Skip to main content

Advertisement

Log in

M.ALSHEIKH Technique: Modification to the Soft Tissue Reduction in the Baha® Attract Surgery

  • Original Article
  • Published:
Indian Journal of Otolaryngology and Head & Neck Surgery Aims and scope Submit manuscript

Abstract

To describe a modification to the Baha® Attract surgical technique that aims to enhance skin closure, create smooth skin across the surface of the wound, reduce surgery time, and improve cosmetics of the surgical site. Retrospective chart review. Patients were implanted between 2014 and 2016 at King Fahad General Hospital (KFGH) (Jeddah, Kingdom of Saudi Arabia). 20 adult patients (11 males, 9 females), all eligible for Baha® Attract system. One patient only had a previous Baha® surgery. The normal Baha® Attract surgical technique with modification to the soft tissue reduction stage is described. The mean surgical time was 35.25 min (range 25–55). Bleeding was present but not significant and easily controlled in four patients. All patients received the 4 mm implant. None of the patients experienced severe pain. The postoperative follow-up period was 6 months for 7 patients and 8 months for 13 patients. Patient feedback and monitoring indicates a good hearing performance and comfort in all patients. The modified Baha® Attract surgical method causes less postoperative complication, improve cosmetic effect, and provide shorter operative time compared to the conventional Attract procedure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Snik AF, Mylanus EA, Proops DW et al (2005) Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol 195:2–12

    Article  Google Scholar 

  2. de Wolf MJ, Shival ML, Hol MK et al (2010) Benefit and quality of life in older bone-anchored hearing aid users. Otol Neurotol 31:766–772

    Article  Google Scholar 

  3. McDermott AL, Williams J, Kuo M et al (2009) The Birmingham pediatric bone-anchored hearing aid program: a 15-year experience. Otol Neurotol 30:178–183

    Article  Google Scholar 

  4. Saliba I, Woods O, Caron C (2010) BAHA results in children at one year follow-up: a prospective longitudinal study. Int J Pediatr Otorhinolaryngol 74:1058–1062

    Article  Google Scholar 

  5. Desmet J, Bouzegta R, Hofkens A et al (2012) Clinical need for a BAHA trial in patients with single-sided sensorineural deafness. Analysis of a BAHA database of 196 patients. Eur Arch Otorhinolaryngol 269:799–805

    Article  Google Scholar 

  6. Burkey JM, Berenholz LP, Lippy WH (2006) Latent demand for the bone anchored hearing aid: the Lippy Group experience. Otol Neurotol 27:648–652

    Article  Google Scholar 

  7. Andersen HT, SchrLder SA, Bonding P (2006) Unilateral deafness after acoustic neuroma surgery: subjective hearing handicap and the effect of the bone-anchored hearing aid. Otol Neurotol 27:809–814

    Article  Google Scholar 

  8. Hol MK, Nelissen RC, Agterberg MJ, Cremers CW, Snik AF (2013) Comparison between a new implantable transcutaneous bone conductor and percutaneous bone-conduction hearing implant. Otol Neurotol 34:1071–1075

    Article  Google Scholar 

  9. Mulla O, Agada F, Reilly PG (2012) Introducing the Sophono Alpha 1 abutment free bone conduction hearing system. Clin Otolaryngol 37:168–169

    Article  CAS  Google Scholar 

  10. Siegert R, Kanderske J (2013) A new semi-implantable transcutaneous bone conduction device: clinical, surgical, and audiologic outcomes in patients with congenital ear canal atresia. Otol Neurotol 34:927–934

    Article  Google Scholar 

  11. Marsella P, Scorpecci A, Dalmasso G, Pacifico C (2015) First experience in Italy with a new transcutaneous bone conduction implant. Acta Otorhinolaryngol Ital 35(1):29–33

    CAS  PubMed  PubMed Central  Google Scholar 

  12. Işeri M, Orhan KS, Kara A, Durgut M, Oztürk M, Topdağ M, Calışkan S (2014) A new transcutaneous bone anchored hearing device—the Baha® Attract System: the first experience in Turkey. Kulak Burun Bogaz Ihtis Derg 24(2):59–64. doi:10.5606/kbbihtisas.2014.45143

    Article  PubMed  Google Scholar 

  13. Kurz A, Flynn M, Caversaccio M, Kompis M (2014) Speech understanding with a new implant technology: a comparative study with a new Nonskin Penetrating Baha System. BioMed Res Int 2014:Article ID 416205

  14. Briggs R, Van Hasselt A, Luntz M, Goycoolea M, Wigren S, Weber P, Smeds H, Flynn M, Cowan R (2015) Clinical performance of a new magnetic bone conduction hearing implant system: results from a prospective, multicenter, clinical investigation. Otol Neurotol. 36(5):834–841. doi:10.1097/MAO.0000000000000712

    Article  PubMed  Google Scholar 

  15. Clamp PJ, Briggs RJ (2015) The Cochlear Baha 4 Attract System—design concepts, surgical technique and early clinical results. Expert Rev Med Devices 12(3):223–230. doi:10.1586/17434440.2015.990375(Epub 2014 Dec 12)

    Article  CAS  PubMed  Google Scholar 

  16. Carr SD, Moraleda J, Procter V, Wright K, Ray J (2015) Initial UK experience with a novel magnetic transcutaneous bone conduction device. Otol Neurotol. 36(8):1399–1402. doi:10.1097/MAO.0000000000000830

    Article  PubMed  Google Scholar 

  17. Manorama A, Meyer R, Wiseman R, Bush TR (2013) Quantifying the effects of external shear loads on arterial and venous blood flow: implications for pressure ulcer development. Clin Biomech (Bristol, Avon) 28:574–578

    Article  Google Scholar 

  18. Raicevich G, Burwood E, Dillon H (2008) Taking the pressure off bone conduction hearing aid users. ANZJA 30:113–117

    Google Scholar 

  19. Yellin W, Roland PS, Culbertson M, Meyerhoff WL (1997) Use of an implantable hearing device. Am J Otoloaryngol 18:33–37

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Osama Majdalawieh.

Ethics declarations

Conflict of interest

All authors declares that they have no conflict of interest.

Ethical Approval

This study was approved by the Directorate of Health Affairs, National Committee of Medical and Bioethics, Ministry of Health, Jeddah, Kingdom of Saudi Arabia.

Informed Consent

All subjects, or their legal guardian, had previously granted consent to the use of relevant data.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

AlShaikh, M., Majdalawieh, O. & Kullab, A. M.ALSHEIKH Technique: Modification to the Soft Tissue Reduction in the Baha® Attract Surgery. Indian J Otolaryngol Head Neck Surg 71 (Suppl 2), 1053–1059 (2019). https://doi.org/10.1007/s12070-017-1110-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12070-017-1110-9

Keywords

Navigation