Abstract
Magnetic resonance imaging (MRI) using fast sequences with subjects staring at a target can provide motion-free ocular images, and small receiver surface coils make it possible to produce ocular images with high spatial resolution. MRI using half-Fourier single-shot rapid acquisition with a relaxation enhancement sequence as a fast T2-weighted imaging yields useful images for the morphologic diagnosis of ocular diseases, and MRI using a fast spoiled gradient-recalled-echo sequence as a T1-weighted imaging yields additional information by the administration of gadolinium-based contrast material for assessing the vascularity of intraocular tumors. These ocular imaging techniques are useful for the evaluation of patients with angle closure glaucoma, congenital abnormality of ocular globes, intraocular tumors and several types of detachments, as well as patients after ocular surgery. In this pictorial essay, we demonstrate the clinical applications of fast high-resolution ocular MRI with fixation of the subjects’ visual foci.
Similar content being viewed by others
References
Kuker W, Ramaekers V. Persistent hyperplastic primary vitreous: MRI. Neuroradiology. 1999;41:520–2.
Lee JS, Lee JE, Shin YG, Choi HY, Oum BS, Kim HJ. Five cases of microphthalmia with other ocular malformations. Korean J Ophthalmol. 2001;15:41–7.
de Graaf P, Goricke S, Rodjan F, Galluzzi P, Maeder P, Castelijns JA, et al. Guidelines for imaging retinoblastoma: imaging principles and MRI standardization. Pediatr Radiol. 2012;42:2–14.
Roshdy N, Shahin M, Kishk H, Ghanem AA, El-Khouly S, Mousa A, et al. MRI in diagnosis of orbital masses. Curr Eye Res. 2010;35:986–91.
Joseph DP, Pieramici DJ, Beauchamp NJ Jr. Computed tomography in the diagnosis and prognosis of open-globe injuries. Ophthalmology. 2000;107:1899–906.
Rao SK, Nunez D, Gahbauer H. MRI evaluation of an open globe injury. Emerg Radiol. 2003;10:144–6.
Pop-Fanea L, Vallespin SN, Hutchison JM, Forrester JV, Seton HC, Foster MA, et al. Evaluation of MRI for in vivo monitoring of retinal damage and detachment in experimental ocular inflammation. Magn Reson Med. 2005;53:61–8.
McNicholas MM, Brophy DP, Power WJ, Griffin JF. Ocular sonography. AJR Am J Roentgenol. 1994;163:921–6.
Lemke AJ, Kazi I, Felix R. Magnetic resonance imaging of orbital tumors. Eur Radiol. 2006;16:2207–19.
McCaffery S, Simon EM, Fischbein NJ, Rowley HA, Shimikawa A, Lin S, et al. Three-dimensional high-resolution magnetic resonance imaging of ocular and orbital malignancies. Arch Ophthalmol. 2002;120:747–54.
Tanitame K, Sasaki K, Sone T, Uyama S, Sumida M, Ichiki T, et al. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil. Radiology. 2008;249:294–300.
Tanitame K, Sasaki K, Sone T, Otani K. Optimal fast T2-weighted magnetic resonance microscopy imaging of the eye and its clinical application. J Magn Reson Imaging. 2010;31:1210–4.
Obata T, Uemura K, Nonaka H, Tamura M, Tanada S, Ikehira H. Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts. Magn Reson Imaging. 2006;24:97–101.
Rodjan F, de Graaf P, van der Valk P, Moll AC, Kuijer JP, Knol DL, et al. Retinoblastoma: value of dynamic contrast-enhanced mr imaging and correlation with tumor angiogenesis. AJNR Am J Neuroradiol. 2012 [Epub ahead of print].
Swanger RS, Crum AV, Klett ZG, Bokhari SA. Postsurgical imaging of the globe. Semin Ultrasound CT MR. 2011;32:57–63.
Conflict of interest
All authors have no conflicts of interest or financial disclosures.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Tanitame, K., Sone, T., Kiuchi, Y. et al. Clinical applications of high-resolution ocular magnetic resonance imaging. Jpn J Radiol 30, 695–705 (2012). https://doi.org/10.1007/s11604-012-0118-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-012-0118-z