Skip to main content
Log in

Does the Use of Intraoperative Microelectrode Recording Influence the Final Location of Lead Implants in the Ventral Intermediate Nucleus for Deep Brain Stimulation?

  • Original Paper
  • Published:
The Cerebellum Aims and scope Submit manuscript

Abstract

To determine if the use of intraoperative microelectrode recording (MER) influences the final location of lead implant in deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM), and to evaluate the incidence of associated complications. The usefulness of intraoperative MER in DBS is debated, some centers suggesting it increases complications without additional benefit. We conducted a retrospective chart review of all patients who underwent VIM DBS with MER at the University of Texas Health Science Center in Houston from June 1, 2009 to October 1, 2013. Initial (MRI determined) and final (intraoperative MER determined) coordinates of implant were compared. To assess incidences of hemorrhagic and infectious complications, we reviewed postoperative CT scans and follow-up notes. Forty-five lead implants on 24 patients were reviewed. The mean age at implantation was 62.42 years (range 18–83). The average duration from diagnosis to surgery was 21.5 years (range 1–52). A statistically significant mean difference was observed in the superior-inferior plane (0.52 ± 0.80 mm inferiorly, p < 0.05) and the anterior-posterior plane (0.45 ± 0.86 mm posteriorly, p < 0.05). A non-statistically significant difference was also observed in the medial-lateral plane (0.02± 0.15 mm, p > 0.05). One patient developed an infectious complication (4.2 %) that required removal of leads; two patients had minimal asymptomatic intra-ventricular bleeding (8.3 %). In our DBS center, intraoperative MER in VIM DBS implant does not seem to have a higher rate of surgical complications compared to historical series not using MER, and might also be useful in determining the final lead location.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Chopra A, Klassen BT, Stead M. Current clinical application of deep-brain stimulation for essential tremor. Neuropsychiatr Dis Treat. 2013;9:1859–65.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Lyons KE, Pahwa R. Deep brain stimulation and essential tremor. J Clin Neurophysiol Off Publ Am Electroencephalograph Soc. 2004;21(1):2–5.

    Google Scholar 

  3. Borretzen MN, Bjerknes S, Saehle T, Skjelland M, Skogseid IM, Toft M, et al. Long-term follow-up of thalamic deep brain stimulation for essential tremor—patient satisfaction and mortality. BMC Neurol. 2014;14:120.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Zhang K, Bhatia S, MY O, Cohen D, Angle C, Whiting D. Long-term results of thalamic deep brain stimulation for essential tremor. J Neurosurg. 2010;112(6):1271.

    Article  PubMed  Google Scholar 

  5. Villareal S, Fenoy A. Deep brain stimulation for the neurosurgical standpoint. In: Mehanna R, editor. Deep brain stimulation. New York: Nova Science Publishers; 2015.

    Google Scholar 

  6. Montgomery Jr EB. Microelectrode targeting of the subthalamic nucleus for deep brain stimulation surgery. Mov Disord Off J Mov Disord Soc. 2012;27(11):1387–91.

    Article  Google Scholar 

  7. Chen SY, Lee CC, Lin SH, Hsin YL, Lee TW, Yen PS, et al. Microelectrode recording can be a good adjunct in magnetic resonance image-directed subthalamic nucleus deep brain stimulation for parkinsonism. Surg Neurol. 2006;65(3):253–60 .discussion 60-1

    Article  PubMed  Google Scholar 

  8. Hamani C, Richter EO, Andrade-Souza Y, Hutchison W, Saint-Cyr JA, Lozano AM. Correspondence of microelectrode mapping with magnetic resonance imaging for subthalamic nucleus procedures. Surg Neurol 2005;63(3):249–53; discussion 253.

  9. Groiss SJ, Wojtecki L, Sudmeyer M, Schnitzler A. Deep brain stimulation in Parkinson’s disease. Ther Adv Neurol Disord. 2009;2(6):20.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  10. Burchiel KJ, McCartney S, Lee A, Raslan AM. Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording. J Neurosurg. 2013;119(2):301–6.

    Article  PubMed  Google Scholar 

  11. Khatib R, Ebrahim Z, Rezai A, Cata JP, Boulis NM, John Doyle D, et al. Perioperative events during deep brain stimulation: the experience at Cleveland clinic. J Neurosurg Anesthesiol. 2008;20(1):36–40.

    Article  PubMed  Google Scholar 

  12. Reck C, Maarouf M, Wojtecki L, Groiss SJ, Florin E, Sturm V, et al. Clinical outcome of subthalamic stimulation in Parkinson’s disease is improved by intraoperative multiple trajectories microelectrode recording. J Neurol Surg A Cen Eur Neurosurg. 2012;73(6):377–86.

    Article  Google Scholar 

  13. Machado A, Rezai AR, Kopell BH, Gross RE, Sharan AD, Benabid AL. Deep brain stimulation for Parkinson’s disease: surgical technique and perioperative management. Mov Disord Off J Mov Disord Soc. 2006;21 Suppl 14:S247–S258.

