Skip to main content
Log in

Influence of thermal hysteresis on distortions of zero line at various comparator type equivalent time signal conversion methods

  • Published:
Automatic Control and Computer Sciences Aims and scope Submit manuscript

Abstract

The influence of thermal hysteresis of the comparator on the sensitivity of signal converter and distortions of the zero line at various comparator type equivalent time signal conversion methods is studied. The research is carried out by statistical simulations and physical experiments. In the simulations two sets of parameters of the thermal hysteresis are used: one appropriate to parameters of experimental device, and the second—appropriate to comparator with a stronger thermal hysteresis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Souders, T.M., Shoenwetter, H.K., and Hetrick, P.S., Characterisation of a sampling voltage tracker for measuring fast repetitive signals, IEEE Trans. Instrum. Meas., 1987, vol. 36, pp. 956–960.

    Article  Google Scholar 

  2. Souders, T.M. and Hetrick, P.S., Accurate RF voltage measurement using a sampling voltage tracker IEEE Trans. Instrum. Meas., 1989, vol. 38, pp. 451–456.

    Article  Google Scholar 

  3. Laug, O.B., Souders, T.M., and Flach, D.R., Custom integrated circuit comparator for high-performance sampling applications IEEE Trans. Instrum. Measur., 1992, vol. 41, no. 6, pp. 850–855.

    Article  Google Scholar 

  4. Bergman, D.I., An accurate pulse measurement system for real-time oscilloscope calibration. NCSLI measure J. Measur. Sci., 2006, vol. 1, no. 3, pp. 22–29.

    Google Scholar 

  5. Laug, O.B., Bergman, D.I., Souders, T.M., and Waltrip, B.C., A next generation sampling comparator probe for the NIST sampling waveweform analyser, NIST Tech. Note, 2008, no. 1496.

  6. Ye, Sh., Zhou, B., and Fang, G., Design of a novel ultrawideband digital receiver for pulse ground-penetrating radar IEEE Geosci. Remote Sens. Lett., 2011, vol. 8, no. 4.

  7. Ye, Sh., Chen, J., Liu, L., Zhang, Ch., and Fang, G., A novel compact UWB ground penetrating radar system, 14th International Conference on Ground Penetrating Radar (GPR), Shanghai, 2012.

    Google Scholar 

  8. Agafonovs, N. and Supols, G., Design and evaluation of a stroboscopic signal converter based on discrete transistor clocked comparator 13th Biennial Baltic Electronics Conference (BEC2012), Tallinn, 2012, pp. 69–73.

    Chapter  Google Scholar 

  9. Krumin’sh, K., Peterson, V., and Plotsin’sh, V., The influence of thermal hysteresis of a clocked comparator on the operation of the comparator type sampling converter Autom. Control Comput. Sci., 2015, vol. 49, no. 4, pp. 245–253.

    Article  Google Scholar 

  10. Kruminsh, K. and Plotsinsh, V., Speed of operation of equivalent time methods for conversion of noisy signals: A review Autom. Control Comput. Sci., 2013, vol. 47, no. 6, pp. 318–325.

    Article  Google Scholar 

  11. Krūmiš, K. and Krkliš, V., Modification of up-and-down method in the mode of detecting weak signals of superwideband radar Autom. Control Comput. Sci., 2005, vol. 39, no. 4, pp. 58–64.

    Google Scholar 

  12. Kruminsh, K. and Plotsinsh, V., Adaptive k-up-and-down method for comparator type equivalent time conversion of UWB radar signals Autom. Control Comput. Sci., 2012, vol. 46, no. 6.

    Google Scholar 

  13. Krūmiš, K., Noisy signal tracking in the sampling converter by the “up-and-down” method 1995 Workshop on Sampling Theory & Applications, Jurmala, 1995, pp. 215–218.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Krumin’sh.

Additional information

The article is published in the original.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Krumin’sh, K., Peterson, V. & Plotsin’sh, V. Influence of thermal hysteresis on distortions of zero line at various comparator type equivalent time signal conversion methods. Aut. Control Comp. Sci. 50, 20–27 (2016). https://doi.org/10.3103/S0146411616010053

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S0146411616010053

Keywords

Navigation