Abstract
Twenty experienced observers with nondefective color vision judged 27 virgin olive oil samples within an acceptable color range, using the bromthymol blue (BTB) method, under controlled observation conditions (daylight source with a correlated color temperature of 6500 K, and standard gray back-ground). On the average, 44.8% of the observers agreed in their selections of the BTB standard solution matching a given oil sample, and this percentage increased to 88.2% considering ±one step in the two dimensions (pH and concentration) of the BTB scale. On the average, the lowest color difference between oil samples and available BTB solutions was 6.6 Commission Internationale de l'Éclairage 1976-(L*a*b*) (CIELAB) units, but this color difference was approximately two times greater for the color difference between oil samples and BTB solutions selected by our observers. The colors of the BTB standard solutions in the CIELAB space are not uniformly distributed, and thus one step in pH or concentration is equivalent to CIELAB color differences varying in a wide range (1.7–13.5 and 1.7–26.3 CIELAB units, respectively). From these values, indicating low precision, accuracy, and uniformity, some suggestions are made for future improvements of the current BTB method.
Article PDF
Similar content being viewed by others
References
Gutiérrez, R., and F. Gutiérrez, Método Rápido para Definir el Color de los Aceites de Oliva Vírgenes, Grasas Aceites 37:282–284 (1986).
AENOR, Índice de Color ABT, Norma UNE 55021, Asociación Española de Normalización y Certificación, Madrid, 1997.
Moyano, M.J., M. Melgosa, J. Alba, E. Hita, and F.J. Heredia, Reliability of the Bromthymol Blue Method for Color in Virgin Olive Oils, J. Am. Oil. Chem. Soc. 76:687–692 (1999).
CIE Publication No. 15.2, Colorimetry (Technical Report), CIE Central Bureau, Vienna (1986).
Judd, D.B., and G. Wyszecki, Color in Business, Science and Industry, 3rd edn., pp. 274–275, John Wiley & Sons, New York 1975.
Robertson, A.R., Historical Development of CIE Recommended Color Difference Equations, Color Res. Appl. 15:167–170 (1990).
Kuehni, R.G., Industrial Color Difference: Progress and Problems, ——Ibid. 15:261–265 (1990).
Munsell Soil Color Charts, 1994 Revised Edition, Munsell Color. Macbeth Division of Kollmorgen Instruments Corporation, New Windsor, NY, 1994.
Fairchild, M.D., and L. Reniff, Propagation of Random Errors in Spectrophotometric Colorimetry, Color Res. Appl. 16:360–367 (1991).
CIE Publication No. 116, Industrial Color-Difference Evaluation (Technical Report). CIE Central Bureau, Vienna, 1995.
Martínez, J.M., E. Muñoz, J. Alba, and A. Lanzón, Informe sobre Utilización del Analizador de Rendimientos “Abencor”, Grasas Aceites 26:379–385 (1975).
Ishihara, S., Test for Color Blindness, 38th edn., Kanehara Shuppan Co., Tokyo, Japan, 1979.
Photo Research, PR-704 Operating Manual (Software Spectra View 2.10), Chatsworth, CA, 1991.
Luke, J.T., OSA Uniform Color Scales, Opt. Photonics News 10:28–33 (1999).
MacAdam, D.L., Uniform Color Scales, J. Opt. Soc. Am. 64:1691–1702 (1974).
Melgosa, M., Testing CIELAB-Based Color-Difference Formulas, Color Res. Appl. 25:49–55 (2000).
Melgosa, M., E. Hita, A.J. Poza, D.H. Alman, and R.S. Berns, Suprathreshold Color-Difference Ellipsoids for Surface Colors, ——Ibid. 22:148–155 (1997).
Kuehni, R.G., Towards an Improved Uniform Color Space, ——Ibid. 24:253–265 (1999).
Thomsen, K., A Euclidean Color Space in High Agreement with the CIE94 Color Difference Formula, ——Ibid. 25:64–65 (2000).
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Melgosa, M., Prez, M.M., Hita, E. et al. Precision and accuracy in the color specification of virgin olive oils from the bromthymol blue method. J Amer Oil Chem Soc 77, 1093–1100 (2000). https://doi.org/10.1007/s11746-000-0172-8
Received:
Accepted:
Issue Date: