Abstract
Radiotherapy to the thoracic and abdominal regions can require tailoring of the planning target volume (PTV) to compensate for respiratory motion. We evaluated dose variations that might occur to a small target close to the diaphragm. We compared tumour and diaphragm displacement in gated and non-gated four-dimensional computed tomography (CT) of a patient with a peridiaphragmatic lesion, using peak exhalation as a baseline. Diaphragmatic motion was 12.7 mm in the inferior direction. The tumour was noted to move 1.0 mm to the right, 1.1 mm anteriorly, and 1.4 mm superiorly. The tumour moved in the opposite direction from the diaphragm in the vertical axis. This paradoxical motion did not affect the dose distribution because the beam did not irradiate the liver on non-gated treatment plans, and remained within the PTV. We observed minimal movement of a small tumour on 4D CT, in spite of it being in contact with, and moving opposite to, the diaphragm. In this patient, respiratory gating during irradiation was not needed, making it possible to reduce the treatment time.
Similar content being viewed by others
References
Bragg W, Kleeman R. On the ionisation curves of radium. Phil Mag. 1904;8:726–38.
Mizumoto M, Okumura T, Hashimoto T, Fukuda K, Oshiro Y, Fukumitsu N, et al. Evaluation of liver function after proton beam therapy for hepatocellular carcinoma. Int J Radiat Oncol Biol Phys. 2012;82:e529–35.
Widesott L, Amichetti M, Schwarz M. Proton therapy in lung cancer: clinical outcomes and technical issues. A systematic review. Radiother Oncol. 2008;86:154–64.
Langen KM, Jones DT. Organ motion and its management. Int J Radiat Oncol Biol Phys. 2001;50:265–78.
Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, et al. The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys. 2006;33:3874–900.
Endo M, Mori S, Tsunoo T, Kandatsu S, Tanada S, Aradate H, et al. Development and performance evaluation of the first model of 4D CT-scanner. IEEE Trans Nucl Sci. 2003;50:1667–71.
Mori S, Endo M, Tsunoo T, Kandatsu S, Tanada S, Aradatte H, et al. Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging. Med Phys. 2004;31:1348–56.
Giraud P, Antoine M, Larrouy A, Milleron B, Callard P, De Rycke Y, et al. Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning. Int J Radiat Oncol Biol Phys. 2000;48:1015–24.
Mori S, Wolfgang J, Lu HM, Schneider R, Choi NC, Chen GT. Quantitative assessment of range fluctuations in charged particle lung irradiation. Int J Radiat Oncol Biol Phys. 2008;70(1):253–61.
Mori S, Furukawa T, Inaniwa T, Zenklusen S, Nakao M, Shirai T, et al. Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy. Med Phys. 2013;40(3):031720.
Brock KK. Deformable registration accuracy consortium. Results of a multi-institution deformable registration accuracy study (MIDRAS). Int J Radiat Oncol Biol Phys. 2010;76:583–96.
Plathow C, Ley S, Fink C, Puderbach M, Hosch W, Schmahl A, et al. Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. Int J Radiat Oncol Biol Phys. 2004;59(4):952–9.
Acknowledgments
We would like to express our appreciation to Naoyoshi Yamamoto, MD, and Mio Nakajima, MD for their useful discussion.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
About this article
Cite this article
Kumagai, M., Mori, S. Movement of a small tumour in contact with the diaphragm: characterisation with four-dimensional CT. Jpn J Radiol 34, 154–157 (2016). https://doi.org/10.1007/s11604-015-0509-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-015-0509-z