Skip to main content
Log in

The impact of air filter pressure drop on the performance of typical air-conditioning systems

  • Research Article
  • Building Systems and Components
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Filters are used in heating, ventilation, and air-conditioning (HVAC) systems for both commercial and residential buildings to protect the equipment and improve indoor air quality in conditioned spaces. Although there are many benefits of using the air filter in an air-conditioning system, the resistance associated with it can increase fan energy use and may adversely affect air-conditioning system performance and efficiency. The paper explores the impact of air filtration on energy consumption for a typical air-conditioning (AC) system with constant- or variable-speed fan. A whole building simulation model is used to simulate the annual energy consumption for various air-conditioning system capacities, different levels of filter cleanliness, and various filter minimum efficiency reporting values (MERV). The results indicate that with a constant-speed fan, the cooling energy use increases as the filter gets dirty over time and the energy use in the fan may increase but this depends heavily on the investigated fan performance curve. With a variable-speed fan, the fan energy use increases with a dirty filter but the cooling and heating energy uses are slightly affected. The fan energy use rise due to the dirty filter depends mainly on air system capacities, filter MERV ratings, and the degree of the filter cleanliness.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • ANSI/ASHRAE (2007). ANSI/ASHRAE Standard 52.2. Method of testing general ventilation air-cleaning devices for removal efficiency by particle size. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2008). ASHRAE Handbook-HVAC Systems and Equipment, Chapters 9 and 28. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Brandemuehl MJ, Gabel S, Andersen I (1993). A Toolkit for Secondary HVAC System Energy Calculation. Atlanta, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • James P, Cummings J, Sonne J, Vieira R, Klongerbo J (1997). The effect of residential equipment capacity on energy use, demand, and run-time. ASHRAE Transactions, 103(2): 297–303.

    Google Scholar 

  • Nassif N (2012). Impacts of air filters on energy consumption in typical HVAC systems. Paper presented at the 2012 Annual ASHRAE Meeting, San Antonio, USA.

  • Palani M, O’Neal D, Haberl J (1992). The effect of reduced evaporator air flow on the performance of a residential central air-conditioner. In: Proceedings of the 8th Annual Symposium on Improving Building Energy Efficiency in Hot and Humid Climates, Dallas, USA.

  • Parker D, Sherwin J, Raustad R, Shirey III D (1997). Impact of evaporator coil airflow in residential air-conditioning systems. ASHRAE Transactions, 103(2): 395–405.

    Google Scholar 

  • Siegel JA, Nazaroff WW (2003). Predicting particle deposition on HVAC heat exchangers. Atmospheric Environment, 37: 5587–5596.

    Article  Google Scholar 

  • Stephens B, Novoselac A, Siegel AJ (2009). Impacts of HVAC Filtration on air-conditioner energy consumption in residences. In: Proceedings of Healthy Buildings 2009 (paper 474), Syracuse, USA.

  • Yang L, Braun JE, Groll WA (2007a). The impact of evaporator fouling and filtration on the performance of packaged air-conditioners. International Journal of Refrigeration, 30: 506–514.

    Article  Google Scholar 

  • Yang L, Braun JE, Groll WA (2007b). The impact of fouling on the performance of filter-evaporator combinations. International Journal of Refrigeration, 30: 489–498.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nabil Nassif.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nassif, N. The impact of air filter pressure drop on the performance of typical air-conditioning systems. Build. Simul. 5, 345–350 (2012). https://doi.org/10.1007/s12273-012-0091-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-012-0091-6

Keywords

Navigation