Abstract
Radiochromic film has the potential to provide accurate in vivo dosimetry measurements. However, it is not known whether small film pieces can still provide accurate dosimetric results. The use of small film pieces is of particular interest in regions of interest (ROIs) such as the eye, or where the patient’s contour changes rapidly. This study examines the dosimetric accuracy of Gafchromic EBT2 and EBT3 models of radiochromic film and its dependence on film size, ROI size, and height above the scan bed for 6 MV photons and 9 MeV electrons. Films cut to sizes of 5.0 × 5.0, 10.0 × 10.0, 20.0 × 20.0, and 40.0 × 40.0 mm2 were tested and it was found that there was no increase in uncertainty of dose when even the smallest film sizes were used. For a film 5.0 × 5.0 mm2, ROIs of 1.4 × 1.4, 2.1 × 2.1 and 3.5 × 3.5 mm2 were tested and it was found that the ROI size of 2.1 × 2.1 mm2 was the most accurate. The standard deviation of the EBT3 placed on the glass (2.1 %) was larger than the standard deviation of the EBT3 film raised above the glass (1.2 %), therefore it is recommended that film is scanned raised above the scan bed. The general dosimetric performance of EBT3 was comparable to EBT2. We conclude that film pieces as small as 5.0 × 5.0 mm2 could be used for the purpose of in vivo dosimetry of radiotherapy treatments.
References
Kutcher GJ, Coia L, Gillin M, Hanson WF, Leibel S, Morton RJ, Palta JR, Purdy JA, Reinstein LE, Svensson GK, Weller M, Wingfield L (1994) Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys 21(4):581–618
Dutreeix A, Bjarngard BE, Bridier A, Mijnheer B, Shaw JE, Svensson H (1997) Monitor unit calculation for high energy photon beams, first edition. Booklet 3:p121–p124
Devic S, Tomic N, Soares CG, Podgorsak EB (2009) Optimizing the dynamic range extension of a radiochromic film dosimetry system. Med Phys 36(2):429–437
Reinhardt S, Hillbrand M, Wilkens JJ, Assmann W (2012) Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams. Med Phys 39(8):5257–5262
Sutherland JGH, Rogers DWO (2010) Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film. Med Phys 37(3):1110–1117
Arjomandy B, Tailor R, Anand A, Sahoo N, Gillin M, Prado K, Vicic M (2010) Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies. Med Phys 37(5):1942–1947
Lindsay P, Rink A, Ruschin M, Jaffray D (2010) Investigation of energy dependence of EBT and EBT-2 Gafchromic film. Med Phys 37(2):571–576
Butson MJ, Yu PKN, Cheung T, Alnawaf H (2010) Energy response of the new EBT2 radiochromic film to X-ray radiation. Radia Meas 45:836–839
Massillon G, Chiu-Tsao S, Domingo-Munoz I, Chan M (2012) Energy dependence of the new Gafchromic EBT3 film: dose response curves for 50 kV, 6 and 15 MV X-ray beams. Int J Med Phys Clin Eng Radiat Oncol 1(2):60–65
Arjomandy B, Tailor R, Li Z, Devic S (2012) EBT2 film as a depth-dose measurement tool for radiotherapy beams over a wide range of energies and modalities. Med Phys 39(2):912–921
International Specialty Products (2010) Gafchromic EBT2 self-developing film for radiotherapy dosimetry film. http://www.filmqapro.com/Documents/GafChromic_EBT-2_20101007.pdf). Accessed Oct 2012
Borca V, Pasquino M, Russo G, Grosso P, Cante D, Sciacero P, Girelli G, La Porta M, Tofani S (2013) Dosimetric characterisation and use of Gafchromic EBT3 film for IMRT dose verification. Med J Appl Clin Med Phys 14(2):158–171
Nakano M, Hill RF, Whitaker M, Kim J, Kuncic Z (2012) A study of surface dosimetry for breast cancer radiotherapy treatments using Gafchromic EBT2 film. J Appl Clin Med Phys 13(3):83–87
Akino Y, Das IJ, Bartlett GK, Zhang H, Thompson E, Zook JE (2013) Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques. Med Phys 40(1):011714-1–011714-6
Avanzo M, Rink A, Dassie A, Massarut S, Roncadin M, Borsatti E, Capra E (2012) In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast. Med Phys 39(5):2359–2368
Andres C, del Castillo A, Tortosa R, Alonso D, Barquero R (2010) A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT. Med Phys 37(12):6271–6278
Aland T, Kairn T, Kenny J (2011) Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance. Australas Phys Eng Sci Med 34:251–260
Richley L, John AC, Coomber H, Fletcher S (2010) Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy. Phys Med Biol 55:2601–2617
Lynch BD, Kozelka J, Ranade MK, Li JG, Simon WE, Dempsey JF (2006) Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film. Med Phys 33(12):4551–4556
Paelinck L, De Neve W, De Wagter C (2007) Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry. Phys Med Biol 52:231–242
Schneider F, Polednik M, Wolff D, Stell V, Delana A, Wenz F, Menegotti L (2008) Optimisation of the Gafchromic EBT protocol for IMRT QA. Z Med Phys 19:29–37
Kairn T, Aland T, Kenny J (2010) Local heterogeneities in early batches of EBT2 film: a suggested solution. Phys Med Biol 55:L37–L42
Lewis DF (2011) A practical guide to radiochromic film EBT2/EBT3. http://www.filmqapro.com/Documents/Lewis%20-%20Europe%2011-2011.pdf. Accessed October 2012
Johnson RA, Bhattacharyya GK (2006) Statistics: principles and methods. Wiley, New York
Hartmann B, Martišíková M, Jäkel O (2010) Technical note: Homogeneity of Gafchromic EBT2 film. Med Phys 37(4):1753–1756
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Moylan, R., Aland, T. & Kairn, T. Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry. Australas Phys Eng Sci Med 36, 331–337 (2013). https://doi.org/10.1007/s13246-013-0206-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13246-013-0206-0