Introduction

Nowadays, countries all over the world face the problem of environmental pollution (Gallo and Almirall 2009; Ozden 2010). Many ecological and environmental changes emerge as a result of human agricultural and industrial activity (Pohl et al. 2009; Szyczewski et al. 2009). Significant emphasis is placed on a wide range of chemical pollutants including heavy metals (Orecchio and Amorello 2010; Akinci et al. 2013; Struis et al. 2013). Aquatic pollution caused by heavy metals is particularly important due to their toxicity and accumulation capacity in organisms (Mendil et al. 2009; Shah et al. 2009). High levels of copper, lead and iron have been found to cause physiological changes in fish (Tarrio et al. 1991). On the other hand, fish are an important part of a balanced human diet as they contain a lot of proteins, vitamins, minerals and polyunsaturated fatty acids (Shrestha et al. 2013; Gogus and Smith 2010). Thus, the Nutrition Committee of the American Heart Association recommends eating fish at least twice a week to prevent cardiovascular diseases (Kris-Etherton et al. 2002). Rainbow trout (Oncorhynchus mykiss, in the family Salmonidae) are widely used as a farmed fish in many countries around the world due to its high nutritional value and rapid growth (Gall and Crandell 1992; Mashaie 2001). Nevertheless, fish can be a source of contaminants, such as highly toxic heavy metals. Hence, the determination of metals in fish is indeed indispensable and has drawn much attention in recent years (Sneddon et al. 2007; Sneddon and Vincent 2008; Zmozinski et al. 2013; Rofouei et al. 2012). Analysis of heavy metals in the various tissues of fish has been widely pursued using different methods, including electrochemistry (Bagheri et al. 2013), atomic absorption spectrophotometry (Al-Kahtani 2009; Fernandes et al. 2008), inductively coupled plasma mass spectrometry (Kalantzi et al. 2013; Schenone et al. 2014) and differential thermal analysis (Najafi et al. 2013). Among these methods, voltammetry is one of the preferred techniques due to its high sensitivity, simplicity and environmental friendliness. What is more, the properties of working electrodes used in voltammetry may be easily improved by simple modifications of electrode material or surface to achieve better stability, reproducibility and selectivity. In recent years, there has been a growing interest in the use of graphene and graphene oxide in various types of studies (Wang et al. 2013, 2014; Wu et al. 2013) due to their promising properties (Chen et al. 2012) such as electron transport capability (Novoselov et al. 2005; Zhang et al. 2005), thermal and electrical conductivity (Balandin et al. 2008; Bolotin et al. 2008), mechanical stiffness (Lee et al. 2008) and unprecedented pliability and impermeability (Bunch et al. 2008; Lee et al. 2008). Graphene has been found to have a variety of applications, e.g. in sensors (Robinson et al. 2008), polymer composites (Domingues et al. 2011), transparent electrodes (Zhao et al. 2010; Blake et al. 2008) and hydrogen storage (Dimitrakakis et al. 2008). Up-to-date graphene and graphene oxide-modified carbon paste electrodes have been successfully applied for the determination of lead (Chen et al. 2013; Li et al. 2009; Wonsawat et al. 2012; Yang et al. 2011). In this paper, we report the application of a graphene oxide-modified carbon paste electrode for quantitative lead determination in rainbow trout muscle tissue under conditions of square wave anodic stripping voltammetry (SWASV). Both carbon paste electrodes and square wave voltammetry (SWV) are very popular in various fields of research. SW techniques owe their prevalence (Mirceski et al. 2011, 2013a, b; Pacheco et al. 2010; da Costa Fulgencio et al. 2014; Smarzewska et al. 2012, 2014; Snevajsova et al. 2010; Skrzypek et al. 2011; Nosal-Wiercinska and Dalmata 2009) to rapidity, simplicity and sensitivity, while carbon paste electrodes are cheap, stable and easy to modify (Svancara et al. 2005; Arvand and Kermanian 2013; Vazquez et al. 2012; Khaled et al. 2008; Kalcher 1990; Mailley et al. 2004; Fathirad et al. 2013).

