High-accuracy position monitoring of key components is required for modern synchrotron sources, such as free-electron lasers and diffraction-limited storage rings. Although various position monitoring sensors have been adopted to monitor the displacement of key components in each direction in real time, these monitoring systems are usually based on their own coordinate system. Data from such systems are meaningful when evaluating and examining the data from each positioning monitoring system in a unified coordinate system. This paper presents the design and construction of a multi-sensor position monitoring system (MPMS). A hydrostatic levelling system, a wire position sensor (WPS) and a tiltmeter are fixed to a stainless steel plate that has been calibrated by a coordinate-measurement machine. Several plates form the MPMS. The system must compensate for the sag of the stretched wires so that the WPSs create a straight line. The method of the coordinate transformation from the sensor coordinate system to the MPMS coordinate system was thoroughly studied. An experimental MPMS that includes five plates was setup in a 20-m tunnel, and a validation study to verify fully the feasibility of the MPMS was performed.
Similar content being viewed by others
References
X.Y. He, W. Wang, P. Wang et al., Alignment control network scheme design and measurement of HLS upgrade. Nucl. Tech. 36, 100102 (2013). doi:10.11889/j.0253-3219.2013.hjs.36.100102. (in Chinese)
H. Andreas, M.D. Hélène, M. Antonio, Test and calibration facility for HLS and WPS sensors. in Proceedings of the 8th International Workshop on Accelerator Alignment (CERN, Geneva, 2004)
H.Y. Zhu, L. Dong, L.L. Men et al., Alignment of ADS beta cryostat with wire position monitor. Nucl. Sci. Tech. 26, 040401 (2015). doi:10.13538/j.1001-8042/nst.26.040401
T. Touzé, Feasibility of the CLIC metrological reference network. in Proceedings of the 11th International Workshop on Accelerator Alignment (DESY, Hamburg, 2010)
M.D. Hélène, CLIC active pre-alignment system: proposal for CDR and program for TDR. in Proceedings of the 8th International Workshop on Accelerator Alignment (CERN, Geneva, 2004)
D. Schulte, Pre-alignment needs for CLIC. in CLIC Pre-alignment workshop 2009 (CERN, Geneva, 2009)
S.F. Xu, X.Y. He, X.D. Chen et al., Tidal effects on hydrostatic leveling system used in high precision alignment of particle accelerator. Nucl. Sci. Tech. 25, 040102 (2014). doi:10.13538/j.1001-8042/nst.25.040102
T. Shintake, M. Tejima, H. Ishii et al., Sensitivity calculation of beam position monitor using boundary element method. Nucl. Instrum. Methods A 254, 146–150 (1987). doi:10.1016/0168-9002(87)90496-7
D.E. Beers, J.E. Ramirez, Vectran: high-performance fibre. J. Text. Inst. 81(4), 561–574 (1990). doi:10.1080/00405009008658729
Z.X. Zhu, K.F. Yao, Engineering Meterials (High Education Press, Beijing, 2006), pp. 167–170
L.Y. Tian, J.P. Yue, H. Mei, Engineer Control Survey (Wuhang University Press, Wuhang, 2011), pp. 112–113. (in Chinese)
C.F. Ma, W.C. Ling, Modern Numerical Calculation Method (Science Press, Beijing, 2008), pp. 79–86. (in Chinese)
G.Y. Li, Z.C. Li, The Principles and Applications of Industrial Measuring Systems (Geodesy Press, Beijing, 2011), pp. 287–289. (in Chinese)
T. Touzé. Ph.D. Thesis, Université de Paris-Est (2011)
Author information
Authors and Affiliations
Corresponding author
Additional information
This work was supported by the National Natural Science Foundation of China (No. 11275192) and the upgrade project of Hefei Light Source.
Rights and permissions
About this article
Cite this article
Wang, W., Tang, Z., He, XY. et al. Design and construction of a multi-sensor position monitoring system applied to key components of synchrotron sources. NUCL SCI TECH 27, 134 (2016). https://doi.org/10.1007/s41365-016-0132-4
Received:
Revised:
Accepted:
Published:
DOI: https://doi.org/10.1007/s41365-016-0132-4