Skip to main content
Log in

Effect of delayed centrifugation of whole blood on serum samples stability

  • Articolo originale
  • Published:
La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine

Summary

Background

This study was aimed to investigate the effect of delayed centrifugation of whole blood samples on the quality of serum test results for five conventional clinical chemistry parameters and haemolysis index (HI).

Methods

Five aliquots of whole blood were prepared from each of 22 volunteer subjects. Aliquot 1 was immediately centrifuged and tested, aliquots 2–5 were centrifuged and tested after 3 h, 6 h, 12 h and 24 h of storage of whole blood at room temperature. Results variations of aspartate aminotransferase (AST), lactate dehydrogenase (LDH), potassium (K), total calcium (Ca), inorganic phosporous (iPhos) and haemolysis index (HI) were then compared with values of the baseline aliquot.

Results

After 3 h of storage all parameters except HI and AST exhibited modest but analytically significant variations. After 6 h of storage analytically significant variations were observed for AST, LDH, Ca and iPhos, whereas analytically significant variations were found for LDH, Ca and HI after 12 h of storage. All differences were analytically significant after 24 h of storage of whole blood at room temperature. Values exceeding the acceptable limits were observed for LDH, K and iPhos after 3 h of storage, for AST after 24 h of storage. Calcium remained stable throughout the study period. The HI displayed a considerable increase (i.e., 31.5%) after 24 h of storage.

Conclusions

The results of our experimental study about the impact of delayed centrifugation of whole blood specimens for obtaining serum attest that <3 h at room temperature should be considered the most appropriate time for storing samples before serum analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Lippi G, Guidi GC, Matiuzzi C et al. (2006) Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 44:358–365

    CAS  PubMed  Google Scholar 

  2. Lippi G, Simundic AM (2012) Laboratory networking and sample quality: a still relevant issue for patient safety. Clin Chem Lab Med 50:1703–1705

    CAS  PubMed  Google Scholar 

  3. Lippi G, Banfi G, Buttarello M et al. (2007) Recommendations for detection and management of unsuitable samples in clinical laboratories. Clin Chem Lab Med 45:728–736

    CAS  PubMed  Google Scholar 

  4. Clark S, Youngman LD, Palmer A et al. (2003) Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies. Int J Epidemiol 32:125–130

    Article  PubMed  Google Scholar 

  5. Oddoze C, Lombard E, Portugal H (2012) Stability study of 81 analytes in human whole blood in serum and in plasma. Clin Biochem 45:464–469

    Article  CAS  PubMed  Google Scholar 

  6. Lippi G, Salvagno GL, Blanckaert N et al. (2009) Multicenter evaluation of the hemolysis index in automated clinical chemistry systems. Clin Chem Lab Med 47:934–939

    CAS  PubMed  Google Scholar 

  7. Plebani M, Lippi G (2009) Hemolysis index: quality indicator or criterion for sample rejection? Clin Chem Lab Med 47:899–902

    CAS  PubMed  Google Scholar 

  8. Ricós C, Alvarez V, Cava F et al. (1999) Current database on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 59:491–500

    Article  PubMed  Google Scholar 

  9. Lippi G, Simundic AM (2012) Laboratory networking and sample quality: a still relevant issue for patient safety. Clin Chem Lab Med 50:1703–1705

    CAS  PubMed  Google Scholar 

  10. Lee JE, Hong M, Park SK et al. (2016) Inorganic phosphorous and potassium are putative indicators of delayed separation of whole blood. Osong Public Health Res Perspect 7:90–95

    Article  CAS  PubMed  Google Scholar 

  11. Boyanton BL Jr, Blick KE (2002) Stability studies of twenty-four analytes in human plasma and serum. Clin Chem 48:2242–2247

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Massimo Daves.

Ethics declarations

Conflict of interest

None.

Human and animal rights

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Daves, M., Roccaforte, V., Giacomi, M. et al. Effect of delayed centrifugation of whole blood on serum samples stability. Riv Ital Med Lab 13, 41–44 (2017). https://doi.org/10.1007/s13631-017-0146-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13631-017-0146-x

Keywords

Navigation