Material and Methods

Instrumentation

A μAutolab Type III/General Purpose Electrochemical System (GPES, version 4.9; Eco Chemie, Netherlands) was used with an M164 electrode stand (mtm-anko, Cracow, Poland) for all voltammetric measurements. Experiments were performed in a typical three-electrode system with a working GO–CPE or hanging mercury drop electrode (HMDE), a reference Ag/AgCl electrode (3 mol L−1 KCl) and a counter electrode (Pt wire). Measurements of pH were made using a CP-315M pH meter (Elmetron, Poland) with a combined glass electrode.

Solutions and Materials

All the chemicals used (graphene oxide, graphite, paraffin oil, hydrochloric acid, perchloric acid, lead nitrate) were of analytical reagent grade and were purchased from Sigma-Aldrich. To prepare a graphene oxide–carbon paste electrode, 0.45 g of graphite powder, 0.05 g of graphene oxide and 150 μL of paraffin oil were mixed and homogenized (15 min) and then packed into a piston-driven carbon paste electrode holder. Before each experiment, the surface of the GO–CPE was refreshed by squeezing out a small portion of paste and polishing it with wet filter paper until a smooth surface was obtained.

SWASV Analysis

The general procedure adopted for obtaining adsorptive stripping voltammograms was as follows: the required aliquot of the analyzed working solution was placed in a cell containing a supporting electrolyte, deaerated by passing an argon stream for 600 s, and then stirred at a chosen accumulation potential throughout the selected accumulation period. Following the pre-concentration step, the stirrer was stopped, and after 3 s, scans were carried out over the range of −1.2 to +1.0 V using the SW technique. All measurements were made in a standard 10 mL voltammetric cell, at room temperature. In order to ensure the reliability of the experiments, all samples were also investigated using an HMDE electrode.

Preparation of Real Samples

Rainbow trout were purchased in Prague (Czech Republic), Lodz (Poland) and Bratislava (Slovakia) from local fish shops and large shopping malls belonging to popular chain stores. Fish samples were marked as shown in Scheme 1. Fish sample solutions were mineralized with a mixture of HClO4/HNO3 according to the method described in Sobhanardakani et al. (2012). After mineralization, the samples were filled up to volume (in 10-mL flasks) with 1:1 (v/v) water/0.1 M HCl mixture (sample solutions). Then, the rainbow trout were analyzed using the standard addition method. For each fish sample, some preliminary studies were conducted to adjust the amount of standard solution.

Scheme 1
scheme 1

Nomenclature of the samples

Linear Regression Equation, Calibration Curve and Sensitivity

Calibration curves (described with the linear regression equation y = bx + a) were constructed by plotting lead peak current (I, A) against lead concentration (C, mol L−1) on the basis of 12 (GO–CPE) or 11 (HMDE) lead standard solutions for the concentration ranges 1.0 × 10−7–7.0 × 10−5 and 1.0 × 10−7–5.0 × 10−5 mol L−1, respectively. To evaluate the sensitivity of SWASV analysis, the limit of detection (LOD) and the limit of quantification (LOQ) were determined. LOQ and LOD were calculated from the calibration curves as k SD / b (k = 10 for LOQ, k = 3 for LOD, SD = standard deviation of the intercept, b = slope of the calibration curve, dos Santos et al. 2004). For each concentration from the calibration curve, the coefficient of variation (CV) was calculated using the formula as follows: CV = (SD × C ave −1) × 100 %, where C ave represents the average lead concentration calculated from the linear regression equation and SD is the standard deviation of the calculated concentrations.

Precision and Accuracy

The precision of the developed method was evaluated for the GO–CPE by the coefficient of variation of three intra- and inter-day replicate measurements of CZ–FS–T and SK–FS–H samples done within 1 day and for three consecutive days, respectively. The accuracy of the SWASV method was determined by spike recovery. Appropriate amounts of lead nitrate standard solution were added into distilled water. Spiked distilled water solutions were mineralized and analyzed using the standard addition method under the experimental conditions as for fish samples described in “SWASV Analysis” and “Preparation of Real Samples” sections. The recovery of each spiked solution was calculated using the following formula: Recovery (%) = 100 + [(C ave − C spi) / (C spi)] × 100, where C spi is the actual lead concentration in a spiked sample and C ave is the average lead concentration calculated using the least-squares regression method on the basis of standard addition method results.

