Skip to main content
Log in

Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera

  • Original Article
  • Published:
Journal of Nuclear Cardiology Aims and scope

Abstract

Background

New multipinhole cadmium-zinc-telluride (CZT) cameras allow for faster imaging and lower radiation doses for single photon emission computed tomography (SPECT) studies, but assessment of prognostic ability is necessary.

Methods and Results

We collected data from all myocardial SPECT perfusion studies performed over 15 months at our institution, using either a CZT or conventional Anger camera. A Cox proportional hazards model was used to assess the relationship between camera type, imaging results, and either death or myocardial infarction (MI). Clinical variables including age, sex, body mass index (BMI), and historical risk factors were used for population description and model adjustments. We had 2,088 patients with a total of 69 deaths and 65 MIs (122 events altogether). A 3% increase in DDB (difference defect burden) represented a 12% increase in the risk of death or MI, whereas a 3% increase in rest defect burden or stress defect burden represented an 8% increase; these risks were the same for both cameras (P > .24, interaction tests).

Conclusions

The CZT camera has similar prognostic values for death and MI to conventional Anger cameras. This suggests that it may successfully be used to decrease patient dose.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2

Similar content being viewed by others

Abbreviations

MI:

Myocardial infarction

CAD:

Coronary artery disease

SSS:

Summed stress score

SDS:

Summed difference score

SRS:

Summed rest score

SDB:

Stress defect burden

RDB:

Rest defect burden

DDB:

Difference defect burden

References

  1. Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 1979;300:1350-8.

    Article  CAS  PubMed  Google Scholar 

  2. Mark DB, Shaw LK, Harrell FE Jr, Hlatky MA, Lee KL, Bengtson JR, et al. Prognostic value of a treadmill exercise score in outpatients with suspected coronary artery disease. N Engl J Med 1991;325:849-53.

    Article  CAS  PubMed  Google Scholar 

  3. Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico JA, Friedman J, et al. Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and impact on subsequent patient management. Circulation 1996;93:905-14.

    Article  CAS  PubMed  Google Scholar 

  4. Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.

    Article  CAS  PubMed  Google Scholar 

  5. Pryor DB, Shaw L, McCants CB, Lee KL, Mark DB, Harrell FE Jr, et al. Value of the history and physical in identifying patients at increased risk for coronary artery disease. Ann Intern Med 1993;118:81-90.

    Article  CAS  PubMed  Google Scholar 

  6. Ottenhof MJ, Wai MC, Boiten HJ, Korbee RS, Valkema R, van Domburg RT, et al. 12-Year outcome after normal myocardial perfusion SPECT in patients with known coronary artery disease. J Nucl Cardiol 2013;20:748-54.

    Article  PubMed  Google Scholar 

  7. Schepis T, Benz K, Haldemann A, Kaufmann PA, Schmidhausen C, Frielingsdorf J. Prognostic value of stress-gated 99 m-technetium SPECT myocardial perfusion imaging: Risk stratification of patients with multivessel coronary artery disease and prior coronary revascularization. J Nucl Cardiol 2013;20:755-62.

    Article  PubMed  Google Scholar 

  8. Fihn SD, Gardin JM, Abrams J, Berra K, Blankenship JC, Dallas AP, et al. 2012 ACCF/AHA/ACOP/AATS/PCNA/SCAI/STS guideline for the diagnosis and management of patients with stable ischemic heart disease. Circulation 2012;126:3097-137.

    Article  PubMed  Google Scholar 

  9. Goske MJ, Applegate KE, Boylan J, Butler PF, Callahan MJ, Boley BD, et al. The ‘Image Gently’ campaign: Increasing CT radiation dose awareness through a national education and awareness program. Pediatr Radiol 2008;38:265-9.

    Article  PubMed  Google Scholar 

  10. Brink JA, Amis ES Jr. Image Wisely: A campaign to increase awareness about adult radiation protection. Radiology 2010;257:601-2.

    Article  PubMed  Google Scholar 

  11. Jafari ME, Daus AM. Applying Image Gently and Image Wisely in nuclear medicine. Health Phys 2013;104:S31-6.

    Article  CAS  PubMed  Google Scholar 

  12. GE Healthcare. Alcyone technology: white paper 2009. Document ID NU-0173-02.09-EN-US. New York: General Electric Company.

  13. Oddstig J, Hedeer F, Jogi J, Carlsson M, Hindorf C, Engblom H. Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera. J Nucl Cardiol 2013;20:38-44.

