Radiotherapy to the thoracic and abdominal regions can require tailoring of the planning target volume (PTV) to compensate for respiratory motion. We evaluated dose variations that might occur to a small target close to the diaphragm. We compared tumour and diaphragm displacement in gated and non-gated four-dimensional computed tomography (CT) of a patient with a peridiaphragmatic lesion, using peak exhalation as a baseline. Diaphragmatic motion was 12.7 mm in the inferior direction. The tumour was noted to move 1.0 mm to the right, 1.1 mm anteriorly, and 1.4 mm superiorly. The tumour moved in the opposite direction from the diaphragm in the vertical axis. This paradoxical motion did not affect the dose distribution because the beam did not irradiate the liver on non-gated treatment plans, and remained within the PTV. We observed minimal movement of a small tumour on 4D CT, in spite of it being in contact with, and moving opposite to, the diaphragm. In this patient, respiratory gating during irradiation was not needed, making it possible to reduce the treatment time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Bragg W, Kleeman R. On the ionisation curves of radium. Phil Mag. 1904;8:726–38.

    Article  CAS  Google Scholar 

  2. Mizumoto M, Okumura T, Hashimoto T, Fukuda K, Oshiro Y, Fukumitsu N, et al. Evaluation of liver function after proton beam therapy for hepatocellular carcinoma. Int J Radiat Oncol Biol Phys. 2012;82:e529–35.

    Article  PubMed  Google Scholar 

  3. Widesott L, Amichetti M, Schwarz M. Proton therapy in lung cancer: clinical outcomes and technical issues. A systematic review. Radiother Oncol. 2008;86:154–64.

    Article  PubMed  Google Scholar 

  4. Langen KM, Jones DT. Organ motion and its management. Int J Radiat Oncol Biol Phys. 2001;50:265–78.

    Article  CAS  PubMed  Google Scholar 

  5. Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, et al. The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys. 2006;33:3874–900.

    Article  PubMed  Google Scholar 

  6. Endo M, Mori S, Tsunoo T, Kandatsu S, Tanada S, Aradate H, et al. Development and performance evaluation of the first model of 4D CT-scanner. IEEE Trans Nucl Sci. 2003;50:1667–71.

    Article  Google Scholar 

  7. Mori S, Endo M, Tsunoo T, Kandatsu S, Tanada S, Aradatte H, et al. Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging. Med Phys. 2004;31:1348–56.

    Article  PubMed  Google Scholar 

  8. Giraud P, Antoine M, Larrouy A, Milleron B, Callard P, De Rycke Y, et al. Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning. Int J Radiat Oncol Biol Phys. 2000;48:1015–24.

    Article  CAS  PubMed  Google Scholar 

  9. Mori S, Wolfgang J, Lu HM, Schneider R, Choi NC, Chen GT. Quantitative assessment of range fluctuations in charged particle lung irradiation. Int J Radiat Oncol Biol Phys. 2008;70(1):253–61.

    Article  PubMed  Google Scholar 

  10. Mori S, Furukawa T, Inaniwa T, Zenklusen S, Nakao M, Shirai T, et al. Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy. Med Phys. 2013;40(3):031720.

    Article  PubMed  Google Scholar 

  11. Brock KK. Deformable registration accuracy consortium. Results of a multi-institution deformable registration accuracy study (MIDRAS). Int J Radiat Oncol Biol Phys. 2010;76:583–96.

    Article  PubMed  Google Scholar 

  12. Plathow C, Ley S, Fink C, Puderbach M, Hosch W, Schmahl A, et al. Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. Int J Radiat Oncol Biol Phys. 2004;59(4):952–9.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

We would like to express our appreciation to Naoyoshi Yamamoto, MD, and Mio Nakajima, MD for their useful discussion.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shinichiro Mori.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kumagai, M., Mori, S. Movement of a small tumour in contact with the diaphragm: characterisation with four-dimensional CT. Jpn J Radiol 34, 154–157 (2016). https://doi.org/10.1007/s11604-015-0509-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11604-015-0509-z

Keywords

Navigation