Results and Discussion

Influence of SW Parameters

Research work was started with the selection of supporting electrolyte. First, various supporting electrolytes were tested (BR buffers, acetate buffer, ammonia buffer, hydrochloric acid, nitric acid) in the pH range 0.5–10. The highest lead signals were recorded in acidic solutions pH 1.0–3.0. Although the recorded signals in pH 2.0 were 3–8 % higher (but had slightly worse morphology) than those in pH 1.0, in the preliminary studies, it was found that the pH of the mineralized samples was around 1.0; therefore, to ensure reliable and comparable results, pH 1.0 was chosen for all the experiments. Next, several supporting electrolyte solutions were examined at pH 1.0 in detail (hydrochloric acid, nitric acid, sulfuric acid and perchloric acid) with various techniques (LSV, DPV, SWV). The strongest, well-shaped signals were obtained in 0.1 M HCl solution for all the used techniques. Considering sensitivity and signal shape, SWASV was chosen for analytical purposes. Then, the influence of SWASV parameters on lead peak current was examined. During adjusting the above-mentioned parameters, each parameter was changed while the others were kept constant using 5 × 10−6 mol L−1 lead concentration. These parameters have correlative influence on the measured peak potential and current, but in this study, only the general tendencies were investigated. The studied square wave amplitude, step potential, frequency, accumulation potential and accumulation time ranges were 5–200 mV, 1–25 mV, 8–200 Hz, −2.0 to −0.6 V and 5–300 s, respectively. The optimized values were as follows: E sw = 50 mV, ΔE = 8 mV, f = 8 Hz, E acc = −0.9 V and t acc = 90 s.

Validation of the Developed Method

First, it is worth mentioning that lead signals recorded on GO–CPE electrode in optimized conditions were 15 % higher than those obtained on bare CPE. In our opinion, according to graphene oxide content in paste, modified electrode has better conductivity (as explained in the “Introduction” section). That was confirmed by resistance measurements; measured resistance for CPE and GO–CPE was equal to 235 and 147 Ω, respectively. In order to validate the developed SWASV analytical method, linearity, precision, accuracy, sensitivity and stability were evaluated. Linear regression equations, linearity, LOD and LOQ are presented in Table 1. Linearity is given by the correlation coefficient (R 2) and shows very good correlation with R 2 at 0.9997 in the range of 1.0 × 10−7–7.0 × 10−5 mol L−1 (GO–CPE). The LOD and LOQ were 2.18 × 10−8 and 7.24 × 10−8 mol L−1, respectively. The voltammograms recorded on the GO–CPE and HMDE during calibration curve examination are shown in Fig. 1.

Table 1 Quantitative determination of lead in 0.1 M HCl by SWASV. Basic statistic data of the regression line
Fig. 1
figure 1

SWASV voltammograms of lead in 0.1 M HCl on GO–CPE and HMDE, lead concentrations (in μmol L−1): a 0.10, b 0.50, c 1.0, d 3.0, e 5.0, f 7.0, g 10.0, h 30.0, i 50.00 and j 70.0. The other experimental conditions were as follows: amplitude (E sw) = 50 mV, step potential (ΔE) = 8 mV, frequency (f) = 8 Hz, accumulation potential (E acc) = −0.9 V and accumulation time (t acc) = 90 s

Repeatability of the procedure was estimated with three measurements at the same lead concentration. In order to check the correctness of the method, precision (expressed by CV) and recovery of the method were also calculated for different concentrations within the linear range (Table 2).

Table 2 Recovery and precision of the lead peak currents at various lead concentrations

Variations (CV) of the amount of lead found in samples SK–FS–H and CZ–FS–T were 1.37–4.68 %, indicating that the lead contained in the mineralized samples was stable for at least 72 h. Coefficient of variations for intra- and inter-day measurements is shown in Table 3. Overall variations did not exceed 2.1 % for intra-day runs and 4.7 % for inter-day runs.

Table 3 Precision test of the SWASV analysis on GO–CPE

Recoveries were also determined for the two spiked distilled water solutions. Each water sample was contaminated by the addition of a specified concentration of lead. An aliquot of each sample was added into the electrochemical cell, and recovery curves were constructed by the standard addition method, using the optimized parameters. Three replicate analyses were made for each sample. The least-squares regression method was used to evaluate the recovery percentage. The obtained SWV responses are shown in Fig. 2. The calculated recoveries of the analyzed samples varied in the range of 98.7–109.6 % (Table 4), demonstrating that the developed SWASV method was precise and accurate.