    Article  PubMed  Google Scholar 

  14. Duvall WL, Sweeny JM, Croft LB, Ginsberg E, Guma KA, Henzlova MJ. Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: Comparison to coronary angiography. J Nucl Cardiol 2012;19:19-27.

    Article  PubMed  Google Scholar 

  15. Mouden M, Timmer JR, Ottervanger JP, Reiffers S, Oostdijk AH, Knollema S, et al. Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: Fewer equivocal results and lower radiation dose. Eur J Nucl Med Mol Imaging 2012;39:1048-55.

    Article  PubMed  Google Scholar 

  16. Verger A, Djaballah W, Fourquet N, Rouzet F, Koehl G, Imbert L, et al. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols. Eur J Nucl Med Mol Imaging 2013;40:331-40.

    Article  CAS  PubMed  Google Scholar 

  17. Tanaka H, Chikamori T, Hida S, Uchida K, Igarashi Y, Yokoyama T, et al. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera. Circ J 2013;77:1009-17.

    Article  CAS  PubMed  Google Scholar 

  18. Duvall WL, Slomka PJ, Gerlach JR, Sweeny JM, Baber U, Croft LB, et al. High-efficiency SPECT MPI: Comparison of automated quantification, visual interpretation, and coronary angiography. J Nucl Cardiol 2013;20:763-73.

    Article  PubMed  Google Scholar 

  19. Nakazato R, Berman DS, Gransar H, Hyun M, Miranda-Peats R, Kite FC, et al. Prognostic value of quantitative high-speed myocardial perfusion imaging. J Nucl Cardiol 2012;19:1113-23.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Salerno M, Elliot L, Shaw LK, Piccini JP, Pagnanelli R, Borges-Neto S. Prognostic validation of an algorithm to convert myocardial perfusion SPECT imaging data from a 12-segment model to a 17-segment model. J Nucl Cardiol 2009;16:605-13.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Salustri A, Pozzoli MMA, Hermans W, Ilmer B, Cornel JH, Reijs AEM, et al. Relationship between exercise echocardiography and perfusion single-photon emission computed tomography in patients with single-vessel coronary artery disease. Am Heart J 1992;124:75-83.

    Article  CAS  PubMed  Google Scholar 

  22. Harris PJ, Harrel FE Jr, Lee KL, Behar VS, Rosati RA. Survival in medically treated patients with coronary artery disease. Circulation 1979;60:1259-69.

    Article  CAS  PubMed  Google Scholar 

  23. Rosati RA, McNeer JF, Starmer CF, Mittler BS, Morris JJ Jr, Wallace AG. A new information system for medical practice. Arch Intern Med 1975;135:1017-24.

    Article  CAS  PubMed  Google Scholar 

  24. Stone CJ, Koo CY. Additive splines in statistics. Proc Stat Comp Sect Am Statist Assoc 1985;27:45-8.

    Google Scholar 

  25. Visscher TL, Seidell JC, Molarius A, van der Kuip D, Hofman A, Witteman JC. A comparison of body mass index, waist-hip ratio and waist circumference as predictors of all-cause mortality among the elderly: The Rotterdam study. Int J Obesity Relat Metab Disord 2001;25:1730-5.

    Article  CAS  Google Scholar 

  26. Allison DB, Zannolli R, Faith MS, Heo M, Pietrobelli A, Vanltallie TB, et al. Weight loss increases and fat loss decreases all-cause mortality rate: Results from two independent cohort studies. Int J Obesity Relat Metab Disord 1999;23:603-11.

    Article  CAS  Google Scholar 

Download references

Disclosures

Jorge Oldan, Paul Hofmann, Linda K. Shaw, Matthew Phelan, and Salvador Borges-Neto have no conflicts of interest. Jorge Oldan and Salvador Borges-Neto are affiliated with Duke University Medical Center. Paul Hofmann, Linda K. Shaw, and Matthew Phelan are associated with the Duke Clinical Research Institute.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jorge Daniel Oldan MD.

Additional information

See related editorial, doi:10.1007/s12350-015-0224-2.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oldan, J.D., Shaw, L.K., Hofmann, P. et al. Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera. J. Nucl. Cardiol. 23, 1280–1287 (2016). https://doi.org/10.1007/s12350-015-0181-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12350-015-0181-9

Keywords

Navigation