Abstract
This method uses stacked column separations consisting of different commercial products pre-filter material, DGA® Resin from Eichrom Technologies and AnaLig® Pu-02 gel, AnaLig® Sr-01 gel from IBC Advanced Technologies. Raw urine was acidified and passed directly through the resin columns. The method was successfully tested by adding of National Physical Laboratory (NPL) Alpha–Beta High 2005 sample with known activities of radionucledes to urine samples. The demonstrated linear model clearly proves that the residua fulfill the Gaussian model, without any autocorrelation and trend for intercomparison NPL Alpha–Beta High 2005 sample. By eliminating the co-precipitation techniques and the ashing steps to remove residual organics, the analysis time was reduced significantly.
Similar content being viewed by others
References
Kumar R, Dubla R, Yadav JR, Rao DD (2013) J Radioanal Nucl Chem 295:2147–2152
Kumar R, Yadav JR, Rao DD (2011) J Radioanal Nucl Chem 289:451–454
Jia GG, Bazzari S, Micci F, Testa C (1994) J Radioanal Nucl Chem 178(1):11–18
International Atomic Energy Agency (1992) Assessment of radiological consequences and evaluation of protective measures, The International Chernobyl Project, Technical report of the IAEA
Dulanská S, Remenec B, Bilohuščin J, Labaška M, Galanda D (2013) J Radioanal Nucl Chem 295:2189–2192
Lee MH, Ahn HJ, Park JH, Park YJ, Song K (2011) Appl Radiat Isot 69(2):295–298
Maxwell SL III, Culligan BK (2009) J Radioanal Nucl Chem 279:901–907
Dulanská S, Remenec B, Mátel Ľ, Galanda D (2011) J Radioanal Nucl Chem 287(3):841–845
Sill CW (1987) Nucl Chem Waste Manag 7:201–215
Hindman FD (1983) Anal Chem 55(14):2460–2461
Guide to the Expression of Uncertainty in Measurement, first edition, 1993, corrected and reprinted 1995, International Organization for Standardization (Geneva, Switzerland)
Eichrom Industries Inc. http://www.eichrom.com/products/info/prefilter.aspx. Accessed 02 Feb 2013
Dulanská S, Remenec B, Mátel Ľ, Antalík I (2012) J Radioanal Nucl Chem 292:97–101
Eichrom Industries Inc., http://www.eichrom.com/products/info/dga_resin.cfm. Accessed 02 Feb 2013
Sidhu R (2006) Radiochemical procedures for the determination of Sr, U, Pu, Am and Cm, ISBN 87-7893-185-1. http://www.nks.org/download/pdf/NKS-Pub/NKS-124.pdf Accessed 20 July 2014
Ansoborlo E, Prat O, Moisy P, Den Auwer C, Guilbaud P, Carriere M, Gouget B, Duffield J, Doizi D, Vercouter T, Moulin C, Moulin V (2006) Biochemie 88(11):1605–1618
Popplewell DS, Stradling GN, Ham GJ (1975) Radiat Res 62(3):513–519
Currie LL (1968) Anal Chem 40:586–593
Meloun M, Militký J (2006) Kompendium statistického zpracování dat (Compendium of statistical data treatment). pp 609–629. Academia, Prague, ISBN 80-200-1396-2 (In Czech)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Dulanská, S., Bilohuščin, J., Remenec, B. et al. Determination of 239Pu, 241Am and 90Sr in urine using pre-filter material and combined sorbents AnaLig® Pu-02, AnaLig® Sr-01, DGA® Resin. J Radioanal Nucl Chem 304, 127–132 (2015). https://doi.org/10.1007/s10967-014-3750-5
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-014-3750-5