Sources of variability in the measurement of perfusion defect size using commercially available software programs: Are there gender differences?

  • Brief Report
  • Published:
Journal of Nuclear Cardiology Aims and scope

Abstract

We recently showed that Quantitative Perfusion SPECT (QPS), Emory Cardiac Toolbox (ECTb) and 4-Dimension-Myocardial SPECT (4DM) yielded discordant results in the assessment of perfusion defect size (PDS) in patients with known or suspected coronary artery disease. In this report, we examined the sources of variability in the measurement of PDS using ECTb (VarECTb), 4DM (Var4DM) and QPS (VarQPS) and found that gender is a source of variability in the assessment of PDS. In 120 patients, VarECTb was lower in men, compared with women, whereas Var4DM and VarQPS were similar between both genders. Among men, VarECTb was lowest, compared with VarQPS and Var4DM, whereas, VarECTb, VarQPS, and Var4DM were not different among women. Future studies should account for gender differences when comparing the 3 software programs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1

References

  1. Ather S, Iqbal F, Gulotta J, Aljaroudi W, Heo J, Iskandrian AE, Hage FG. Comparison of three commercially available softwares for measuring left ventricular perfusion and function by gated SPECT myocardial perfusion imaging. J Nucl Cardiol 2014;21:673–81.

    Article  PubMed  Google Scholar 

  2. Wackers FJT. Call for a standard unit of defect size. J Nucl Cardiol 2014;21:682–4.

    Article  PubMed  Google Scholar 

  3. Wolak A, Slomka PJ, Fish MB, Lorenzo S, Acampa W, Berman DS, Germano G. Quantitative myocardial-perfusion SPECT: Comparison of three state-of-the-art software packages. J Nucl Cardiol 2008;15:27–34.

    Article  PubMed  Google Scholar 

Download references

Disclosure

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sameer Ather MD, PhD, FACC.

Additional information

Funding

SA is supported by intramural Frommeyer Fellowship in Investigative Medicine.

All editorial decisions for this article, including selection of reviewers and the final decision, were made by guest editor Alberto Cuocolo, MD.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ather, S., Iskandrian, A.E. & Hage, F.G. Sources of variability in the measurement of perfusion defect size using commercially available software programs: Are there gender differences?. J. Nucl. Cardiol. 24, 1089–1093 (2017). https://doi.org/10.1007/s12350-016-0679-9

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12350-016-0679-9

Keywords

Navigation