Skip to main content
Log in

Application of delayed neutron counting at CIAE

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Delayed neutron counting (DNC) was applied in quantitative determination of 235U/238U, quantitative determination of 235U and 239Pu in 235U–239Pu co-existing samples at China Institute of Atomic Energy (CIAE). In this work, natural uranium, enriched uranium and their mixtures were used in the determinations of 235U/238U ratios. The results indicated that delayed neuron counting combined with neutron activation analysis(NAA) and k0-NAA for the measurement of gamma rays emitted by 239U decay is suitable for fast determination 235U/238U ratio. In addition, the contents of 235U and 239Pu in 235U–239Pu co-existing samples can also be determined respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Sellers MT, Kelly DG, Corcoran EC (2012) An automated delayed neutron counting system for mass determinations of special nuclear materials. J Radioanal Nucl Chem. doi:10.1007/s10967-011-1223-7

    Google Scholar 

  2. Andrews MT, Corcoran EC, Goorley JT (2015) A system for the measurement of delayed neutrons and gammas from special nuclear materials. J Radioanal Nucl Chem 303:2431–2437

    CAS  Google Scholar 

  3. Eriksson SM, Mackey EA, Lindstrom RM (2013) Delayed-neutron activation analysis at NIST. J Radioanal Nucl Chem 298:1819–1822

    Article  CAS  Google Scholar 

  4. Li X, Henkelmann R, Baumgartner F (2004) Rapid determination of uranium and plutonium content in mixtures through measurement of the intensity–time curve of delayed neutrons. Nucl Instrum Method Phys Res Sec B 215:246–251

    Article  CAS  Google Scholar 

  5. Kapsimalis R, Glasgow D, Anderson B (2013) The simultaneous determination of 235U and 239Pu using delayed neutron activation analysis. J Radioanal Nucl Chem 298:1721–1726

    Article  CAS  Google Scholar 

  6. Glasgow DC (2008) Delayed neutron activation analysis for safeguards. J Radioanal Nucl Chem 276(1):207–211

    Article  CAS  Google Scholar 

  7. Moon JH, Kim SH, Chung YS (2009) U determination in environmental samples by delayed neutron activation analysis in Korea. J Radioanal Nucl Chem 282:33–35

    Article  CAS  Google Scholar 

  8. Xiao C, Yuan G, Jin X (2016) Delayed neutron counting at CIAE. J Radioanal Nucl Chem 307:1657–1659

    Article  CAS  Google Scholar 

  9. De Corte F, Simonits A (2003) Recommended nuclear data for use in the k0 standardization of neutron activation analysis. At Data Nucl Data Table 85:47–67

    Article  Google Scholar 

  10. Arbocco FF, Vermaercke P, Sneyers L (2010) The use of k0-NAA for the determination of the n(235U)/n(238U) isotopic ratio in samples containing uranium. Nucl Instrum Method Phys Res A 622:443–448

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by the National Natural Science Foundation of China (No.11175264, No. 11275276). We thank Professor Yongbao Zhang for assisting these experiments at MNSR reactor.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Caijin Xiao.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xiao, C., Yao, Y., Jin, X. et al. Application of delayed neutron counting at CIAE. J Radioanal Nucl Chem 312, 711–715 (2017). https://doi.org/10.1007/s10967-017-5215-0

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-017-5215-0

Keywords

Navigation