Early failure of quadricuspid aortic valve tricuspidization due to dehiscence of approximating coronary cusps

  • Case Report
  • Published:
Journal of Echocardiography Aims and scope Submit manuscript

Abstract

A 48-year-old woman diagnosed with aortic regurgitation showing a quadricuspid aortic valve (QAV) underwent repair with tricuspidization. Two non-coronary cusps (NCC) with fenestrations were detected intraoperatively. Tricuspidization of QAV was performed by approximating the two NCCs via interrupted sutures. The aortic annulus was plicated by subcommissural annuloplasty. The residual aortic regurgitation was mild, with a vena contracta of 2.1 mm. On postoperative day 5, echocardiography demonstrated a new regurgitation from the middle of the neo-NCC, and increased central regurgitation. Intraoperative findings showed the dehiscence of approximating sutures of the neo-NCC. Mechanical valve replacement was performed uneventfully.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Feldman BJ, Khandheria BK, Warnes CA, et al. Incidence, description, and functional assessment of isolated quadricuspid aortic valve. Am J Cardiol. 1990;65:937–8.

    Article  CAS  PubMed  Google Scholar 

  2. Jagannath AD, Johri AM, Liberthson R, et al. Quadricuspid aortic valve: a report of 12 cases and a review of the literature. Echocardiography. 2011;28:1035–40.

    Article  PubMed  Google Scholar 

  3. Schmidt KI, Jeserich M, Aicher D, et al. Tricuspidization of the quadricuspid aortic valve. Ann Thorac Surg. 2008;85:1087–9.

    Article  PubMed  Google Scholar 

  4. Luciani GB, Morjan M, Faggian G, et al. Repair of quadricuspid aortic valve by bicuspidzation: a novel technique. Interract Cardiovasc Thorac Surg. 2010;11:348–50.

    Article  Google Scholar 

  5. Departi A, Generali T, Arlati F, et al. Quadricuspid aortic valve plasty: is it worth it to repair as an alternative to substitution? Ann Thorac Surg. 2013;95:e7–8.

    Article  Google Scholar 

  6. Katayama H, Shimamoto T, Maruo T, et al. Significance of effective-height caliper for the repair of quadricuspid aortic valve. Eur J Caridothorac Surg. 2011;40:1273.

    Google Scholar 

Download references

Conflict of interest

The authors have declared that no conflict of interest exists.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Suguru Ohira.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ohira, S., Doi, K., Yamano, T. et al. Early failure of quadricuspid aortic valve tricuspidization due to dehiscence of approximating coronary cusps. J Echocardiogr 12, 75–77 (2014). https://doi.org/10.1007/s12574-014-0214-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12574-014-0214-4

Keywords

Navigation