Abstract
This paper proposes a high-resolution stereoscopic surgical display using the integral videography (IV) and multiple projectors. IV projects a computer generated graphical object by multiple rays through “fly’s eye lens”, which can display geometrically accurate autostereoscopic images and reproduce motion parallax in three-dimensional (3-D) space. This technique requires neither special glasses nor sensing device to track viewer’s eyes, thus being suitable for pre-operative diagnosis and intra-operative use. This paper reports the use of multiple reduction projection display system and a parallel-calculation to achieve high-resolution IV image. We evaluate the feasibility of this display by developing a 3-D CT stereoscopic image and applying it to surgical planning and intra-operative guidance. The main contribution of this paper is application and modification of medical stereoscopic technique originally developed in high-resolution multi-projector stereoscopic display system.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
M.A. Guttman, E.R. McVeigh, “Techniques for fast stereoscopic MRI,” Magnetic Resonance in Medicines, Vol. 46, pp317–323, 2001.
M. Blackwell, C. Nikou, A.M. Digioia, T. Kanade, “An image overlay system for medical data visualization,” Medical Image Analysis, Vol. 4 pp. 67–72, 2000.
Boerner R. “Three autostereoscopic 1.25 m diagonal real projection systems with tracking features,” Proceedings ofIDW, pp. 835–838, 1997.
H. Liao, S. Nakajima, M. Iwahara, E. Kobayashi, I. Sakuma, N. Yahagi, T. Dohi, “Intraoperative Real-Time 3-D Information Display System based on Integral Videography,” Medical Image Computing and Computer assisted Intervention MICCAI2001, LNCS 2208, pp. 392–400, 2001.
M.G. Lippmann, “Epreuves reversibles donnant la sensation du relief,” J. de Phys Vol. 7, 4th series, pp821–825, 1908.
Y. Masutani et al., “Development of integral photography-based enhanced reality visualization system for surgical support,” Proc. of ISCAS’95, pp16–17, 1995.
S. Nakajima, K. Nakamura, K. Masamune, I. Sakuma, T. Dohi, “Three-dimensional medical display with computer-generated integral photography,” Computerized Medical Imaging and Graphics, 25, pp235–241, 2001.
Peter S. Pacheco, “Parallel Programming with MPI,” Morgan Kaufmann, 1996.
K. Liet al., “Building and using a scalable display wall system,” IEEE Computer Graphics and Applications, Vol. 20, Jul/Aug, Issue 4, pp. 29–37, 2000.
Y. Endo et al, “A study of antireflective and antistatic coating with ultrafine particles,” Advances Powder Technol., Vol. 7, No. 2, pp. 131–140, 1996.
H. Hoshino, F. Okano, H. Isono, I. Yuyama, “Analysis of resolution limitation of integral photography,” Optical Society of America, Vol. 15, No. 8, pp2059–2065, 1998.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Liao, H., Hata, N., Iwahara, M., Nakajima, S., Sakuma, I., Dohi, T. (2002). High-Resolution Stereoscopic Surgical Display Using Parallel Integral Videography and Multi-projector. In: Dohi, T., Kikinis, R. (eds) Medical Image Computing and Computer-Assisted Intervention — MICCAI 2002. MICCAI 2002. Lecture Notes in Computer Science, vol 2489. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-45787-9_11
Download citation
DOI: https://doi.org/10.1007/3-540-45787-9_11
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-44225-7
Online ISBN: 978-3-540-45787-9
eBook Packages: Springer Book Archive