Asymmetric flat-sheet membranes made of poly(vinyltrimethylsilane) (PVTMS) were studied for the regeneration of amine-based absorption solvents in a membrane gas-liquid contactor at 100°C. It was shown that PVTMS membrane possesses good mechanical and chemical stability in contact with 4 M monoethanolamine (MEA) and 2 M potassium taurate (PT) solution at 100°C for 250 hours. No liquid penetration through PVTMS was observed during 6 days of continuous testing at a liquid overpressure of 0.55 bar. Storing of PVTMS at 100°C in contact with air for a period of 3 months did not lead to dramatic changes in membrane gas permeability. Membrane gas desorption experiments showed that degradation of loaded MEA leads to membrane fouling, resulting in a decline of membrane performance within 6 days. However, membrane gas desorption experiments with loaded potassium taurate solution did not lead to any noticeable changes of the membrane, and, hence, stable performance of the PVTMS based membrane was observed. Comparing a porous PTFE membrane with an asymmetric PVTMS with dense selective layer shows that the solvent evaporation is at least a factor of 20 lower for the PVTMS membrane; while both porous and non-porous membranes exhibit comparable CO2 flux indicating that overall resistance of desorption process is mainly governed by the reverse chemical reactions and mass-transfer resistance in the liquid phase.
Similar content being viewed by others
References
M. R. M. Abu-Zahra, L. H. J. Schneiders, J. P. M. Niederer, P. H. M. Feron, and G. F. Versteeg, “CO2 capture from power plants Part I. A parametric study of the technical performance based on monoethanolamine,” Int. J. Greenh. Gas Con. 1, 37 (2007).
Z. Qi and E. L. Cussler, “Microporous hollow fibers for gas absorption. II. Mass transfer across the membrane,” J. Membr. Sci. 23, 333 (1985).
P. H. M. Feron and A. E. Jansen, “CO2 separation with polyolefin membrane contactors and dedicated absorption liquids: performances and prospects,” Sep. Purif. Technol. 27, 231 (2002).
D. deMontigny, P. Tontiwachwuthikul, and A. Chakma, “Comparing the absorption performance of packed columns and membrane contactors,” Ind. Eng. Chem. Res. 44, 5726 (2005).
P. H. M. Feron and A. E. Jansen, “Capture of carbon dioxide using membrane gas absorption and reuse in the horticultural industry,” Energy Convers. Manag. 36, 411 (1995).
E. Chabanon, D. Roizard, and E. Favre, “Membrane contactors for post-combustion carbon dioxide capture: a comparative study of wetting resistance on long time scales,” Ind. Eng. Chem. Res. 50, 8237 (2011).
L. Wang, Zh. Zhang, B. Zhao, H. Zhang, X. Lu, and Q. Yang, “Effect of long-term operation on the performance of polypropylene and polyvinylidene fluoride membrane contactors for CO2 absorption,” Sep. Purif. Technol. 116, 300 (2013).
S. Khaisri, D. deMontigny, P. Tontiwachwuthikul, and R. Jiraratananon, “Comparing membrane resistance and absorption performance of three different membranes in a gas absorption membrane contactor,” Sep. Purif. Technol. 65, 290 (2009).
H. Kreulen, C. A. Smolders, G. F. Versteeg, and W. P. M. van Swaaij, “Determination of mass transfer rates in wetted and non-wetted microporous membranes,” Chem. Eng. Sci. 48, 2093 (1993).
A. Malek, K. Li, and W. K. Teo, “Modelling of microporous hollow fibre membrane modules operated under partially wetted conditions,” Ind. Eng. Chem. Res. 36, 784 (1997).
R. Wang, H. Y. Zhang, P. H. M. Feron, and D. T. Liang, “Influence of membrane wetting on CO2 capture in CO2 + PV microporous hollow fiber membrane contactors,” Sep. Purif. Technol. 46, 33 (2005).
Yu. Lv, X. Yua, Sh.-T. Tua, J. Yan, and E. Dahlquist, “Wetting of polypropylene hollow fiber membrane contactors,” J. Membr. Sci. 362, 444 (2010).
H. Kumazawa, “Absorption and desorption of CO2 by aqueous solutions of sterically hindered 2-amino-2methyl-1-propanol in hydrophobic microporous hollow fiber contained contactors,” Chem. Eng. Commun. 182, 163 (2000).
S. Khaisri, D. deMontigny, P. Tontiwachwuthikul, and R. Jiraratananon, “CO2 stripping from monoethanolamine using a membrane contactor,” J. Membr. Sci. 376, 110 (2011).
M. Simioni, S. E. Kentish, and G. W. Stevens, “Membrane stripping: Desorption of carbon dioxide from alkali solvents,” J. Membr. Sci. 378, 18 (2011).
