Abstract
The influence of thermal hysteresis of the comparator on the sensitivity of signal converter and distortions of the zero line at various comparator type equivalent time signal conversion methods is studied. The research is carried out by statistical simulations and physical experiments. In the simulations two sets of parameters of the thermal hysteresis are used: one appropriate to parameters of experimental device, and the second—appropriate to comparator with a stronger thermal hysteresis.
Similar content being viewed by others
References
Souders, T.M., Shoenwetter, H.K., and Hetrick, P.S., Characterisation of a sampling voltage tracker for measuring fast repetitive signals, IEEE Trans. Instrum. Meas., 1987, vol. 36, pp. 956–960.
Souders, T.M. and Hetrick, P.S., Accurate RF voltage measurement using a sampling voltage tracker IEEE Trans. Instrum. Meas., 1989, vol. 38, pp. 451–456.
Laug, O.B., Souders, T.M., and Flach, D.R., Custom integrated circuit comparator for high-performance sampling applications IEEE Trans. Instrum. Measur., 1992, vol. 41, no. 6, pp. 850–855.
Bergman, D.I., An accurate pulse measurement system for real-time oscilloscope calibration. NCSLI measure J. Measur. Sci., 2006, vol. 1, no. 3, pp. 22–29.
Laug, O.B., Bergman, D.I., Souders, T.M., and Waltrip, B.C., A next generation sampling comparator probe for the NIST sampling waveweform analyser, NIST Tech. Note, 2008, no. 1496.
Ye, Sh., Zhou, B., and Fang, G., Design of a novel ultrawideband digital receiver for pulse ground-penetrating radar IEEE Geosci. Remote Sens. Lett., 2011, vol. 8, no. 4.
Ye, Sh., Chen, J., Liu, L., Zhang, Ch., and Fang, G., A novel compact UWB ground penetrating radar system, 14th International Conference on Ground Penetrating Radar (GPR), Shanghai, 2012.
Agafonovs, N. and Supols, G., Design and evaluation of a stroboscopic signal converter based on discrete transistor clocked comparator 13th Biennial Baltic Electronics Conference (BEC2012), Tallinn, 2012, pp. 69–73.
Krumin’sh, K., Peterson, V., and Plotsin’sh, V., The influence of thermal hysteresis of a clocked comparator on the operation of the comparator type sampling converter Autom. Control Comput. Sci., 2015, vol. 49, no. 4, pp. 245–253.
Kruminsh, K. and Plotsinsh, V., Speed of operation of equivalent time methods for conversion of noisy signals: A review Autom. Control Comput. Sci., 2013, vol. 47, no. 6, pp. 318–325.
Krūmiš, K. and Krkliš, V., Modification of up-and-down method in the mode of detecting weak signals of superwideband radar Autom. Control Comput. Sci., 2005, vol. 39, no. 4, pp. 58–64.
Kruminsh, K. and Plotsinsh, V., Adaptive k-up-and-down method for comparator type equivalent time conversion of UWB radar signals Autom. Control Comput. Sci., 2012, vol. 46, no. 6.
Krūmiš, K., Noisy signal tracking in the sampling converter by the “up-and-down” method 1995 Workshop on Sampling Theory & Applications, Jurmala, 1995, pp. 215–218.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
About this article
Cite this article
Krumin’sh, K., Peterson, V. & Plotsin’sh, V. Influence of thermal hysteresis on distortions of zero line at various comparator type equivalent time signal conversion methods. Aut. Control Comp. Sci. 50, 20–27 (2016). https://doi.org/10.3103/S0146411616010053
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3103/S0146411616010053