Effect of Dyslipidemia on a Simple Morphological Feature Extracted from Photoplethysmography Flow Mediated Dilation

  • Chapter
  • First Online:
Electronic Engineering and Computing Technology

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 60))

  • 1516 Accesses

Abstract

Dyslipidemia is considered to be one of the main heart risk factors, affecting the endothelial vascular function, which can be non-invasively investigated by ultrasound flow-mediated dilation (US-FMD). However, US-FMD comes at a high-cost and is operator-dependent. In this paper, the effect of dyslipidemia on the photoplethysmogram (PPG) signal recorded from collateral index fingers is investigated following a previous study where it was shown that results similar to that of US-FMD can be replicated by the PPG. Two groups, consisting of 30 healthy subjects free from any risk factors and 30 subjects who have only dyslipidemia as risk factor were respectively considered. The percent change in the AC (peak-to-peak) values versus time of the PPG after flow release following 4 min of brachial artery blockage (reactive hyperemia) was obtained (PPG-FMD). Results indicate that a very simple morphological feature allows for a significant (p < 0. 00001) discrimination between the control and pathologic groups.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Celermajer, D.S.: Endothelial dysfunction: Does it matter? Is it reversible. J. Am. Coll. Cardiol. 30(2):325–33 (August 1997)

    Article  Google Scholar 

  2. Verma, S., Anderson, T.J.: Fundamentals of endothelial function for the clinical cardiologist. J. Am. Heart Assoc. Circulat. 105:546–549 (2002)

    Google Scholar 

  3. Meyer, B., Mörtl, D., Strecker, K., Hülsmann, M., Kulemann, V., Neunteufl, T., Pacher, R., Berger, R.: Flow-mediated vasodilation predicts outcome in patients with chronic heart failure. J. Am. Coll. Cardiol. 46(6):1011–1018 (2005)

    Article  Google Scholar 

  4. Anderson, E.A., Mark, A.L.: Flow-mediated and reflex changes in large peripheral artery tone in humans. J. Am. Heart Assoc. Circulat. 79:93–100 (1989)

    Google Scholar 

  5. Corretti, M.C., Anderson, T.J., Benjamin, E.J., Celermajer, D., Charbonneau, F., Creager, M.A., Deanfield, J., Drexler, H., Gerhard- Herman, M., Herrington, D.: Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery – a report of the international brachial artery reactivity task force. J. Am. Coll. Cardiol. 39: 257–265 (2002)

    Article  Google Scholar 

  6. Su, W., Cheng, S., Hsu, T., Ho, W.: Abnormal flow-mediated vasodilation in normal-tension glaucoma using a noninvasive determination for peripheral. Invest. Ophthalmol. Visual Sci. 47(8):3390–3394 (August 2006)

    Article  Google Scholar 

  7. Kao, Y.H., Mohler, E.R., Arger, P.H., Sehgal, C.M.: Brachial artery: measurement of flow-mediated dilation with cross sectional US-technical validation. J. Radiol. 228(3):895–900 (2003)

    Article  Google Scholar 

  8. Leeson, P., Thorne, S., Donald, A., Mullen, M., Clarkson, P., Deanfield, J.: Non-invasive measurement of endothelial function: effect on brachial artery dilatation of graded endothelial. J. Heart 78:22–27 (1997)

    Google Scholar 

  9. Zahedi, E., Jaafar, R., Mohd Ali, M.A., Mohamed, A.L., Maskon, O.: Finger photoplethysmogram pulse amplitude changes induced by flow mediated dilation. Physiol. Measure. 29(5):625–637 (2008)

    Article  Google Scholar 

  10. Allen, J.: Photoplethysmography and its application in clinical physiological measurement. J. Physiol. Measure. 28:1–39 (2007)

    Article  Google Scholar 

  11. Crabtree, V.P., Smith, P.R.: Physiological models of the human vasculature and photoplethysmography. Electron. Syst. Con. Division Res. (2003)

    Google Scholar 

  12. Zaheditochai, M., Jaafar, R., Zahedi, E.: Non-invasive techniques for assessing the endothelial dysfunction: ultrasound versus photoplethysmography. Proceedings of International Conference of Biomedical Engineering 23:65–68 (2009)

    Article  Google Scholar 

  13. Allen, J., Oates, C.P., Lees, T.A., Murray, A.: Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics. J. Physiol. Measure. 26:811–821 (2005)

    Article  Google Scholar 

  14. Zaheditochai, M., Zahedi, E., Mohd Ali, M.A.: Effect of dyslipidemia on photoplethysmography flow mediated dilation. World Congress Engineering, pp. 1881–1884 (2009)

    Google Scholar 

Download references

Acknowledgement

The authors would like to thank Universiti Kebangsaan Malaysia for supporting this work under the University Research Grant UKM-AP-TKP-07–2009.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Zaheditochai .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Science+Business Media B.V.

About this chapter

Cite this chapter

Zaheditochai, M., Zahedi, E., Ali, M.A.M. (2010). Effect of Dyslipidemia on a Simple Morphological Feature Extracted from Photoplethysmography Flow Mediated Dilation. In: Ao, SI., Gelman, L. (eds) Electronic Engineering and Computing Technology. Lecture Notes in Electrical Engineering, vol 60. Springer, Dordrecht. https://doi.org/10.1007/978-90-481-8776-8_47

Download citation

  • DOI: https://doi.org/10.1007/978-90-481-8776-8_47

  • Published:

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-90-481-8775-1

  • Online ISBN: 978-90-481-8776-8

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics