemic complications after planned and unplanned new-device angioplasty from the New Approaches to Coronary Intervention (NACI) registry. Am J Cardiol. 1997;80:40K–49K.
De Servi S, Repetto S, Bossi I, et al. Predictors of major in-hospital ischemic complications and length of hospital stay after coronary stenting. G Ital Cardiol. 1998;28:1345–1353.
Altmann DB, Racz M, Battleman DS, et al. Reduction in angioplasty complications after the introduction of coronary stents: results from a consecutive series of 2242 patients. Am Heart J. 1996;132:503–507.
Shaknovich A. Complications of coronary stenting. Coron Artery Dis. 1994;5:583–589.
Leon B, Popma JJ, Mintz GS, et al. An overview of US coronary stent trials. Semin Interv Cardiol. 1996;1:247–254.
Alfonso F, Martinez D, Hernandez R, et al. Stent embolisation during intracoronary stenting. Am J Cardiol. 1996;78:833–835.
Wong P, Leung WH. Migration of the AVE Micro coronary stent. Catheter Cardiovasc Diagn. 1996;38:267–273.
Nguyen AH, Khan A A, Chait A, Fallahnejad M. The wandering coronary stent. Case report. J Cardiovasc Surg (Torino). 1998;39:807–809.
Butman SM. Novel method of coronary stent delivery. Catheter Cardiovasc Interv. 2000;51:87–90.
Eggebrecht H, Haude M, von Birgelen C, et al. Nonsurgical retrieval of embolized coronary stents. Catheter Cardiovasc Interv. 2000;51:432–440.
Wang HJ, Kao HL, Liau CS, Lee YT. Coronary stent strut avulsion in aorto-ostial in-stent restenosis: potential complication after cutting balloon angioplasty. Catheter Cardiovasc Interv. 2002;56:215–219.
Craig WR, Aguirre FV, Kern ML Unsuspected articulation side-strut extension during stenting in a tortuous right coronary artery. Catheter Cardiovasc Diagn. 1997;42:417–419.
Esente P, Giambartolemei A, Reger MJ, et al. Extensive coronary dissection caused by balloon rupture at high pressure during stent deployment. Catheter Cardiovasc Diagn. 1996;38:263–265.
Hernandez-Antolin RA, Banuelos C, Alfonso F, et al. Successful sealing of an angioplasty-related saphenous vein graft rupture with a PTFE-covered stent. J Invasive Cardiol. 2000;12:589–593.
Kornowski R, Mehran R, Hong MK, et al. Procedural results and late clinical outcomes after placement of three or more stents in single coronary lesions. Circulation. 1998;97:1355–1361.
Wong P, Leung WH, Wong CM. Migration of the AVE Micro coronary stent. Catheter Cardiovasc Diagn. 1996;38:267–273.
Costa MA, Gigliotti OS, Zenni MM, et al. Synergistic use of sirolimus-eluting stents and intravascular ultrasound for the treatment of unprotected left main and vein graft disease. Catheter Cardiovasc Interv. 2004;61:368–375.
Sturm M, Hausmann D, Mugge A, et al. Dislodgement of a Wiktor stent during intracoronary ultrasound examination. Cardiology. 1997;88:530–532.
Sasseen BM, Burke JA, Shah R, et al. Intravascular ultrasound catheter entrapment after coronary artery stenting. Catheter Cardiovasc Interv. 2002;57:229–233.
Kirk MM, Herzog WR. Deployment of a previously embolized, unexpanded, and disarticulated Palmaz-Schatz stent. Catheter Cardiovasc Diagn. 1997;42:331–334.
Grantham JA, Tiede D, Holmes DR. Technical considerations when intervening with coronary device catheters in the vicinity of previously deployed stents. Catheter Cardiovasc Interv. 2001;52:214–217.
Thew ST, Klein LW. Report of an undeployed stent causing the unraveling of a coronary artery guidewire being used for sidebranch protection. J Invasive Cardiol. 2002;14:106–107.
Alfonso F, Perez-Vizcayno MJ, Hernandez R, et al. Clinical and angiographic implications of balloon rupture during coronary stenting. Am J Cardiol. 1997;80:1077–1080.
Cheng LC, Lee J, Chiu SW. A rare complication of PTCS: ruptured balloon with retained broken catheter. Ann Thorac Cardiovasc Surg. 2000;6:266–267.
Jain D, Hartmann F, Katus HA, Richardt G. An unusual complication of metallic balloon shaft fracture during coronary angioplasty. J Invasive Cardiol. 2001;13:314–316.
Kishi K, Hiasa Y, Takahashi T. Delayed development of a giant coronary pseudoaneurysm after stent placement for chronic total occlusion. J Invasive Cardiol. 2003;15:273–276.
