Abstract
A large number of Reinforced Concrete (RC) buildings are constructed with masonry infill for functional or aesthetic reasons. Sometimes window or ventilator openings have been left in the wall for architectural necessities. RC constructions with such partial masonry infill face serious earthquake shear damages in columns due to captive-column effect. The purpose of this research is to investigate the behavior of non-ductile RC frames with partial masonry infill under lateral loading and to reduce the potential for captive-column damage induced by partial infill. An experimental study is carried out with one-third scale, two-bay two-story laboratory models having partial infill in the bottom story. A local retrofitting strategy of strengthening RC structural elements with Glass-Fiber Reinforced Polymer (GFRP) composites is adopted. Two frames namely, a control specimen and a retrofitted specimen are tested under quasi-static cyclic load to failure. The control specimen showed a brittle shear failure in bottom story columns due to the induced captive-column effect while the retrofitted specimen exhibited an improved performance. Results demonstrated the behavior with respect to strength, stiffness and ductility characteristics. The aim is, therefore to contribute for developing a sustainable structure to overcome the seismic failure due to captive-column defects.
Similar content being viewed by others
References
Achyutha, H., Jagadish, R., Rao, P. S., and Rahman, S. S. (1986). “Finite element simulation of the elastic behavior of infilled frames with openings.” Computers and Structures, Vol. 23, No. 5, pp. 685–696.
Asteris, P. G. (2003). “Lateral stiffness of brick masonry infilled plane frames.” Journal of Structural Engineering, ASCE, Vol. 129, No. 8, pp. 1071–1079.
Balasubramanian, K., Krishnamoorthy, T. S., Bharatkumar, B. H., Udhayakumar, V., and Lakshmanan, N. (2007). “Investigations on the RC structural elements retrofitted using FRP wraps.” Journal of Structural Engineering, Vol. 34, No. 1, pp. 63–69.
Balsamo, A., Colombo, A., Manfredi, G., Negro, P., and Prota, A. (2005). “Seismic behavior of a full-scale RC frame repaired using CFRP laminates.” Engineering Structures, Vol. 27, No. 5, pp. 769–780.
Cagatay, I. H. (2005). “Failure of an Industrial building during a recent earthquake in Turkey.” Engineering Failure Analysis, Vol. 12, No. 4, pp. 497–507.
Chiew, S-P., Sun, Q., and Yu, Y. (2007). “Flexural strength of RC beams with GFRP laminates.” Journal of Composites for Construction, ASCE, Vol. 11, No. 5, pp. 497–506.
Chiou, Y., Tzeng, J., and Liou, Y. (1999). “Experimental and analytical study of masonry infilled frames.” Journal of Structural Engineering, ASCE, Vol. 125, No. 10, pp. 1109–1117.
Chung, Y. S., Lee, D. H., Park, C. K., and Park, J. Y. (2002). “Seismic enhancement of circular RC bridge piers with fiber composites.” KSCE Journal of Civil Engineering, Vol. 6, No. 4, pp. 485–493.
Ferrier, E., Avril, S., Hamelin, P., and Vautrin, A. (2003). “Mechanical behavior of RC beams reinforced by externally bonded CFRP sheets.” Materials and Structures, Vol. 36, No. 8, pp. 522–529.
Galal, K., Arafa, A., and Ghobarah, A. (2005). “Retrofit of RC square short columns.” Engineering Structures, Vol. 27, No. 5, pp. 801–813.
Ghobarah, A. and Said, A. (2002). “Shear strengthening of beamcolumn joints.” Engineering Structures, Vol. 24, No. 7, pp. 881–888.
Guevara, L. T. and Garcia, L. E. (2005). “The captive- and short-column effects.” Earthquake Spectra, Vol. 21, No. 1, pp. 141–160.
Kumutha, R., Vaidyanathan, R., and Palanichamy, M. S. (2007). “Behaviour of reinforced concrete rectangular columns strengthened using GFRP.” Cement and Concrete Composites, Vol. 29, No. 8, pp. 609–615.
Ludovico, D. M., Manfredi, G., Mola, E., Negro, P., and Prota, A. (2008). “Seismic behavior of a full-scale RC structure retrofitted using GFRP laminates.” Journal of Structural Engineering, ASCE, Vol. 134, No. 5, pp. 810–821.
Pan, J. L., Xu, T., and Hu, Z.J. (2007). “Experimental investigation of load carrying capacity of the slender reinforced concrete columns wrapped with FRP.” Construction and Building Materials, Vol. 21, No. 11, pp. 1991–1996.
Paulay, T. and Priestley, M. J. N. (1992). Seismic design of reinforced concrete and masonry buildings, John Wiley and Sons, Inc., USA.
Prota, A., Manfredi, G., and Cosenza, E. (2006). “Ultimate behavior of axially loaded RC wall-like columns confined with GFRP.” Composites Part B: Engineering, Vol. 37, No. 7–8, pp. 670–678.
Reddy, P. B., Alagusundaramoorthy, P., and Sundaravadivelu, R. (2009). “Retrofitting of RC piles using GFRP composites.” KSCE Journal of Civil Engineering, Vol. 13, No. 1, pp. 39–47.
Rocha, P., Delgado, P., Costa, A., and Delgado, R. (2004). “Seismic retrofit of RC frames.” Computers and Structures, Vol. 82, No. 17–19, pp. 1523–1534.
Sheikh, S. A. (2002). “Performance of concrete structures retrofitted with fibre reinforced polymers.” Engineering Structures, Vol. 24, No. 7, pp. 869–879.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jayaguru, C., Subramanian, K. Retrofit of RC frames with captive-column defects. KSCE J Civ Eng 16, 1202–1208 (2012). https://doi.org/10.1007/s12205-012-1019-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12205-012-1019-5