Calibration of the B54X channel and implementation of k 0-NAA at the RA3-reactor, Ezeiza, Argentina

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The B54X position of the 8 MW RA3 research reactor at the Ezeiza Atomic Centre of the Argentine National Atomic Energy Commission is currently being used for NAA irradiations. The facility with a nominal average fluence of 5 × 1013 cm−2 s−1 is dedicated to long irradiations of up to 5 h. Samples are being measured after a decay of typically 7 and 30 days. With the aim of implementing the k 0-NAA method at the Nuclear Analytical Techniques Laboratory of the Centre, the reactor parameters α and f were estimated applying multi monitor methods using the Kayzero for Windows software. After a careful recalibration of the HPGe detector, SMELS III, NIST SRM 1633b and several other matrix RM’s were analyzed using the k 0 standardization in order to verify the proper implementation of the k 0-NAA approach. The found accuracy and associated uncertainties are discussed. In general, good agreement was obtained between results of this work and the reference values of the individual reference materials, thus proving successful first implementation of the above method and trueness of the results achieved. The obtained detection limits for several elements were evaluated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Simonits A, De Corte F, Hoste J (1975) J Radioanal Chem 24:31

    Article  CAS  Google Scholar 

  2. De Corte F (1987) The k 0 standardization method: a move to the optimization of NAA. University of Gent, Gent

    Google Scholar 

  3. Vermaercke P, Sneyers L, Bruggeman M, De Wispelaere A, De Corte F (2008) J Radioanal Chem 278–3:631–636

    Article  Google Scholar 

  4. Kolotov VP, Atrashkevich VV, Gelsema S (1996) J Radioanal Nucl Chem 210:183

    Article  CAS  Google Scholar 

  5. de Corte F (1994) A. Simonits vademecum for k 0-users. DSM Research, Geleen

    Google Scholar 

  6. De Corte F, Sordo-El Hammami K, Moens L, Simonits A, De Wispelaere A, Hoste J (1981) J Radioanal Nucl Chem 62:209

    Article  Google Scholar 

  7. Vermaercke P, Robouch P, Eguskiza M, De Corte F, Kennedy G, Smodis B, Jacimovic R, Yonezawa C, Matsue H, Lin X, Blaauw M, Kučera J (2006) Nucl Instrum Methods Phys Res A564:675

    Article  Google Scholar 

  8. ISO 13528 (2005) Statistical methods for use in proficiency testing by interlaboratory comparisons. ISO, Geneva

    Google Scholar 

  9. Robouch P, Eguskiza G, Pomme S, Etxebarria N (2000) J Radioanal Nucl Chem 245(1):195

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Rita R. Plá for her valuable assistance during the preparation of this manuscript. This work was performed under project ARG0013 02 of the International Atomic Energy Agency.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. C. Jasan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jasan, R.C., Invernizzi, R. & Vermaercke, P. Calibration of the B54X channel and implementation of k 0-NAA at the RA3-reactor, Ezeiza, Argentina. J Radioanal Nucl Chem 300, 489–497 (2014). https://doi.org/10.1007/s10967-014-3067-4

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-014-3067-4

Keywords

Navigation