Abstract
One of the main breakthroughs in the concrete technology in the 20th century was the development of Ultra-High Performance Fiber Reinforced Concrete (UHPFRC) as a new generation of sustainable construction material. This paper is presented in two parts. The analysis and design procedures as well as the Environmental Impact Calculations (EIC) of the precast UHPFRC cantilever retaining walls as a sustainable alternative approach to conventional precast Reinforced Concrete (RC) cantilever retaining walls were presented in the first part (Part I) of this paper. In this part (Part II), the reliability of the precast UHPFRC cantilever retaining walls were evaluated through full scale experimental testing. In the experimental tests, four full-scale UHPFRC wall specimens with the dimensions of 2.5 m in height, 2 m in length, and 2 m in width were cast. The area of the steel bars used in the wall stem of the specimens, and the volumetric ratio of the steel fibers used in the UHPFRC mix design were the test parameters. The experimental results proved that the precast cantilever retaining walls manufactured from UHPFRC as a sustainable alternative solution has superior properties in all aspects compared to the conventional precast RC cantilever retaining wall.
Similar content being viewed by others
References
ASTM C230M (2008). Standard specification for flow table for use in tests of hydraulic cement, American Society for Testing and Materials (ASTM) Standards United States.
ASTM C1018 (1997). Standard test method for flexural toughness and first crack strength of fiber reinforced concrete (using beam with third point loading), American Society for Testing and Materials (ASTM) Standards United States.
BS 6319-2 (1983). Testing of resin and polymer/cement compositions for use in construction, Method form measurement of compressive strength British Standard, UK.
BS EN 1992-1-1 (2004). Eurocode 2: Design of concrete structures-Part 1-1: General rules and rules for buildings, British Standard, UK.
BS EN 1997-1 (2004). Eurocode 7: Geotechnical design- Part 1: General rules, British Standards, UK.
BS EN 15258 (2008). Precast concrete products-Retaining wall elements, British Standards, UK.
JSCE (2006). Recommendations for design and construction of ultra high strength fiber reinforced concrete structures (Draft), JSCE Guideline for Concrete No. 9, Concrete Committee of Japan Society of Civil Engineers (JSCE) Japan.
Mosley, W. H., Bungey, J. H., and Hulse, R. (2007). Reinforced concrete design to Eurocode 2, Palgrave MacMillan.
MS 522-Part 2 (1989). Specification for Portland cement, Part 2: Determination of soundness, Standards and Industrial Research Institute of Malaysia (SIRIM) Kuala Lumpur.
Voo, Y. L. and Foster, S. J. (2003). Variable engagement model for fibre reinforced concrete in tension, UNICIV Report No. R-420, School of Civil and Environmental Engineering, The University of New South Wales Australia.
Voo, Y. L. and Foster, S. J. (2010). “Characteristics of ultra-high performance ‘ductile’ concrete and its impact on sustainable construction.” The IES Journal Part A: Civil & Structural Engineering, Vol. 3, No. 3, pp. 168–187.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nematollahi, B., Voo, Y.L. & Saifulnaz M. R, R. Structural behavior of precast Ultra-High Performance Fiber Reinforced Concrete (UHPFRC) cantilever retaining walls: Part II — Full scale experimental testing. KSCE J Civ Eng 18, 1481–1495 (2014). https://doi.org/10.1007/s12205-014-0412-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-014-0412-7