  14. Anthofer J, Steib K, Fellner C, Lange M, Brawanski A, Schlaier J. The variability of atlas-based targets in relation to surrounding major fibre tracts in thalamic deep brain stimulation. Acta Neurochir. 2014;156(8):1497–504 .discussion 504

    Article  PubMed  Google Scholar 

  15. Bardinet E, Belaid H, Grabli D, Welter ML, Vidal SF, Galanaud D, et al. Thalamic stimulation for tremor: can target determination be improved? Mov Disord Off J Mov Disord Soc. 2011;26(2):307–12.

    Article  Google Scholar 

  16. Schlaier J, Anthofer J, Steib K, Fellner C, Rothenfusser E, Brawanski A, et al. Deep brain stimulation for essential tremor: targeting the dentato-rubro-thalamic tract? Neuromodul J Int Neuromodul Soc. 2015;18(2):105–12.

    Article  Google Scholar 

  17. Coenen VA, Allert N, Madler B. A role of diffusion tensor imaging fiber tracking in deep brain stimulation surgery: DBS of the dentato-rubro-thalamic tract (drt) for the treatment of therapy-refractory tremor. Acta Neurochir. 2011;153(8):1579–85 .discussion 85

    Article  PubMed  Google Scholar 

  18. Vitek JL, Bakay RA, Hashimoto T, Kaneoke Y, Mewes K, Zhang JY, et al. Microelectrode-guided pallidotomy: technical approach and its application in medically intractable Parkinson’s disease. J Neurosurg. 1998;88(6):1027–43.

    Article  CAS  PubMed  Google Scholar 

  19. Guridi J, Gorospe A, Ramos E, Linazasoro G, Rodriguez MC, Obeso JA. Stereotactic targeting of the globus pallidus internus in Parkinson’s disease: imaging versus electrophysiological mapping. Neurosurgery. 1999;45(2):278–87 .discussion 87-9

    Article  CAS  PubMed  Google Scholar 

  20. Senatus PB, Teeple D, McClelland III S, Pullman SL, Yu Q, Ford B, et al. A technique for minimally altering anatomically based subthalamic electrode targeting by microelectrode recording. Neurosurg Focus. 2006;20(5):E8.

    Article  PubMed  Google Scholar 

  21. Hariz MI, Fodstad H. Do microelectrode techniques increase accuracy or decrease risks in pallidotomy and deep brain stimulation? A critical review of the literature. Stereotact Funct Neurosurg. 1999;72(2–4):157–69.

    CAS  PubMed  Google Scholar 

  22. Binder DK, Rau GM, Starr PA. Risk factors for hemorrhage during microelectrode-guided deep brain stimulator implantation for movement disorders. Neurosurgery. 2005;56(4):722–32 .discussion -32

    Article  PubMed  Google Scholar 

  23. Maldonado IL, Roujeau T, Cif L, Gonzalez V, El-Fertit H, Vasques X, et al. Magnetic resonance-based deep brain stimulation technique: a series of 478 consecutive implanted electrodes with no perioperative intracerebral hemorrhage. Neurosurgery 2009;65(6 Suppl):196–201; discussion -2.

  24. Koller WC, Lyons KE, Wilkinson SB, Troster AI, Pahwa R. Long-term safety and efficacy of unilateral deep brain stimulation of the thalamus in essential tremor. Mov Disord Off J Mov Disord Soc. 2001;16(3):464–8.

    Article  CAS  Google Scholar 

  25. Blomstedt P, Hariz MI. Are complications less common in deep brain stimulation than in ablative procedures for movement disorders? Stereotact Funct Neurosurg. 2006;84(2–3):72–81.

    Article  PubMed  Google Scholar 

  26. Patel DM, Walker HC, Brooks R, Omar N, Ditty B, Guthrie BL. Adverse events associated with deep brain stimulation for movement disorders: analysis of 510 consecutive cases. Neurosurgery 2015;11 Suppl 2:190–199.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Raja Mehanna.

Ethics declarations

Disclosures

Disclosure related to the manuscript: the authors have no disclosures. Disclosures over the last 12 months, not related to manuscript: S. Reddy has nothing to disclose, A. Fenoy has nothing to disclose, E. Furr-Stimming is on the speakers bureau for Lundbeck and Impax, M. Schiess has nothing to disclose, and R. Mehanna received consultation fees from Merz Pharma.

Conflict of Interest

Authors do not have any potential conflicts of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Reddy, S., Fenoy, A., Furr-Stimming, E. et al. Does the Use of Intraoperative Microelectrode Recording Influence the Final Location of Lead Implants in the Ventral Intermediate Nucleus for Deep Brain Stimulation?. Cerebellum 16, 421–426 (2017). https://doi.org/10.1007/s12311-016-0816-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12311-016-0816-7

Keywords

Navigation