A single-use Hg(II) patch biosensor has been developed consisting of 1.25-cm diameter patches of two acrylic vinyl acetate copolymer layers coated on polyester. The top layer copolymer was 47 μm thick whereas the bottom layer of copolymer plus E. coli cells was 30 μm thick. The immobilized E. coli HB101 cells harbored a mer-lux plasmid construct and produced a detectable light signal when exposed to Hg(II). The immobilized-cell Hg(II) biosensor had a sensitivity similar to that of suspended cells but a significantly larger detection range. The levels of mercury detected by the patches ranged from 0.1 nM to 10 000 nM HgCl2 in pyruvate buffer, and luciferase induction as a function of Hg(II) concentration was sigmoidal. Luciferase activity was detected in immobilized cells for more than 78 h after exposure of the cells to HgCl2. Addition of 1 mM D-cysteine to the pyruvate buffer increased luciferase induction more than 100-fold in the immobilized cell patches and 3.5-fold in a comparable suspension culture. The copolymer patches with immobilized cells were stable at −20°C for at least 3 months, and the Hg(II)-induced luciferase activity after storage was similar to that of samples assayed immediately after coating. Patches stored desiccated at room temperature for 2 weeks showed lower mercury-induced luciferase activity when compared to freshly prepared patches, but they still had a considerable detection range of 1 to 10 000 nM HgCl2.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 05 November 1998/ Accepted in revised form 08 April 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lyngberg, O., Stemke, D., Schottel, J. et al. A single-use luciferase-based mercury biosensor using Escherichia coli HB101 immobilized in a latex copolymer film. J Ind Microbiol Biotech 23, 668–676 (1999). https://doi.org/10.1038/sj.jim.2900679

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1038/sj.jim.2900679

Navigation