Abstract
Voltage sags are disturbances that deserve special attention in power quality (PQ) area, given its frequent occurrences. Their constant monitoring is, therefore, essential to diagnose its causes and mitigate economic losses of electric utility customers. However, the cost of a monitoring system may be excessive if not evaluated strategically. In this context, this work presents an algorithm for the installation of PQ monitors at strategic points of electric power distribution systems in order to diagnose voltage sags. Observability area concept and binary particle swarm optimization method were used to evaluate the problem. A sensitivity analysis was also performed, in which the influence of several parameters, such as fault resistance, system loading, detection threshold, fault type, and system expansion, was evaluated. The algorithm was validated in a Brazilian distribution system and in IEEE 34-bus system. The results indicated that the algorithm was able to detect voltage sags throughout the system using monitors at few buses, reducing the cost of the monitoring system.
Similar content being viewed by others
References
Almeida, C. F. M. (2007). Methodology for the efficient monitoring of short duration voltage variations in power systems. Master’s thesis (in Portuguese).
Bertho, R. et al. (2016). Optimized power quality monitor placement based on a particle swarm optimization algorithm. In 2016 17th international conference on harmonics and quality of power (ICHQP) (pp. 115–119).
Costa, F. B., Souza, B. A. & Brito, N. S. D. (2010). Realtime detection of voltage sags based on wavelet transform. In 2010 IEEE/PES transmission and distribution conference and exposition: Latin America (TD-LA) (pp. 537–542).
Daubechies, I. (1992). Ten lectures on wavelets. CBMS-NSF regional conference series. Philadelphia: SIAM.
Dugan, R. C., et al. (2004). Electrical power systems quality (2nd ed.). New York: McGraw-Hill.
Eldery, M. A., El-Saadany, F. & Salama, M. M. A. (2004). Optimum number and location of power quality monitors. In 11th international conference on harmonics and quality of power (pp. 50–57).
EPRI. (2003). Distribution system power quality assessment: Phase II. Voltage sag and interruption analysis (pp. 5–17). Palo Alto: Electric Power Research Institute.
Ibrahim, A. A., et al. (2012). A new approach for optimal power quality monitor placement in power system considering system topology. Przeglad Elektrotechniczny, 88, 272–276.
IEEE. (2010). IEEE 34 node test feeder. Power System Analysis, Computing and Economics Committee.
IEEE. (2014). IEEE guide for voltage sag indices. IEEE P1564/D19 (pp. 1–55).
Juarez, E. E., Hernandez, A., & Olguin, G. (2009). An approach based on analytical expressions for optimal location of voltage sags monitors. IEEE Transactions on Power Delivery, 24(4), 2034–2042.
Kazemi, A., et al. (2013). Review of power quality monitor placement methods in transmission and distribution systems. Przeglad Elektrotechniczny, 89, 185–188.
Kennedy, J. & Eberhart, R. (1995). Particle swarm optimization. In Proceedings, IEEE international conference on neural networks (Vol. 4, pp. 1942–1948).
Khanesar, M. A., Teshnehlab, M., & Shoorehdeli, M. A. (2007). A novel binary particle swarm optimization. In Mediterranean conference on control automation, 2007. MED ’07 (pp. 1–6).
Mali, V. P., Chakrasali, R. L., & Aprameya, K. S. (2015). A technical investigation of voltage sag. American Journal of Engineering Research (AJER), 4(10), 60–68.
Mallat, S. G. (1989). A theory for multiresolution signal decomposition: The wavelet representation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 11(7), 674–693.
Martins, P. E. T., et al. (2018). Optimized allocation of power quality monitors in distribution systems considering fault location. In 2018 18th international conference on harmonics and quality of power (ICHQP) (pp. 1–6).
Olguin, G., & Bollen, M. H. J. (2003). Optimal dips monitoring program for characterization of transmission system. In Power Engineering Society general meeting, 2003 (Vol. 4, p. 2490). IEEE.
Olguin, G., Vuinovich, F., & Bollen, M. H. J. (2006). An optimal monitoring program for obtaining voltage sag system indexes. IEEE Transactions on Power Systems, 21(1), 378–384.
Santos, W. C., et al. (2010). Automatic building of a simulated high impedance fault database. In Transmission and distribution conference and exposition: Latin America.
Santos, W. C., et al. (2017). High-impedance fault identification on distribution networks. IEEE Transactions on Power Delivery, 32(1), 23–32.
Solano, J. B., Petit-Suárez, J. F., & Ordóñez-Plata, G. (2015). Optimal placement of voltage sag monitors in smart distribution systems: Impact of the dynamic network reconfiguration. In 2015 IEEE PES innovative smart grid technologies Latin America (ISGT LATAM) (pp. 361–365).
Acknowledgements
The authors thank the Brazilian National Research Council (CNPq) and the Brazilian Improvement Coordination of Superior Level Personal (CAPES) for the financial support.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Junqueira, C.M.d.S., Brito, N.S.D., de Souza, B.A. et al. An Algorithm for Optimal Placement of Voltage Sag Monitors. J Control Autom Electr Syst 30, 266–276 (2019). https://doi.org/10.1007/s40313-019-00443-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40313-019-00443-4