Performance of CF/PA12 composite femoral stems

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

This study presents the microstructural and mechanical behavior of the CF/PA12 composite material developed as well as its biomechanical performance when used for the fabrication of femoral stems. The static tests were performed to evaluate the compressive and flexural modulus as well as the ultimate compressive and bending strength. It was found that CF/PA12 composite had bone-matching properties in the same order of magnitude as cortical bone in the femur. Density and void content measurements were also done to assess the consolidation quality. Dynamic fatigue testing was conducted on both CF/PA12 cylinders and femoral stems to evaluate the long term durability and mechanical reliability of the composite. Compression–compression cyclic loading was used at a frequency of 6 Hz with loads varying between 17 kN and 22 kN for the composite cylinders while a frequency of 10 Hz and load of 2300 N was employed for the femoral stems. Results indicate that the fatigue performance of CF/PA12 composite surpasses by far the required fatigue performance for total hip prosthesis (THP) stems. The overall performance of the CF/PA12 femoral stems confirms that this composite is an excellent candidate material for orthopedic applications such as THP stems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  1. S. KURTZ, E. LAU, K. ZHAO, F. MOWAT, K. ONG, and M. HALPERN, in 73rd Annual Meeting of the American Academy of Orthopaedic Surgeons (Chicago, IL, 2006)

  2. D. TAYLOR, C. MARTIN, B. CORNELIS and M. E. B. JONES, J. Eng. Med. 207(2) (1993) 121

    Article  CAS  Google Scholar 

  3. H. BOUGHERARA, M. N. BUREAU, M. CAMPBELL, A. VADEAN and L’H. YAHIA, J. Biomed. Mater. Res. A. 82A(1) (2007) 27

    Article  CAS  Google Scholar 

  4. A. REINHARDT, S. G. ADVANI, M. H. SANTARE and F. MILLER, J. Compos. Mater. 33(9) (1999) 853

    Google Scholar 

  5. J. A. SIMOES and A. T. MARQUES, Comp. Sci. Tech. 60 (2000) 559

    Article  CAS  Google Scholar 

  6. J. A. SIMOES and A. T. MARQUES, Compos. Part A 32 (2001) 655

    Article  Google Scholar 

  7. J. A. SIMOES and A. T. MARQUES, Mater. Des. 26 (2005) 391

    CAS  Google Scholar 

  8. F. K. CHANG, J. L. PEREZ and J. A. DAVIDSON, J. Biomed. Mater. Res. 24(7) (1990) 873

    Article  CAS  Google Scholar 

  9. R. DE SANTIS, L. AMBROSIO and L. NICOLAIS, J. Inorg. Biochem. 79(1–4) (2000) 97

    Google Scholar 

  10. F. ADAM, D. S. HAMMER, S. PFAUTSCH and K. WESTERMANN, J. Arthroplasty 17(2) (2002) 217

    Article  Google Scholar 

  11. M. AKAY and N. ASLAN, J. Biomed. Mater. Res. 31 (1996) 167

    Article  CAS  Google Scholar 

  12. J. R. BRITTON, C. G. C. LYONS and P. J. PRENDERGAST, Strain 40 (2004) 193

    Article  Google Scholar 

  13. J.-G. LEGOUX, F. CHELLAT, R. LIMA, B. MARPLE, M. N. BUREAU, H. SHEN and G. A. CANDELIERE, J. Thermal Spray Technol. 15(4) (2006) 629

    Article  Google Scholar 

  14. K. CHOI and S. A. GOLDSTEIN, J. Biomech. 25(12) (1992) 1371

    Article  CAS  Google Scholar 

  15. American Society for Testing and Materials, “ASTM D348-00”, Standard Test Methods for Rigid Tubes Used for Electrical Insulation

  16. American Society for Testing and Materials, “ASTM D790-03”, Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials p. 6

  17. American Society for Testing and Materials, “ASTM E2207–02”, Standard Practice for Strain-Controlled Axial-Torsional Fatigue Testing with Thin-walled Tubular Specimens

  18. O. H. BASQUIN, in “Proceedings of the American Society for Testing and Materials”, Vol 10 (1910)

  19. International Standard Organization, “ISO7206–4”, Implants for Surgery-Partial and Total Hip Joint Prostheses-Part 4: Determination of Endurance Properties of Stemmed Femoral Components

  20. American Society for Testing and Materials, “ASTM F1612–95”, Standard Practice For Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components with Torsion

  21. M. N. BUREAU and J. DENAULT, Comp. Sci. Tech. 64 (2004) 1785

    Article  CAS  Google Scholar 

  22. D. C. WIRTZ, N. SCHIFFERS, T. PANDORF, K. RADERMACHER, D. WEICHERT and R. FORST, J. Biomech. 33 (2000) 1325

    Article  CAS  Google Scholar 

  23. D. T. REILLY and A. H. BURSTEIN, J. Biomech. 8(6) (1975) 393

    Article  CAS  Google Scholar 

  24. D. T. REILLY, A. H. BURSTEIN and V. H. FRANKEL, J. Biomech. 7(3) (1974) 271

    Article  CAS  Google Scholar 

  25. S. M. SNYDER and E. SCHNEIDER, J. Orthop. Res. 9 (1991) 422

    Article  CAS  Google Scholar 

  26. H. B. SKINNER, Orthopedics 14(3) (1991) 323

    CAS  Google Scholar 

  27. G. BERGMANN, F. GRAICHEN and A. ROHLMANN, J. Biomech. 26(8) (1993) 969

    Article  CAS  Google Scholar 

  28. American Society for Testing and Materials, “ASTM F1440–92”, Standard Practice for Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components Without Torsion

Download references

Acknowledgments

The collaboration of Terray Corporation for financial participation and for providing materials as well as the financial support of project by NSERC (STP 306867-04) and the National Research Council of Canada are gratefully acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Martin N. Bureau.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Campbell, M., Bureau, M.N. & Yahia, L. Performance of CF/PA12 composite femoral stems. J Mater Sci: Mater Med 19, 683–693 (2008). https://doi.org/10.1007/s10856-007-3073-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10856-007-3073-y

Keywords

Navigation