Skip to main content

Simultaneous Spatial and Velocity Vector Mapping with Diffraction Tomography

  • Chapter
Book cover Acoustical Imaging

Part of the book series: Acoustical Imaging ((ACIM,volume 23))

Abstract

Current Doppler ultrasound technology privides only two-dimensional projections of vessels or velocity patterns, is highly operator-dependent and is unable to accomplish accurate maps of the vessel lumen and flow velocity at the same time. Doppler techniques are limited in their ability to detect or measure small or deep vessels especially in the presence of slow flow, although new contrast media may enhance sensitivity. Even in superficial vessels such as the corotid artery, a very small number of pixels defines the flow channel. The aim of this study was to explore a novel diffraction tomography technique for producing quantitative, high- resolution cross-sectional Doppler images. Using this approach, a flow channel or vessel may be mapped in sequential tomograms providing a unique representation of the three- dimensional patterns of complex, curvilinear, multi-phasic or turbulent flows. The method is based on instrumentation initially developed for breast imaging1 where the value of Doppler flow data is proving valuable for breast cancer diagnosis.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. M.P. andré, H.S. Janée, G.P. Otto, P.J. Martin, B.A., et al, High-speed data acquisition in a diffraction tomography system using large-scale toroidal arrays, Intl. 1 Imaging Systems Technol. 8(1): 137(1997).

    Article  Google Scholar 

  2. S. Johnson, M.L. Tracy, Inverse scattering solutions by a sine basis, multiple source, moment method — Part I: Theory, Ultrasonic Imaging 5:361(1983).

    Google Scholar 

  3. M.P. andré, H.S. Janée, G.P. Otto, P.J. Martin, Reduction of phase aberration in a diffraction tomography system for breast imaging. Acoustical Imaging 22:151(1996).

    Article  Google Scholar 

  4. R.O. Schmidt, Multiple emitter location and signal parameter estimation. IEEE Trans. Ant. & Prog. 14:276 (1986).

    Article  ADS  Google Scholar 

  5. S.F. Gull, G.J. Daniell, Image reconstruction from incomplete and noisy data. Nature 272:686(1978).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1997 Springer Science+Business Media New York

About this chapter

Cite this chapter

andré, M.P., Janée, H.S., Barrett, T.K., Spivey, B.A., Martin, P.J. (1997). Simultaneous Spatial and Velocity Vector Mapping with Diffraction Tomography. In: Lees, S., Ferrari, L.A. (eds) Acoustical Imaging. Acoustical Imaging, vol 23. Springer, Boston, MA. https://doi.org/10.1007/978-1-4419-8588-0_91

Download citation

  • DOI: https://doi.org/10.1007/978-1-4419-8588-0_91

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-4640-1

  • Online ISBN: 978-1-4419-8588-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics