Abstract
Delayed neutron counting (DNC) was applied in quantitative determination of 235U/238U, quantitative determination of 235U and 239Pu in 235U–239Pu co-existing samples at China Institute of Atomic Energy (CIAE). In this work, natural uranium, enriched uranium and their mixtures were used in the determinations of 235U/238U ratios. The results indicated that delayed neuron counting combined with neutron activation analysis(NAA) and k0-NAA for the measurement of gamma rays emitted by 239U decay is suitable for fast determination 235U/238U ratio. In addition, the contents of 235U and 239Pu in 235U–239Pu co-existing samples can also be determined respectively.
Similar content being viewed by others
References
Sellers MT, Kelly DG, Corcoran EC (2012) An automated delayed neutron counting system for mass determinations of special nuclear materials. J Radioanal Nucl Chem. doi:10.1007/s10967-011-1223-7
Andrews MT, Corcoran EC, Goorley JT (2015) A system for the measurement of delayed neutrons and gammas from special nuclear materials. J Radioanal Nucl Chem 303:2431–2437
Eriksson SM, Mackey EA, Lindstrom RM (2013) Delayed-neutron activation analysis at NIST. J Radioanal Nucl Chem 298:1819–1822
Li X, Henkelmann R, Baumgartner F (2004) Rapid determination of uranium and plutonium content in mixtures through measurement of the intensity–time curve of delayed neutrons. Nucl Instrum Method Phys Res Sec B 215:246–251
Kapsimalis R, Glasgow D, Anderson B (2013) The simultaneous determination of 235U and 239Pu using delayed neutron activation analysis. J Radioanal Nucl Chem 298:1721–1726
Glasgow DC (2008) Delayed neutron activation analysis for safeguards. J Radioanal Nucl Chem 276(1):207–211
Moon JH, Kim SH, Chung YS (2009) U determination in environmental samples by delayed neutron activation analysis in Korea. J Radioanal Nucl Chem 282:33–35
Xiao C, Yuan G, Jin X (2016) Delayed neutron counting at CIAE. J Radioanal Nucl Chem 307:1657–1659
De Corte F, Simonits A (2003) Recommended nuclear data for use in the k0 standardization of neutron activation analysis. At Data Nucl Data Table 85:47–67
Arbocco FF, Vermaercke P, Sneyers L (2010) The use of k0-NAA for the determination of the n(235U)/n(238U) isotopic ratio in samples containing uranium. Nucl Instrum Method Phys Res A 622:443–448
Acknowledgements
This work was supported by the National Natural Science Foundation of China (No.11175264, No. 11275276). We thank Professor Yongbao Zhang for assisting these experiments at MNSR reactor.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Xiao, C., Yao, Y., Jin, X. et al. Application of delayed neutron counting at CIAE. J Radioanal Nucl Chem 312, 711–715 (2017). https://doi.org/10.1007/s10967-017-5215-0
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-017-5215-0