Nisanci Y, Coskun I, Oncul A, Umman S. Coronary artery aneurysm development after successful primary stent implantation. Catheter Cardiovasc Diagn. 1997;42:420–422.
Karim MA. Coronary artery aneurysmal fistula: a late complication of stent deployment. Int J Cardiol. 1996;57:207–209.
Kawamura A, Asakura Y, Ishikawa S, et al. Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture. Catheter Cardiovasc Interv. 2002;57:239–243.
Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation. 2004;109:701–705.
Liistro F, Colombo A. Late acute thrombosis after paclitaxel eluting stent implantation. Heart. 2001;86:262–264.
Schomig A, Neumann FJ, Kastrati A, et al. A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents. N Engl J Med. 1996;334:1084–1089.
Schuhlen H, Hadamitzky M, Walter H, et al. Major benefit from antiplatelet therapy for patients at high risk for adverse cardiac events after coronary Palmaz-Schatz stent placement: analysis of a prospective risk stratification protocol in the Intracoronary Stenting and Antithrombotic Regimen (ISAR) trial. Circulation. 1997;95:2015–2021.
Alfonso F, Garcia-Touchard A, Lopez-Meneses M, et al. Ticlopidine pretreatment before coronary stenting is associated with sustained decrease in adverse events. Data from the Evaluation of Platelets IIb/IIIa Inhibitor for Stenting (EPISTENT) Trial. Ital Heart J Suppl. 2001;(2):805–806.
Silva JA, White CJ, Ramee SR, et al. Treatment of coronary stent thrombosis with rheolytic thrombectomy: results from a multicenter experience. Catheter Cardiovasc Interv. 2003;58:11–17.
Smith SC, Winters KJ, Lasala JM. Stent thrombosis in a patient receiving chemotherapy. Catheter Cardiovasc Diagn. 1997;40:383–386.
Danenberg HD, Lotan C, Hasin Y, et al. Acute myocardial infarction—a late complication of intracoronary stent placement. Clin Cardiol. 2000;23:376–378.
Tolerico PH, McKendall GR. Femoral endarteritis as a complication of percutaneous coronary intervention. J Invasive Cardiol. 2000;12:155–157.
Bouchart F, Dubar A, Bessou JP, et al. Pseudomonas aeruginosa coronary stent infection. Ann Thorac Surg. 1997;64:1810–1813.
Amin H, Munt B, Ignaszewski A. Staphylococcus aureus pericarditis with tamponade complicating coronary angioplasty and stenting. Can J Cardiol. 1998;14:1148–1150.
Dieter RS. Coronary artery stent infection. Clin Cardiol. 2000;23:808–810.
Liu JC, Cziperle DJ, Kleinman B, Loeb H. Coronary abscess: a complication of stenting. Catheter Cardiovasc Interv. 2003;58:69–71.
Bottner RK, Hardigan KR. Cardiac tamponade following stent implantation with adjuvant platelet IIb/IIIa receptor inhibitor administration. Catheter Cardiovasc Diagn. 1997;40:380–382.
Foster-Smith KW, Garratt KN, Higano ST, Holmes DR. Retrieval techniques for managing flexible intracoronary stent misplacement. Catheter Cardiovasc Diagn. 1993;30:63–68.
Cishek MB, Laslett L, Gershony G. Balloon catheter retrieval of dislodged coronary artery stents: a novel technique. Catheter Cardiovasc Diagn. 1995;34:350–352.
Berder V, Bedossa M, Gras D, et al. Retrieval of a lost coronary stent from the descending aorta using a PTCA balloon and biopsy forceps. Catheter Cardiovasc Diagn. 1993;28:351–353.
Patel TM, Shah SC, Gupta AK, Ranjan A. Successful retrieval of transradially delivered unexpanded coronary stent from the left main coronary artery. Indian Heart J. 2002;54:715–716.
Kaluza GL, Joseph J, Lee JR, et al. Catastrophic outcomes of noncardiac surgery soon after coronary stenting. J Am Coll Cardiol. 2000;35:1288–1294.
Wilson SH, Fasseas P, Orford JL, et al. Clinical outcome of patients undergoing non-cardiac surgery in the two months following coronary stenting. J Am Coll Cardiol. 2003;42:234–240.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2005 Springer Science+Business Media, Inc.
About this chapter
Cite this chapter
Butman, S.M. (2005). Complications Related to Coronary Stenting. In: Butman, S.M. (eds) Complications of Percutaneous Coronary Interventions. Springer, New York, NY. https://doi.org/10.1007/978-0-387-29301-1_6
Download citation
DOI: https://doi.org/10.1007/978-0-387-29301-1_6
Publisher Name: Springer, New York, NY
Print ISBN: 978-0-387-24468-6
Online ISBN: 978-0-387-29301-1
eBook Packages: MedicineMedicine (R0)