Zh. Wang, M. Fang, Y. Pan, Sh. Yan, and Zh. Luo, “Amine-based absorbents selection for CO2 membrane vacuum regeneration technology by combined absorption–desorption analysis,” Chem. Eng. Sci. 93, 238 (2013).
K. Okabe, H. Mano, and Y. Fujioka, “Separation and recovery of carbon dioxide by a membrane flash process,” Int. J. Greenh. Gas Con. 2, 485 (2008).
M. Fang, Zh. Wang, Sh. Yana, Q. Cen, and Zh. Luo, “CO2 desorption from rich alkanolamine solution by using membrane vacuum regeneration technology,” Int. J. Greenh. Gas Con. 9, 507 (2012).
S. Koonaphapdeelert, Zh. Wu, and K. Li, “Carbon dioxide stripping in ceramic hollow fibre membrane contactors,” Chem. Eng. Sci. 64, 1 (2009).
K. Simons, K. Nijmeijer, H. Mengers, W. Brilman, and M. Wessling, “Highly selective amino acid salt solutions as absorption liquid for CO2 capture in gas–liquid membrane contactors,” Chem. Sus. Chem. 3, 939 (2010).
V. V. Usachov, V. V. Teplyakov, A. Y. Okunev, and N. I. Laguntsov, “Membrane contactor air conditioning system: Experience and prospects,” Sep. Purif. Technol. 57, 502 (2007).
M. G. Shalygin, D. Roizard, E. Favre, and V. V. Teplyakov, “CO2 transfer in an aqueous potassium carbonate liquid membrane module with dense polymeric supporting layers: Influence of concentration, circulation flow rate and temperature,” J. Membr. Sci. 318, 317 (2008).
K. Simons, K. Nijmeijer, and M. Wessling, “Gas-liquid contactors for CO2 removal,” J. Membr. Sci. 340, 214 (2009).
A. Trusov, S. Legkov, L. J. P. van den Broeke, E. Goetheer, V. Khotimsky, and A. Volkov, “Gas/liquid membrane contactors based on disubstituted polyacetylene for CO2 absorption liquid regeneration at high pressure and temperature,” J. Membr. Sci. 383, 241 (2011).
M. G. Shalygin, A. V. Yakovlev, V. S. Khotimskii, L. G. Gasanova, and V. V. Teplyakov, “Membrane contactors for biogas conditioning,” Petroleum Chemistry 51, 601 (2011).
A. A. Lysenko, S. D. Bazhenov, V. P. V. Asilevsky, E. G. Novitsky, and A. V. Volkov, “Membrane regeneration of aqueous solution of monoethanolamine,” Membrany i Membranie Technologii (2), 1 (2012) [in Russian].
A. A. Shutova, A. N. Trusov, M. V. Bermeshev, S. A. Legkov, M. L. Gringolts, E. Sh. Finkelstein, G. N. Bondarenko, and A. V. Volkov, “Regeneration of alkanolamine solutions in membrane contactor based on novel polynorbornene,” Oil & Gas Science and Technology—Rev. IFP Energies nouvelles. 69, 1059 (2014).
P. H. M. Feron, V. V. Volkov, V. S. Khotimsky, V. V. Teplyakov, (2006) Membrane gaz separation, WO2006004400
V. I. Roldugin, A. A. Shutova, A. V. Volkov, E. L. V. Goetheer, and V. V. Volkov, “Kinetics of carbon dioxide removal from water in flat membrane contactor,” Petrol. Chem. 54, 507 (2014).
A. M. Grekhov, Y. S. Eremin, G. A. Dibrov, and V. V. Volkov, “Percolation of composite poly(vinyltrimethylsilane) membranes with carbon nanotubes,” Petrol. Chem. 53, 549 (2013).
Yu. P. Yampolskii and V. V. Volkov, “Studies in gas permeability and membrane gas separation in the Soviet Union,” J. Membr. Sci. 64, 191 (1991).
Author information
Authors and Affiliations
Corresponding author
Additional information
The article was translated by the authors.
Original Russian Text © A.V. Volkov, S.E. Tsarkov, E.L.V. Goetheer, V.V. Volkov, 2015, published in Membrany i Membrannye Tekhnologii, 2015, Vol. 5, No. 3, pp. 192–201.
Rights and permissions
About this article
Cite this article
Volkov, A.V., Tsarkov, S.E., Goetheer, E.L.V. et al. Amine-based solvents regeneration in gas-liquid membrane contactor based on asymmetric PVTMS. Pet. Chem. 55, 716–723 (2015). https://doi.org/10.1134/S0965544115090078
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0965544115090078