Abstract

The aim of the work is to find the best solution for statistical sampling technique in validation of radiation sterilization dose (RSD) for biological tissues, according to ISO standard. As a model for sampling are biological tissues retrieved from one cadaver donor which consist of frozen bone grafts (18 packets), lyophilized allografts (68 packets) and demineralized bone powder grafts (40 packets). The size and type of products vary from long bones, cancellous chips to bone powders, tendons and facia lata, that make the number of bioburden per product could not be treated equally. Frozen samples could not be considered as the same production batch with lyophilized samples, because of different processing and irradiation temperature. The minimum number of uniformed samples needed for validation per production batch size, according to ISO 13409, is from 20 to 79 and 20 of them will be used for the test sample size, i.e. 10 for bio-burden determination and the remaining 10 for verification dose. Based on the number of uniformed grafts, statistical sampling can be carried out on lyophilized and demineralized bone grafts, but not on frozen bone grafts. Bioburden determinations were carried out and validated according to ISO 11737-1. Results of average bioburden determination (cfu/per packet), using sample item portion (SIP) = 1, are 5 cfu/packet for lyophilized bone grafts and 4 cfu/packet for demineralized bone powder grafts. Verification doses obtained were 2.40 kGy for lyophilized grafts and 2.24 kGy for demineralized bone powder grafts. The results of verification dose were accepted and the RSD of 25 kGy is substantiated It can be concluded that a statistical sampling technique can be applied if all the grafts produced in the same process such as lyophilized, demineralized as well as frozen are assumed to be in one production batch regardless of sample uniformity such as size, type and weight; for this ISO 13409 can be applied for the validation of RSD.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • AAMI Technical Information Report (TIR 27) (2001) Sterilization of health care products-radiation sterilization-substantiated of 25 kGy as sterilization dose, Virginia, U.S.A.

  • American Association of Tissue Banks (AATB) (2002) Standards for Tissue Banking, McLean, Virginia, U.S.A.

    Google Scholar 

  • Brynjolfsson A(1978) Mathematical model for microbial killing by radiation. In: Food Preservation by Irradiation, Vol 1, pp 227-139, IAEA, Vienna

    Google Scholar 

  • Dziedzic-Goclawska A, Ostrowski K, Stachowicz W, Michalik J and Grzesik W (1991) Effect of radiation sterilization on osteoinductive properties and the rate of remodeling of bone implants preserved by lyophilization and deep freezing. Clin Orthop Rel Res 272: 30-37

    Google Scholar 

  • Dziedzic-Goclawska A and Stachowicz W (1997) Sterilization of tissue allografts. In: Phillips GO (ed) Advances inTissue Banking, Vol 1, pp 261-321, World Scientific, Singapore

    Google Scholar 

  • European Association of Tissue Banking (EATB) and European Association for Muscular Skeletal Tissue (EAMST) (1997) Common Standards for Muscular Skeletal Tissue Banking, OBIG Transplant, Vienna

    Google Scholar 

  • European Association of Tissue Banks (EATB) (1994) General Standards for Tissue Banking, OBIG Transplant, Vienna 1032-1035

    Google Scholar 

  • Hilmy N (1998) Benefits of ionizing radiation to increase hygienic quality of medical devices, pharmaceutical products and their raw materials, food products and their environment. Quart J Indonesian Nucl Soc 1(1): 69-80

    Google Scholar 

  • Hilmy N, Febrida A and Basril A (2000) J Cell Tissue Bank 1(2): 143-147

    Google Scholar 

  • Hilmy N and Lina M (2001) Effects of ionising radiation on viruses, proteins and prions. In: Phillips GO (ed) Advances in Tissue Banking, Vol 5, pp 358-375, World Scientific, Singapore

    Google Scholar 

  • International Atomic Energy Agency (IAEA) (1997) Multi-Media Distance Learning Package on Tissue Banking, Module 4, Procurement. IAEA/NUS Regional Training Centre (RCA), IAEA/NUS Interregional Training Centre, Singapore

    Google Scholar 

  • International Atomic Energy Agency (IAEA) (2002) International Standards for Tissue Banks, IAEA, Vienna

    Google Scholar 

  • International Atomic Energy Agency (IAEA) 2002 Code of Practice for the Radiation Sterilization of Tissue Allografts, IAEA, Vienna

    Google Scholar 

  • ISO 11137 (1995) Sterilization of health care products-requirements for validation and routine control-radiation sterilization. International Organization for Standardization, Geneva

    Google Scholar 

  • ISO 11737-1 (1995) Sterilization of medical devices-microbiological methods. Part 1: Estimation of population of microorganisms on products, International Organization for Standardization, Geneva

    Google Scholar 

  • ISO 11737-2 (1998) Sterilization of medical devices-microbiological methods. Part 2: Sterility test of microorganisms on products, International Organization for Standardization, Geneva

    Google Scholar 

  • ISO 13409 (1996) Sterilization of health care products-radiation sterilization-substantiation of 25 kGy as sterilization dose for small or infrequent production batches. International Organization for Standardization, Geneva

    Google Scholar 

  • Sokal RR (1979) Biometry, 1st edition, Freeman & Co, New York

    Google Scholar 

  • Wills PA, Saunders M and Izard M (1980) Microbiological aspects for radiation sterilization of pharmaceuticals and related products. Report on IAEA Coordinated Meeting on Radiation Sterilization, Sydney, Australia

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hilmy, N., Basril, A. & Febrida, A. Indonesia: Statistical Sampling Technique in Validation of Radiation Sterilisation Dose of Biological Tissue. Cell Tissue Banking 4, 185–191 (2003). https://doi.org/10.1023/B:CATB.0000007031.38240.8f

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/B:CATB.0000007031.38240.8f

Navigation