Abstract
The B54X position of the 8 MW RA3 research reactor at the Ezeiza Atomic Centre of the Argentine National Atomic Energy Commission is currently being used for NAA irradiations. The facility with a nominal average fluence of 5 × 1013 cm−2 s−1 is dedicated to long irradiations of up to 5 h. Samples are being measured after a decay of typically 7 and 30 days. With the aim of implementing the k 0-NAA method at the Nuclear Analytical Techniques Laboratory of the Centre, the reactor parameters α and f were estimated applying multi monitor methods using the Kayzero for Windows software. After a careful recalibration of the HPGe detector, SMELS III, NIST SRM 1633b and several other matrix RM’s were analyzed using the k 0 standardization in order to verify the proper implementation of the k 0-NAA approach. The found accuracy and associated uncertainties are discussed. In general, good agreement was obtained between results of this work and the reference values of the individual reference materials, thus proving successful first implementation of the above method and trueness of the results achieved. The obtained detection limits for several elements were evaluated.
Similar content being viewed by others
References
Simonits A, De Corte F, Hoste J (1975) J Radioanal Chem 24:31
De Corte F (1987) The k 0 standardization method: a move to the optimization of NAA. University of Gent, Gent
Vermaercke P, Sneyers L, Bruggeman M, De Wispelaere A, De Corte F (2008) J Radioanal Chem 278–3:631–636
Kolotov VP, Atrashkevich VV, Gelsema S (1996) J Radioanal Nucl Chem 210:183
de Corte F (1994) A. Simonits vademecum for k 0-users. DSM Research, Geleen
De Corte F, Sordo-El Hammami K, Moens L, Simonits A, De Wispelaere A, Hoste J (1981) J Radioanal Nucl Chem 62:209
Vermaercke P, Robouch P, Eguskiza M, De Corte F, Kennedy G, Smodis B, Jacimovic R, Yonezawa C, Matsue H, Lin X, Blaauw M, Kučera J (2006) Nucl Instrum Methods Phys Res A564:675
ISO 13528 (2005) Statistical methods for use in proficiency testing by interlaboratory comparisons. ISO, Geneva
Robouch P, Eguskiza G, Pomme S, Etxebarria N (2000) J Radioanal Nucl Chem 245(1):195
Acknowledgments
The authors would like to thank Rita R. Plá for her valuable assistance during the preparation of this manuscript. This work was performed under project ARG0013 02 of the International Atomic Energy Agency.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jasan, R.C., Invernizzi, R. & Vermaercke, P. Calibration of the B54X channel and implementation of k 0-NAA at the RA3-reactor, Ezeiza, Argentina. J Radioanal Nucl Chem 300, 489–497 (2014). https://doi.org/10.1007/s10967-014-3067-4
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-014-3067-4