Skip to main content
Log in

Paul Ion Trap as a Diagnostic for Plasma Focus

  • Communication
  • Published:
Journal of Fusion Energy Aims and scope Submit manuscript

Abstract

The plasma discharge contamination by high and low Z Impurities affect the rate of nuclear fusion reaction products, specially when light particles have to be confined. These impurities should be analyzed and can be fairly controlled. This paper reports on the development of a Paul ion trap with ion sources by impact electron ionization as a diagnostic for the 10 kJ Iranian sunshine plasma focus device. Preliminary results of the residual gas are analyzed and presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. A. Asle-Zaeem, S.M. Sadat kiai, M. Sedaghatizadeh, A. Talaei, Plasma focus device as a breeder of 14.66 Mev protons to produce short-lived radioisotopes. J. Fusion Energy (accepted for publication 2009)

  2. A.A. Zaeem et al., Activities study of short-lived radioisotopes with a Filippov-type, plasma focus. J. Fusion Energy, 6 November 2008

  3. M.V. Roshan, S.V. Springham, A.R. Talebitaher, R.S. Rawat, P. Lee, Nuclear activation measurements of high energy deuterons from a small plasma focus. Phys. Lett. A 373, 851–855 (2009)

    Article  ADS  Google Scholar 

  4. M.V. Roshan, A.R. Babazadeh, S.M. Sadat Kiai, H. Habibi, M. Mamarzadeh, Investigation of plasma facing components in plasma focus operation. J. Fusion Energy 26(3), 313–316 (2007)

    Article  Google Scholar 

  5. M.V. Roshan, R.S. Rawat, A.R. Babazadeh, M. Emami, S.M. Sadat Kiai, R. Verma, A. Talebitaher, J.J. Lin, P. Lee, S.V. Springham, High energy ions and energetic plasma irradiation effects on aluminum in a Filippov-type plasma focus. Appl. Surf. Sci. 255(5), 2461–2465 (2008). (Part 1)

    Article  ADS  Google Scholar 

  6. R.C. Isler, Nucl. Fusion 24, 1599 (1984)

    Google Scholar 

  7. R.A. Hulse, Atomic and plasma-material interaction processes in controlled thermonuclear fusion. Elsevier (1993)

  8. A. Talaei, S.M. Sadat Kiai, Study the Effects of Heavy Admixture Gases on the Enhancement of Neutron Production in Plasma Focus Devices (Nuclear Science and Technology Research Institute (NSTR), Nuclear Science Research School, A.E.O.I., 14155-1339, Tehran, 2009, article in preparation)

  9. I.H. Hutchinson, Principles of Plasma Diagnostics, ch. 9 (Published in Academic Cambridge University press, Cambridge, 1990), p. 370

    Google Scholar 

  10. M. Zakaullah et al., Imaging of fusion reaction zone in plasma focus. Plasma Phys. 6(8), 3188 (1999)

    Article  Google Scholar 

  11. V.A. Gribkov et al., Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives. J. Phys. D Appl. Phys. 40, 3592–3607 (2007)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. M. Sadat Kiai.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sadat Kiai, S.M., Adlparvar, S., Zirak, A. et al. Paul Ion Trap as a Diagnostic for Plasma Focus. J Fusion Energ 29, 100–102 (2010). https://doi.org/10.1007/s10894-009-9253-7

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10894-009-9253-7

Keywords

Navigation