Abstract
Technetium-99m human serum albumindiethylenetriaminepentaacetic acid (HSA-DTPA) lymphoscintigraphy with single photon emission computed tomography combined with integrated low-dose computed tomography (SPECT/CT) is useful for evaluating chylothorax. We report a case of chylothorax that occurred 2 months after childbirth in a 24-year-old woman. Lymphoscintigraphy with SPECT/CT showed abnormal tracer accumulation in the right plural effusion, and chylothorax was diagnosed. Collateral branches of the thoracic duct were found to be ruptured during video-assisted thoracoscopic surgery performed for ligation.
Similar content being viewed by others
References
Pui MH, Yueh TC. Lymphoscintigraphy in chyluria, chyloperitoneum and chylothorax. J Nucl Med 1998;39:1292–1296.
Suga K, Kume N, Hara A, Miura G, Matsunaga N, Sugi K, et al. Abnormal lymphatic flow demonstrated by lymphoscintigraphy in chylothorax: correlation with lymphography. Clin Nucl Med 1999;24:716–717.
Sun SS, Tsai SC, Hsu NY, Shih CS, Lee JK, Kao CH. Preoperative and postoperative lymphoscintigraphy using Tc-99m sulfur colloid in the repair of a lymphatic leak in a patient with traumatic chylothorax. Clin Nucl Med 2000;25:840–841.
Inoue Y, Otake T, Nishikawa J, Sasaki Y. Lymphoscintigraphy using Tc-99m human serum albumin in chylothorax. Clin Nucl Med 1997;22:60.
Ogi S, Fukumitsu N, Uchiyama M, Mori Y. A case of chylothorax diagnosed by lymphoscintigraphy using Tc-99m HASDTPA. Clin Nucl Med 2002;27:455–456.
Gayed IW, Kim EE, Broussard WF, Evans D, Lee J, Broemeling LD, et al. The value of 99mTc-sestamibi SPECT/CT over conventional SPECT in the evaluation of parathyroid adenomas or hyperplasia. J Nucl Med 2005;46:248–252.
Ruf J, Lehmkuhl L, Bertram H, Sandrock D, Amthauer H, Humplik B, et al. Impact of SPECT and integrated low-dose CT after radioiodine therapy on the management of patients with thyroid carcinoma. Nucl Med Commun 2004;25:1177–1182.
Palumbo B, Sivolella S, Palumbo I, Liberati AM, Paluumbo R. 67Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma. Eur J Nucl Med Mol Imaging 2005;32:1011–1017.
Lerman H, Metser U, Lievshitz G, Sperber F, Shneebaum S, Even-Sapir E. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT. Eur J Nucl Med Mol Imaging 2006;33:329–337.
Cammarata SK, Brush RE Jr, Hyzy RC. Chylothorax after childbirth. Chest 1991;99:1539–1540.
Tornling G, Axelsson G, Peterffy A. Chylothorax as a complication after delivery. Acta Obstet Gynecol Scand 1987;66:381–382.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Momose, M., Kawakami, S., Koizumi, T. et al. Lymphoscintigraphy using technetium-99m HSA-DTPA with SPECT/CT in chylothorax after childbirth. Radiat Med 26, 508–511 (2008). https://doi.org/10.1007/s11604-008-0265-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-008-0265-4