Fig. 2
figure 2

SWASV voltammograms of lead determination in spiked samples using standard addition method. Sample 1: s1 sample (1.0 μmol L−1) and a1/b1/c1 standard additions (1.0 × 10−8 mol); sample 2 (5.0 μmol L−1): s2 sample and a2/b2/c2 standard additions (5.0 × 10−8 mol) at GO–CPE and HMDE in 0.01 M HCl. Experimental conditions are the same as those in Fig. 1

Table 4 Determination of lead in spiked samples

Analysis of Rainbow Trout Samples

Analysis of real samples was preceded by testing of the used solutions for lead content. Samples of distilled water, supporting electrolyte and HClO4/HNO3 mixture were mineralized and analyzed as described in “SWASV Analysis” and “Preparation of Real Samples” sections. Lead was not detected in any of the samples. As described in the “Material and Methods” section, fish samples were mineralized and then analyzed using the standard addition method. As can be seen in Fig. 3, where sample voltammograms are shown, in each experiment, three additions of the standard were made. Amounts of the standard lead solution varied between samples from 1 × 10−8 to 1 × 10−7 mol due to differences in lead content between fish samples (for example, additions contained 2 × 10−8 and 8 × 10−8 mol of lead for CZ–FS–T and PL–SM–H samples, respectively). The lead content calculated for rainbow trout samples is shown in Table 5. Obtained results (for both electrodes) were compared with popular statistical tests (F test, Student’s t test). As it was calculated from F test, standard deviation values differ significantly in terms of precision only for sample CZ–SM–H. Student’s t test indicate that only results for samples SK–FS–H and SK–FS–T differ in a statistically significant way in terms of accuracy. Additionally, a linear relationship between lead content and fish length was observed. This relationship can be described with the following equation: m Pb (mg/100 g) = 0.046 l fish (cm) − 0.0597, where m Pb is the found amount of lead (in mg for 100 g of fish) and l fish is fish length. This relationship is probably due to the fact that the longer a fish lives (the length of fish increases with age), the longer is the time of lead accumulation.

Fig. 3
figure 3

SWASV voltammograms of lead determination in rainbow trout muscles using standard addition method (sample CZ–FS–T: s1 sample and a1/b1/c1 standard additions; sample PL–SM–H: s2 sample and a2/b2/c2 standard additions) on GO–CPE and HMDE in 0.01 M HCl. Experimental conditions are the same as those in Fig. 1

Table 5 Contents of lead in rainbow trout

Selectivity of the Method

The selectivity of the developed method was evaluated by the addition of possible interferents–heavy metals (zinc, mercury, cadmium, copper, nickel and cobalt). To 5 × 10−6 mol L−1 lead, solutions of interferents were added at concentration ratios of 1:1, 1:2 and 1:10. The responses were compared to those obtained for the pure standard lead solution. Only the presence of cadmium caused significant enhancement of the background current (without influencing the lead peak current). The other studied substances did not interfere with the determination of lead under the working conditions used (signal change <3 %).

Conclusions

Graphene oxide-modified carbon paste electrode was used in combination with the SWASV technique to develop a novel and alternative electroanalytical method for lead determination in real samples. The GO-modified electrode exhibits stability, reproducibility and favourable properties for quantitative lead determination. Micromolar concentrations of lead were determined by square wave anodic stripping voltammetry at the surface of the GO–CPE with a CV smaller than 5 %, recoveries in the range of 96.1 to 103.6 % and a LOQ of 7.24 × 10−8 mol L−1. The important point that should be emphasized is the environmental friendliness and/or low cost of the GO–CPE in comparison to e.g. metal film electrodes (Bi, Hg, Au) frequently used in lead determination. Furthermore, GO–CPE offers also a simple and rapid cleaning procedure, which allows for the use of the electrode for a long time with reproducible responses. The other benefits of the developed method such as rapidity and simplicity were proven by the successful application of the method to rainbow trout analysis following simple preparation of samples. It is worth noting that the results obtained on the GO–CPE are comparable with those obtained on the HMDE. The GO–CPE exhibits small variation coefficients, very good recoveries and a linear range even longer than that obtained for the HMDE. Such behaviour proves that mercury electrodes and metal film electrodes can be successfully replaced by environmentally friendly carbon electrodes with graphene oxide modifications, as the sensitivity exhibited by GO–CPE electrode is sufficient for real sample analysis.