Design and construction of a multi-sensor position monitoring system applied to key components of synchrotron sources

  • Published:
Nuclear Science and Techniques Aims and scope Submit manuscript

Abstracts

High-accuracy position monitoring of key components is required for modern synchrotron sources, such as free-electron lasers and diffraction-limited storage rings. Although various position monitoring sensors have been adopted to monitor the displacement of key components in each direction in real time, these monitoring systems are usually based on their own coordinate system. Data from such systems are meaningful when evaluating and examining the data from each positioning monitoring system in a unified coordinate system. This paper presents the design and construction of a multi-sensor position monitoring system (MPMS). A hydrostatic levelling system, a wire position sensor (WPS) and a tiltmeter are fixed to a stainless steel plate that has been calibrated by a coordinate-measurement machine. Several plates form the MPMS. The system must compensate for the sag of the stretched wires so that the WPSs create a straight line. The method of the coordinate transformation from the sensor coordinate system to the MPMS coordinate system was thoroughly studied. An experimental MPMS that includes five plates was setup in a 20-m tunnel, and a validation study to verify fully the feasibility of the MPMS was performed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. X.Y. He, W. Wang, P. Wang et al., Alignment control network scheme design and measurement of HLS upgrade. Nucl. Tech. 36, 100102 (2013). doi:10.11889/j.0253-3219.2013.hjs.36.100102. (in Chinese)

    Google Scholar 

  2. H. Andreas, M.D. Hélène, M. Antonio, Test and calibration facility for HLS and WPS sensors. in Proceedings of the 8th International Workshop on Accelerator Alignment (CERN, Geneva, 2004)

  3. H.Y. Zhu, L. Dong, L.L. Men et al., Alignment of ADS beta cryostat with wire position monitor. Nucl. Sci. Tech. 26, 040401 (2015). doi:10.13538/j.1001-8042/nst.26.040401

    Google Scholar 

  4. T. Touzé, Feasibility of the CLIC metrological reference network. in Proceedings of the 11th International Workshop on Accelerator Alignment (DESY, Hamburg, 2010)

  5. M.D. Hélène, CLIC active pre-alignment system: proposal for CDR and program for TDR. in Proceedings of the 8th International Workshop on Accelerator Alignment (CERN, Geneva, 2004)

  6. D. Schulte, Pre-alignment needs for CLIC. in CLIC Pre-alignment workshop 2009 (CERN, Geneva, 2009)

  7. S.F. Xu, X.Y. He, X.D. Chen et al., Tidal effects on hydrostatic leveling system used in high precision alignment of particle accelerator. Nucl. Sci. Tech. 25, 040102 (2014). doi:10.13538/j.1001-8042/nst.25.040102

    Google Scholar 

  8. T. Shintake, M. Tejima, H. Ishii et al., Sensitivity calculation of beam position monitor using boundary element method. Nucl. Instrum. Methods A 254, 146–150 (1987). doi:10.1016/0168-9002(87)90496-7

    Article  Google Scholar 

  9. D.E. Beers, J.E. Ramirez, Vectran: high-performance fibre. J. Text. Inst. 81(4), 561–574 (1990). doi:10.1080/00405009008658729

    Article  Google Scholar 

  10. Z.X. Zhu, K.F. Yao, Engineering Meterials (High Education Press, Beijing, 2006), pp. 167–170

    Google Scholar 

  11. L.Y. Tian, J.P. Yue, H. Mei, Engineer Control Survey (Wuhang University Press, Wuhang, 2011), pp. 112–113. (in Chinese)

    Google Scholar 

  12. C.F. Ma, W.C. Ling, Modern Numerical Calculation Method (Science Press, Beijing, 2008), pp. 79–86. (in Chinese)

    Google Scholar 

  13. G.Y. Li, Z.C. Li, The Principles and Applications of Industrial Measuring Systems (Geodesy Press, Beijing, 2011), pp. 287–289. (in Chinese)

    Google Scholar 

  14. T. Touzé. Ph.D. Thesis, Université de Paris-Est (2011)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiao-Ye He.

Additional information

This work was supported by the National Natural Science Foundation of China (No. 11275192) and the upgrade project of Hefei Light Source.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, W., Tang, Z., He, XY. et al. Design and construction of a multi-sensor position monitoring system applied to key components of synchrotron sources. NUCL SCI TECH 27, 134 (2016). https://doi.org/10.1007/s41365-016-0132-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41365-016-0132-4

Keywords

Navigation